Hv Mv LV Heat Shrinkable Cable Joint Termination Kits

China 
                Hv Mv LV Heat Shrinkable Cable Joint Termination Kits
              manufacture and supplier

Hv Mv LV Heat Shrinkable Cable Joint Termination Kits image

Get Latest Price Request a quote

  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Recommended Product
  • Company Profile
  • Packaging & Shipping
  • FAQ

Overview

Basic Info.

Model NO.
VSZ

Usage
Cable Joint

Material
PE

Type
1~5-Cores

Partial Discharge
Pass

Standard
GB811-P5

Voltage Class
LV & Mv (up to 35kv)

Temperature
-50°c ~105°c

Transport Package
Carton

Specification
Varous

Trademark
9V

Origin
Jiangsu, China

HS Code
8547909000

Packaging & Delivery

Package Size
67.00cm * 17.00cm * 22.00cm

Package Gross Weight
9.000kg

Product Description

Product Description

Heat-shrinkable cable terminals
It commonly known as heat-shrinkable cable heads, are widely used on the terminals of cross-linked cables or oil-immersed cables with voltage levels of 35KV and below. Compared with the traditional cable accessories, the intermediate connection of the cable has the characteristics of small size, light weight, safety and reliability, and convenient installation.

Detailed Photos

 

Product Parameters

0.6/1KV-Heat Shrinkable Cable Accessories

Name Item No. Suit cables’ sectional area (sqmm) Name Item No. Suit cables’ sectional area (sqmm)
0.6/1kV Single Core Heat Shrinkable Termination Kits VSZ-1/1.0 10~16 0.6/1kV Single Core Heat Shrinkable Joint VSJ-1/1.0 10~16
VSZ-1/1.1 25~50 VSJ-1/1.1 25~50
VSZ-1/1.2 70~120 VSJ-1/1.2 70~120
VSZ-1/1.3 150~240 VSJ-1/1.3 150~240
VSZ-1/1.4 300~400 VSJ-1/1.4 300~400
0.6/1kV 2-cores Heat Shrinkable Termination Kits VSZ-1/2.0 10~16 0.6/1kV 2-cores Heat Shrinkable Joint VSJ-1/2.0 10~16
VSZ-1/2.1 25~50 VSJ-1/2.1 25~50
VSZ-1/2.2 70~120 VSJ-1/2.2 70~120
VSZ-1/2.3 150~240 VSJ-1/2.3 150~240
VSZ-1/2.4 300~400 VSJ-1/2.4 300~400
0.6/1kV 3-cores Heat Shrinkable Termination Kits VSZ-1/3.0 10~16 0.6/1kV 3-cores Heat Shrinkable Joint VSJ-1/3.0 10~16
VSZ-1/3.1 25~50 VSJ-1/3.1 25~50
VSZ-1/3.2 70~120 VSJ-1/3.2 70~120
VSZ-1/3.3 150~240 VSJ-1/3.3 150~240
VSZ-1/3.4 300~400 VSJ-1/3.4 300~400
0.6/1kV 4-cores Heat Shrinkable Termination Kits VSZ-1/4.0 10~16 0.6/1kV 4-cores Heat Shrinkable Joint VSJ-1/4.0 10~16
VSZ-1/4.1 25~50 VSJ-1/4.1 25~50
VSZ-1/4.2 70~120 VSJ-1/4.2 70~120
VSZ-1/4.3 150~240 VSJ-1/4.3 150~240
VSZ-1/4.4 300~400 VSJ-1/4.4 300~400
0.6/1kV 5-cores Heat Shrinkable Termination Kits VSZ-1/5.0 10~16 0.6/1kV 5-cores Heat Shrinkable Joint VSJ-1/5.0 10~16
VSZ-1/5.1 25~50 VSJ-1/5.1 25~50
VSZ-1/5.2 70~120 VSJ-1/5.2 70~120
VSZ-1/5.3 150~240 VSJ-1/5.3 150~240
VSZ-1/5.4 300~400 VSJ-1/5.4 300~400
Test Project Test Method Test Result/Conclusion
1min Power Frequency Voltage (wet state) 4kV, No breakdown no flashover No flashover and breakdown of the combined sample under 4kV, 1min wet state
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
4H Power Frequency Voltage Test 2.4kV, No breakdown no flashover No flashover and breakdown of combined specimens

