Icea Approved Aluminum Conductor XLPE Insulated Wire ABC Cable
Icea Approved Aluminum Conductor XLPE Insulated Wire ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.
Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
Detaild Introduction of Service Drop Cable
1 Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
2 Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction: Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.
3 Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction: Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
Specification:
| Phase | Phase | Phase | Approx. Overall Diameter | Max. D. C. Resistance of Conductor at 20 Centigrade | |||
| AAC+UV-XLPE | Compact Conductor | UV-XLPE Insulation | |||||
| No. X Normal Cross Section of Cores | No. Of Al Wires | Overall Diameter | Normal Thickness | Min. | Diameter | ||
| No. X mm 2 | – | mm | mm | mm | mm | mm | Ohm/km |
| 1 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 6.05 | 3.08 |
| 1 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 7.20 | 1.91 |
| 1 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 8.40 | 1.20 |
| 1 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 9.80 | 0.868 |
| 1 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 11.10 | 0.641 |
| 1 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 12.60 | 0.443 |
| 1 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 14.80 | 0.320 |
| 1 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 16.20 | 0.253 |
| 1 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 18.20 | 0.206 |
| 1 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 20.20 | 0.164 |
| 1 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 22.80 | 0.125 |
| 2 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 12.10 | 3.08 |
| 2 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 14.40 | 1.91 |
| 2 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 16.80 | 1.20 |
| 2 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 19.60 | 0.868 |
| 2 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 22.20 | 0.641 |
| 2 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 25.20 | 0.443 |
| 2 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 29.60 | 0.320 |
| 2 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 32.40 | 0.253 |
| 2 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 36.40 | 0.206 |
| 2 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 40.40 | 0.164 |
| 2 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 45.60 | 0.125 |
| 3 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 13.07 | 3.08 |
| 3 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 15.55 | 1.91 |
| 3 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 18.14 | 1.20 |
| 3 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 21.17 | 0.868 |
| 3 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 23.98 | 0.641 |
| 3 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 27.22 | 0.443 |
| 3 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 31.97 | 0.320 |
| 3 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 34.99 | 0.253 |
| 3 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 39.31 | 0.206 |
| 3 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 43.63 | 0.164 |
| 3 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 49.25 | 0.125 |
| 4 X 10 | 7 | 4.05 | 1.0 | 0.8 | 6.05 | 14.64 | 3.08 |
| 4 X 16 | 7 | 4.8 | 1.2 | 0.98 | 7.2 | 17.42 | 1.91 |
| 4 X 25 | 7 | 6 | 1.2 | 0.98 | 8.4 | 20.33 | 1.20 |
| 4 X 35 | 7 | 7.0 | 1.4 | 1.16 | 9.8 | 23.72 | 0.868 |
| 4 X 50 | 7 | 8.3 | 1.4 | 1.16 | 11.1 | 26.86 | 0.641 |
| 4 X 70 | 19 | 9.8 | 1.4 | 1.16 | 12.6 | 30.49 | 0.443 |
| 4 X 95 | 19 | 11.6 | 1.6 | 1.34 | 14.8 | 35.82 | 0.320 |
| 4 X 120 | 19 | 13 | 1.6 | 1.34 | 16.2 | 39.20 | 0.253 |
| 4 X 150 | 19 | 14.6 | 1.8 | 1.52 | 18.2 | 44.04 | 0.206 |
| 4 X 185 | 36 | 16.2 | 2.0 | 1.70 | 20.2 | 48.88 | 0.164 |
| 4 X 240 | 36 | 18.4 | 2.2 | 1.88 | 22.8 | 55.18 | 0.125 |
Workshop:
Shipment:
Certification:
FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100, 000-sq. -FT. Building. In 2012, we operates in a new 666, 000 sq. Foot state-of-the-art facility in Xiaodian Industry Park., Xinxiang, Henan, China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor, such as AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ), such as Duplex, Triplex, Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4. Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America, Central America, North America, Europe, Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
We are China Icea Approved Aluminum Conductor XLPE Insulated Wire ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Duplex Service Drop ACSR Neutral Conductor Setter
Overhead Stranded Conductor ABC Cable with AAC ACSR AAAC Neutral Message
Aerial Bundle Cable for Overhead Transmission Cabo Al Quadruplex
0.6/1kv Insulated Aluminum Conductor 50mm2 ABC Cable
PVC Insulated Electric Cable Power Transmission ABC Cable
Direct Factory Price High Quality XLPE Insulated Best Sale Aerial ABC Cable
Popular Cable Products
Copper /Flexible /Power /Rubber Cable
ASTM/IEC/BS/DIN Standard Overhead Aluminium Alloy Conductor AAAC
AS/NZS 120mm Screened VSD/EMC Cable
Energy-Saving Aluminum Alloy Frequency Conversion Cable
ABC Cable (Aerial Bundled Cable)
Popular jpcable99 Products
Aluminium Conductor Armored Power Cable
4 Core 150mm2 Copper Conductor Cable XLPE Insulated Cable
Moose High Quality Bare ACSR Conductor
AAC (All Aluminium Conductor) 50mm2 /120mm2 /240mm2 Aluminium Stranded Conductor
Direct Manufacturer Supply ACSR Conductor BS Standard
Popular Power Cable Products
0.6/1kv 4 Core PVC Insulated and Sheathed Electric Copper Cable
Ht Cables cUL Certificate Power Armoured Aluminum Building Canada Standard Cable Acwu90
Medium Voltage XLPE Insulated PVC Sheathed Aluminum Conductor Electric Power Cable
Medium Voltage Copper Conductor Sta/Swa XLPE Insulated PVC Cable
3*120mm2 Medium Voltage Cu / XLPE /PVC N2xsy Cable
UL 15kv Medium Voltage Underground Power Cable 100% Insulation Level Copper XLPE 600mcm
Tags: ABC Cable, Cable, jpcable99, Power Cable