Hv Removable Isolating Links

China 
                        Hv Removable Isolating Links
                      manufacture and supplier

Hv Removable Isolating Links image

Get Latest Price Request a quote

Quick Details

Hv Removable Isolating Links

22KV

Oei Power

IEC IEEE

Manual

Ist

Turn the Horizontal

Three

Single Ground

Three Pole

Horizontal Rotary Type

Grounding

Manual

Outdoor High-voltage

Three-column Disconnector

High-voltage

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

8535309000

Product Details

The following documents were referred to during the preparation of this specification. In case of conflict, the provisions of this specification shall take precedence.
IEC 129:1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694:2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.

SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30ºC with a minimum of -1ºC and a maximum of +40ºC and heavy saline conditions along the coast.

4.2. DESIGN AND CONSTRUCTION
4.2.1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2.2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2.3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2.4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2.5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2.6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2.7 The solid link shall be removable from the mounting by use of operating rod.
4.2.8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2.9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.

The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
 

S.No DESCRIPTION UNITS BIDDER OFFERED VALUE
1. Rated Voltage KV 12 KV
2. Frequency Hz 50 Hz
3 Rated continuous current A 630
4 Impulse withstand voltage to ground KV 95
5 Impulse withstand voltage across gaps KV 110
6 Dry one-minute power frequency withstand voltage to ground KV 35
 
7 Dry one minute power frequency withstand voltage across gap KV 45
8 Wet one minute power frequency withstand voltage to ground      KV 30
9 Limits of radio interference 10KV  and 1000 K.C/Sec   250  uV
10 Temperature rise at rated current (max.)        30oC at 50oC ambient
11 Dimensions and mechanical ,Electrical
values Of Polymer Insulator
   
12 Leaking distance  mm      508 (minimum)
13 Dry arcing distance    mm 210 (minimum)
14 Cantilever strength     kg 400 
15 Tensile strength kg 1000
16 Compressive strength  kg 5400
17 Tensile proof test load      kg 700
18 Dry power frequency flashover      KV 85 
19 Wet power frequency flashover      KV 55 
20 Dry one-minute power frequency withstand KV 70
21 Wet one-minute power frequency withstand KV 45
22 Impulse flash over positive      KV 115 
23 Impulse flashover negative      KV 140
24 Power frequency puncture voltage  KV 150  

We are China Hv Removable Isolating Links manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Disconnector Switch Products

Iacm 24kv 50A 3 Phase Outdoor Switch Disconnector

High Quality Pin Type Porcelain Insulators for High Voltage

24kv Load Isolators

Railway Solid-Core Porcelain Station Glass Insulator

High Voltage Indoor Isolator Disconnector Isolated Switch

33kv Air Break Switch

Popular Isolating Switch Products

Gw9-12kv Outdoor Disconnect Switch Isolating Break Switch

3 Phase Three Column Disconnector Gw9

IP66 1p 35A 500V Combination Changeover Rotary Isolating Switch

12kv Isolating Switch Gang Insulator Porcelain Cutout Fuse Ceramic Dropout Fuse Fuse Cutout Gang Insulator Isolating Switch 15kv 22kv 36kv Silicon Composite

11kv Isolating Switch Gang Insulator Composite Cutout Fuse Ceramic Dropout Fuse

Ukf3-63 63A Wenzhou Factory Price Isolator Swith with Silver Contact

Popular jgtrade1 Products

Polyester Lined Glove Coated with PU (black)

Hkgwf-36 35kv Disconnector Switch 33kv Isolators Disconnect

Flexible Terminal Connectors for Tubular Bus-Bar Type Mds, Group C

High -Voltage Isolate Switch 12kv

Wedge Connector

Power Distribution Cabinet

Popular Switch Disconnector Products

33kv 630A Load Isolators High Voltage

Single Polecircuitbreaker (63A) Suitable Forpolemountedsplitmeters

High -Voltage Isolate Switch 12kv 600A

12kv Load Isolators

High Voltage Switch Disconnector Series Gw9-15

Disconnector Switch 40.5kv

Tags: , , ,