8.7/15KV-Heat Shrinkable Cable Accessories

Name Item No. Suit cables’ sectional area (sqmm) Name Item No. Suit cables’ sectional area (sqmm)
8.7/15kV Single Core Heat Shrinkable Indoor Termination Kits VRSN-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Indoor Termination Kits VRSN-10/3.1 25~50
VRSN-10/1.2 70~120 VRSN-10/3.2 70~120
VRSN-10/1.3 150~240 VRSN-10/3.3 150~240
VRSN-10/1.4 300~400 VRSN-10/3.4 300~400
VRSN-10/1.5 500~630 VRSN-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Outdoor Termination Kits VRSW-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-10/3.1 25~50
VRSW-10/1.2 70~120 VRSW-10/3.2 70~120
VRSW-10/1.3 150~240 VRSW-10/3.3 150~240
VRSW-10/1.4 300~400 VRSW-10/3.4 300~400
VRSW-10/1.5 500~630 VRSW-10/3.5 500~630
8.7/15kV Single Core Heat Shrinkable Joint VRSJ-10/1.1 25~50 8.7/15kV 3-cores Heat Shrinkable Joint VRSJ-10/3.1 25~50
VRSJ-10/1.2 70~120 VRSJ-10/3.2 70~120
VRSJ-10/1.3 150~240 VRSJ-10/3.3 150~240
VRSJ-10/1.4 300~400 VRSJ-10/3.4 300~400
VRSJ-10/1.5 500~630 VRSJ-10/3.5 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 45kV, No breakdown no flashover No flashover and breakdown of the combined sample under 45kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 13kV≤20PC A, B, C three-phase discharge capacity is 2PC under 13kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 105kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 105kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 52kV, No breakdown no flashover 52kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 35kV, No breakdown no flashover 35kV, 4h, No flashover and breakdown of combined specimens

12/20KV 18/20KV-Heat Shrinkable Cable Accessories

 

Name Spec. (Single Core) Spec. (3-cores) Suit cables’ sectional area (sqmm)
12/20kV 18/20kV
12/20kV Single Core / 3-cores Heat Shrinkable Indoor Termination Kits VRSN-20/1.1 VRSN-20/3.1 35~70 ——
VRSN-20/1.2 VRSN-20/3.2 95~185 35~70
VRSN-20/1.3 VRSN-20/3.3 240~400 95~185
VRSN-20/1.4 VRSN-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores Heat Shrinkable Outdoor Termination Kits VRSW-20/1.1 VRSW-20/3.1 35~70 ——
VRSW-20/1.2 VRSW-20/3.2 95~185 35~70
VRSW-20/1.3 VRSW-20/3.3 240~400 95~185
VRSW-20/1.4 VRSW-20/3.4 500~630 240~400
12/20kV Single Core / 3-cores  Heat Shrinkable Joint VRSJ-20/1.1 VRSJ-20/3.1 35~70 ——
VRSJ-20/1.2 VRSJ-20/3.2 95~185 35~70
VRSJ-20/1.3 VRSJ-20/3.3 240~400 95~185
VRSJ-20/1.4 VRSJ-20/3.4 500~630 240~400
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 54kV, No breakdown no flashover No flashover and breakdown of the combined sample under 54kV, 1min wet state
Partial discharge test 13kV devolution power not more than 20PC 20kV≤20PC A, B, C three-phase discharge capacity is 1pc under 20kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 125kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 125kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens

 

