Hy5wbg Outdoor 10kv Line Pillar Zinc Oxidedistribution Line Arresters with Bracket No Gap Discharge
Hy5wbg Outdoor 10kv Line Pillar Zinc Oxidedistribution Line Arresters with Bracket No Gap Discharge image
Get Latest Price Request a quote
Basic Info.
Product Description
Product Description
At present, the process of overhead insulation below 10KV in urban and rural areas is very fast. However, in the distribution transformer area on the pole, there are many connection parts such as switches, arresters, connecting clips, and pillars, which bring many operating fault points, poor insulation and safety protection conditions, complicated installation and maintenance. There are a series of problems such as difficulty, high cost, and poor live working conditions. In order to deal with the above problems, it is necessary to transform some equipment and line connection methods of the distribution transformer system on the pole, so that it can achieve the purpose of simplifying the device and further increasing the operation safety. HY5WBG type synthetic jacketed zinc oxide arrester device has the function of strut, arrester, puncture and electrification, and grounding function. It has a multi-purpose structure. The use of this device can also reduce one arrester cross-arm (because of the use of the originally required pillar cross-arm), can reduce the three insulators used for fixing the sag, that is, seven peeling points, reduce construction time, and reduce six If the fault point is located, the purpose of simplifying the line device, further increasing the safety and reliability of operation, and making the line more concise and beautiful. This device integrates a variety of functions, and insulates the insulation that originally required seven peeling points into one.The design of the shield is reasonable and can truly achieve the whole insulation, creating favorable conditions for safety and live operation
Model Description
Product technical parameters
Product installation effect and production process
Product Structural features and scope of use
1. The core body and jacket of the arrester are molded into a compact whole without a cavity, which eliminates the moisture absorption caused by breathing and fundamentally eliminates the accident caused by the damping of the arrester chip.
2. The inside of the arrester adopts a special strengthening structure, which makes it have good mechanical properties and can also be used as an insulator
3. The synthetic jacket of the arrester is made of silicone rubber material, which makes it have strong anti-pollution performance and good explosion-proof performance. In addition, light weight and long service life
4. The arresters are designed and produced according to the class III heavy pollution resistance. The minimum creepage ratio of the insulating jacket is 25mm/KV, and the creepage distance is 320mm.
5. The overall structure of the arrester is optimized and has a combined function.
a. It has both grounding stems, which can meet the needs of electricity inspection and grounding, and can simplify the tower installation
b. The special reinforcement structure makes it have good mechanical properties and can double as a pillar insulator
c. The connection terminal block can segment the cable fault, reduce the power failure range, and has the function of breaking the knife switch
d. The use of full insulation design can effectively avoid the occurrence of accidents such as external force damage
6. The arrester device has the function of supporting pillars, connecting terminal busbar wiring, and electrical inspection and grounding. The connecting terminal busbar can segment cable faults, reduce the scope of power outages, and has the function of segmenting a knife switch.
Product implementation standards and user notices
The production standard of the product is GB11032-2000 (eqv IEC60099-4:1991) “AC No-gap Metal Oxide Surge Arrester”, JB/8952-2005 “Composite Jacket No-gap Metal Oxide Surge Arrester for AC System”
1. The arrester should be stored in a clean and dry room before installation and use. Must not be corroded by corrosive gases or liquids.
2. Before the arrester is put into operation, a preventive test should be carried out. After being put into operation, it should also be regularly (10KV and below arrester once every 5 years, 35KV and above arrester once every 2 years)
Do the following test and compare with the data before operation with reference to the attached table:
a. Measure the insulation resistance of the arrester
b. Measure the DC 1mA voltage of the arrester
c. Measure the leakage current of 0.75 times DC 1mA
Product details
Products real shot
A corner of the production workshop
Product packaging
Product application case
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Hy5wbg Outdoor 10kv Line Pillar Zinc Oxidedistribution Line Arresters with Bracket No Gap Discharge manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnkcele Products
Mwl 63-125mm Outdoor Supports for Bar (Vertical setting) Substation Fitting
Zw7 40.5kv 1250A 1600A 2000A Outdoor Power Station Type Column Switch High Voltage Circuit Breaker
Jgw 40-165mm 1-3 Core High Voltage Cable Fixing Clamp Cable Hoop
Mrj 120-400mm² 19-33mm Spacers for Double Bus-Bar Conductor Electric Power Protective Fitting
Dfw Series 15/25kv 200/600A American Cable Branch Box
Popular Hy5wbg Outdoor 10kv Line Pillar Zinc Oxidedistribution Line Arresters with Bracket No Gap Discharge Products
Popular Lightning Arrester Products
33kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
6kv Polymeric Housed Metal-Oxide Lightning Arrester Without Gaps
110kv Silicon Type Surge Arrester Cma5wx-108/309
Surge Suppressor Lightning Arrester
15kv 66kv Antenna Surge Arrester Lightning Arrester Tester
Popular Puncture Lightning Arrester Products
Yh5ws 10kv 35kv High Voltage Compound Zinc Oxide Distribution Line Arresters
Yh5wz 35kv Zinc Oxide Distribution Line Arresters for High Voltage Power Station
Hy5 (10) W with Bracket Disconnector (Or Outlet) Composite Jacket Gapless Arrester Surge Arrester
Tags: cnkcele, Hy5wbg Outdoor 10kv Line Pillar Zinc Oxidedistribution Line Arresters with Bracket No Gap Discharge, Lightning Arrester, Puncture Lightning Arrester