Hv ABC Cable, Aerial Bundled Cable, Al/XLPE/Cws/HDPE+Gsw, 3/C+1/C, 6.35/11 Kv (AS/NZS 3599.1)
Hv ABC Cable, Aerial Bundled Cable, Al/XLPE/Cws/HDPE+Gsw, 3/C+1/C, 6.35/11 Kv (AS/NZS 3599.1) image
Get Latest Price Request a quote
Quick Details
Product Details
Metallic Screened HV ABC
Conductors
Phase conductors are stranded circular compacted aluminium alloy 1350 to H68 condition. The standard catenary is manufactured from galvanised stranded high tensile steel. For corrosive environments catenaries of aluminium clad steel are available.
Conductor Screen, Insulation and Insulation Screen
Semiconductive conductor screen, XLPE insulation and semiconductive insulation screen are triple extruded. The insulation screen is hand strippable without preheating and complies with strippability and adhesion tests given in AS/NZS 3599.1. Figures and words "1 ONE," "2 TWO" and "3 THREE" are printed on the insulation screen to identify the three phase cores. Alternative identification means are available on request.
A water swellable textile tape is applied over the insulation screen to prevent longitudinal ingress of moisture in the event of damage to the outer sheath.
Metallic Screen
The metallic screen comprises a layer of helically applied copper wires. For short circuit protection, two types of screens, a light and a heavy duty, are available. A separator tape to prevent the penetration of sheath material between the screen wires is applied over the metallic screen. On this design of cable it should be noted that the screens of individual cores are not in direct contact with each other and therefore the fault current level is limited.
Sheath
High density polyethylene (HDPE) is used as the standard outer sheath of each phase core. In addition to the identification on the cores, the sheaths of each phase cable are marked with phase numbers matching those of the cores.
The cable bundle
The three single core cables are bundled around the galvanised steel catenary in a right hand lay.
Operating temperature
(a) Normal operation 90°C
(b) Emergency operation 105°C
(c) Short circuit operation 250°C (5s max)
This cable can be used for aerial as well as underground installations.
| AS/NZS-3599.1 | |||||||
| HV XLPE Insulated Metallic Screend ABC 6.35/11 KV | |||||||
| Nominal Conductor Area | Average Insulation Thickness | Average Insulation Screen Thickness | Copper Wire Screen Thickness | Galvanised Steel Catenary stranding | Nominal Overall Diameter | Approx. Mass | DC Resistance at 20°C |
| mm2 | mm | mm | no/mm | no | mm | kg/km | Ω/km |
| 35 | 3.4 | 0.8 | 24/0.85 | 7 | 53.1 | 1760 | 0.868 |
| 35 | 3.4 | 0.8 | 24/0.85 | 19 | 57.1 | 2060 | 0.868 |
| 50 | 3.4 | 0.8 | 24/0.85 | 19 | 59.3 | 2230 | 0.641 |
| 70 | 3.4 | 0.8 | 24/0.85 | 19 | 62.5 | 2500 | 0.443 |
| 95 | 3.4 | 0.8 | 24/0.85 | 19 | 66.0 | 2820 | 0.320 |
| 120 | 3.4 | 0.8 | 24/0.85 | 19 | 58.8 | 3100 | 0.253 |
| 150 | 3.4 | 0.8 | 24/0.85 | 19 | 72.0 | 3440 | 0.206 |
| 185 | 3.4 | 0.8 | 24/0.85 | 19 | 75.0 | 3800 | 0.164 |
| 35 | 3.4 | 0.8 | 40/0.85 | 7 | 53.1 | 2020 | 0.868 |
| 35 | 3.4 | 0.8 | 40/0.85 | 19 | 57.1 | 2310 | 0.868 |
| 50 | 3.4 | 0.8 | 23/1.35 | 19 | 61.3 | 2790 | 0.641 |
| 70 | 3.4 | 0.8 | 32/1.35 | 19 | 64.5 | 3420 | 0.443 |
| 95 | 3.4 | 0.8 | 38/1.35 | 19 | 68.0 | 3980 | 0.320 |
| 120 | 3.4 | 0.8 | 38/1.35 | 19 | 70.8 | 4270 | 0.253 |
| 150 | 3.4 | 0.8 | 38/1.35 | 19 | 74.0 | 4600 | 0.206 |
| 185 | 3.4 | 0.8 | 38/1.35 | 19 | 77.0 | 4960 | 0.164 |
| Galvanised Steel Catenaries | |||||||
| Units | |||||||
| Stranding & Nom. Wire Dia. | no/mm | 7/2.00 | 19/2.00 | ||||
| Nominal Overall Diameter | mm | 6.0 | 10.0 | ||||
| DC Resistance at 20°C | Ω/km | 8.7 | 3.2 | ||||
| Minimum Breaking Load | kN | 26.0 | 70.5 | ||||
We are China Hv ABC Cable, Aerial Bundled Cable, Al/XLPE/Cws/HDPE+Gsw, 3/C+1/C, 6.35/11 Kv (AS/NZS 3599.1) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Overhead ABC XLPE/PVC Insulated Cable Aerial Bundle Cable Aluminum ABC Electric Power Cable
4X35mm2 Al Core PE/XLPE/PVC Insulation Overhead ABC Cable 0.6kv
0.6 / 1kv XLPE Insulated Overhead Electric Transmission Aerial Bundle Cable
5kv/10kv/15kv/25kv/35kv 11kv/22kv/33kv Medium Voltage Mv ABC Cable
Triplex ASTM Standard Oyster 4-7 Aluminum AAC Core XLPE/PE Insulated Aerial Cable
Popular boancable Products
Ysly-Oz Control Cable, 300/500 V, Flexible Cu/PVC/PVC (VDE 0281-13)
Al Xhhw-2, Building Wire, 600 V, Al/XLPE (UL44/ICEA S-95-658/NEMA WC70)
Tfxp, Al/XLPE/Hpde/PVC, Underground Cable, 0.6/1kv, HD 603.5m
AAAC Conductor, All Aluminium Alloy Conductor (BS 3242)
Acar, Aluminum Conductor Aluminum Reinforced (ASTM B 524)
N07V-K, 450/750 V, Class 5 Cu/PVC Cable (CEI 20/22-2/EN 50267-2-1)
Popular Overhead Cable Products
AC Power Cord Cable Overhead Insulated Service Drop Cable
Low Voltage 0.6/1 Kv ABC Cable 4X95+2X25mm2 PE Insulation
All Aluminum Alloy Cable, ACSR (ALUMINIUM CONDUCTORS STEEL REINFORCED) Cable
Factory Outlet Duplex/Triplex Service Drop Overhead Aluminum Cable
450/750 Flexible PVC Control Cable
AAAC Aluminum Alloy Bare Oveahead Conductor
Popular Power Cable Products
Cable Bt Alu Isole 3X120+70 mm2 U1000 R2V Power Cable
BS Standard 95/55mm2 ACSR Conductor
12/20kv Alluminio Cavo Are4h5e (X) Mv Underground Power Cable
Single Core Power Cable 1*300mm2 Copper Electrical Power Cable
Cooper Conductor UV Resistant XLPE Cable 3X95mm2 3X120mm 3X240mm Low Voltage XLPE Underground Cable
Tags: ABC Cable, boancable, Overhead Cable, Power Cable