26/35KV-Heat Shrinkable Cable Accessories

Name Item No. Suit cables’ sectional area (sqmm) Name Item No. Suit cables’ sectional area (sqmm)
26/35kV Single Core Heat Shrinkable Indoor Termination Kits VRLN-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Indoor Termination Kits VRLN-35/3.1 50~95
VRLN-35/1.2 120~185 VRLN-35/3.2 120~185
VRLN-35/1.3 240~400 VRLN-35/3.3 240~400
VRLN-35/1.4 500~630 VRLN-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Outdoor Termination Kits VRLW-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Outdoor Termination Kits VRLW-35/3.1 50~95
VRLW-35/1.2 120~185 VRLW-35/3.2 120~185
VRLW-35/1.3 240~400 VRLW-35/3.3 240~400
VRLW-35/1.4 500~630 VRLW-35/3.4 500~630
26/35kV Single Core Heat Shrinkable Joint VRLJ-35/1.1 50~95 26/35kV 3-cores Heat Shrinkable Joint VRLJ-35/3.1 50~95
VRLJ-35/1.2 120~185 VRLJ-35/3.2 120~185
VRLJ-35/1.3 240~400 VRLJ-35/3.3 240~400
VRLJ-35/1.4 500~630 VRLJ-35/3.4 500~630
Test Project Standard Requirements Test Result/Conclusion
1min Power Frequency Voltage (wet state) 105kV, No breakdown no flashover No flashover and breakdown of the combined sample under 105kV, 1min wet state
Partial discharge test 13kV devolution power not more than 10PC 39kV≤10PC A, B, C three-phase discharge capacity is 4pc under 39kV
Heating Cycles Voltage Test Conductor heating to 90-95 ºC, each cycle for 8h, including heating 5h, cooling 3h, a total of three cycles Complete three load cycle tests as required by the standard
Impulse Voltage Test 250kV positive and negative polarity 10 times each, no flashover and breakdown of the combined specimen 250kV positive and negative polarity 10 times each, no flashover and breakdown
Negative Polarity DC Voltage Test 156kV, No breakdown no flashover 156kV, 15min, No flashover and breakdown of combined specimens
4H Power Frequency Voltage Test 104kV, No breakdown no flashover 104kV, 4h, No flashover and breakdown of combined specimens

 

Recommended Product

View more products,you can click photos…

     66~500kV High Voltage Cable Accessories              1~35kV Cold Shrink Cable Accessories                                        Grounding Box

      Customized Silicone Rubber Protector                                Heat Shrinkable Tubing                                                  Explosion Proof Box

Company Profile

Packaging & Shipping

FAQ

/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Hv Mv LV Heat Shrinkable Cable Joint Termination Kits manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Heat Shrink Joint Products

High Standard Heat Shrinkable 3-Core Cable Straight Joint Kit

Low Voltage 10kv Heat Shrinkable Straight Joint Kit

20kv Cable Termination Heat Shrinkable Straight Through Joint

3 Core 20kv Heat Shrinkable Accessories Outdoor Cable Termination Kit

Indoor and Outdoor 10kv Heat Shrinkable Cable Termination Kit

Factory Direct Supply 10kv Heat Shrinkable Cable Termination Kit

Popular Heat Shrink Joint Kit Products

Heat Shrinkable Termination Kits Straight Through Cable Joints

10kv 3-Core Heat Shrinkable Outdoor Cable Insulation Termination Kit

1~35kv Outdoor Heat Shrinkable Cable Straight Joint Kits

10/15kv Silicone Rubber Cold Shrink Cable Termination and Joint

9V Straight Through Joint with Copper Shell

Professional Manufacturer Heat Shrinkagle XLPE Cable Jointing Kits

Popular Hv Mv LV Heat Shrinkable Cable Joint Termination Kits Products

  • No related articles
  • Popular jiuweielectric Products

    High Standard Communication Cold Shrinkable Tube Professional Manufacturer EPDM Cold Shrink Tubing

    Factory Supply High Rate Cold Shrink Tube for Cable

    Silicone Rubber Cold Shrinkable Sleeve Waterproof Vtxg Cold Shrink Tube

    Excellent Heat Shrinking Cable Breakout Boots

    Yellow-Green Heat Shrinkable Busbar Sleeve Flame-Retardant Cable Protection Sleeve

    Vfsm-4 φ 25/8.5-68 Heat Shrinkable End Caps Sealing Caps

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION