IEC 60227-4, DIN VDE Nvv, Nyy Power Cable

China 
                        IEC 60227-4, DIN VDE Nvv, Nyy Power Cable
                      manufacture and supplier

IEC 60227-4, DIN VDE Nvv, Nyy Power Cable image

Get Latest Price Request a quote

Quick Details

IEC 60227-4, DIN VDE Nvv, Nyy Power Cable

nyy

SABS, ISO9001-2008, CQC Certificate, CE, SGS

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen, Shenzh

L/C, D/P, D/a, T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

2000ton/Month

1km

Accord with The Request

Jiapu

Drum

CE SGS SABS

Henan, China

8544492100

Product Details

NVV, NYY Cable 

Standards: HRN HD 21.4 S2, IEC 60227-4, DIN VDE 0250 part 204
Construction
Conductor:
   bare copper conductor acc. to IEC 60228 / HD 383 / DIN VDE 0295
class 1:    solid (RE construction)
class 2:    multi wire stranded (RM construction)
Insulation:    PVC compound TI1 acc. to DIN VDE 0281 part 1 / HD 21.1 S4
Filler:     cores enveloped in non-vulcanized rubber or plastic compound
Sheath:    PVC compound TM1 acc. to DIN VDE 0281 part 1 / HD 21.1 S4
sheath colour:    grey (RAL 7035) 
during installationi:    +5 °C up to +70 °C
fixed installed:    -30 °C up to +70 °C
at short circuit of max. 5 s:    up to 150 °C
Nominal voltage:     U/U = 300/500 V
Ispitni napon:    2000 V
Minimal inner bending radius:    6D
Behaviour in fire:    IEC 60332-1
*) Construction: RE = single wire round conductor  RM = multi wire round conductor  
**) Packing: c.50 = coil 50 m, c.100 = coil 100 m, d.500 = drum 500 m

Workshop:

Shipment:

Specification:

Dimensions – number of cores x conductor cross-section Construction Construction of individual conductor External diameter Conductor resistance at 20 °C Specific. el. resistance of insulation at 70 C Short circuit current 1s Permited tensile load Cable weight Packing
    nominal min-max. max. min. nominal max. cca  
mm2   n x mm mm Ω/km MΩkm kA N kg/km  
1 x 1,5 RE 1 x 1,38 5,2 – 6,2 12,10 0,0100 0,17 75 45 CUT
1 x 2,5 RE 1 x 1,78 5,8 – 6,8 7,41 0,0094 0,29 125 70 CUT
1 x 4 RE 1 x 2,26 6,4 – 7,6 4,61 0,0087 0,46 200 80 CUT
1 x 6 RE 1 x 2,70 6,8 – 8,2 3,08 0,0074 0,69 300 105 CUT
1 x 10 RE 1 x 3,5 8,0 – 9,4 1,83 0,0072 1,15 500 155 CUT
1 x 16 RM 7 x 1,70 9,4 – 11,0 1,15 0,0053 1,84 800 230 CUT
1 x 25 RM 7 x 2,13 12,2 – 13,3 0,73 0,0051 2,88 1250 325 CUT
 
2 x 1,5 RE 1 x 1,38 8,4 – 9,8 12,10 0,0100 0,17 150 115 c.100
2 x 2,5 RE 1 x 1,78 9,6 – 11,0 7,41 0,0094 0,29 250 190 c.100
2 x 4 RE 1 x 2,26 11,0 – 12,5 4,61 0,0087 0,46 400 CUT
NVV cable
3 x 1,5 RE 1 x 1,38 8,8 – 10,5 12,10 0,0100 0,17 225 135 c.50, c.100
3 x 2,5 RE 1 x 1,78 10,0 – 11,5 7,41 0,0094 0,29 375 190 c.100, B500
3 x 4 RE 1 x 2,26 11,5 – 13,0 4,61 0,0087 0,46 600 265 CUT
3 x 6 RE 1 x 2,70 12,0 – 15,0 3,08 0,0074 0,69 900 315 CUT
3 x 10 RE 1 x 3,5 16,0 – 18,0 1,83 0,0072 1,15 1500 465 CUT
 
4 x 1,5 RE 1 x 1,38 9,5 – 11,0 12,10 0,0100 0,17 300 160 c.100
4 x 2,5 RE 1 x 1,78 11,0 – 12,5 7,41 0,0094 0,29 500 230 c.100
4 x 4 RE 1 x 2,26 12,5 – 14,5 4,61 0,0087 0,46 800 330 c.100, CUT
4 x 6 RE 1 x 2,70 14,5 – 16,5 3,08 0,0074 0,69 1200 460 c.50, CUT
4 x 10 RE 1 x 3,5 16,5 – 19,0 1,83 0,0072 1,15 2000 690 CUT
4 x 16 RM 7 x 1,70 20,5 – 23,5 1,15 0,0053 1,84 3200 1090 CUT
4 x 25 RM 7 x 2,13 25,0 – 28,5 0,73 0,0051 2,88 5000 1640 CUT
4 x 35 RM 7 x 2,52 27,5 – 32,0 0,52 0,0045 4,02 7000 2090 CUT
NVV cable
5 x 1,5 RE 1 x 1,38 9,9 – 12,0 12,10 0,0100 0,17 375 190 c.100, dr500
5 x 2,5 RE 1 x 1,78 11,5 – 13,5 7,41 0,0094 0,29 625 270 c.100, dr500
5 x 4 RE 1 x 2,26 14,0 – 16,5 4,61 0,0087 0,46 1000 410 c.100, CUT
5 x 6 RE 1 x 2,70 15,5 – 18,0 3,08 0,0074 0,69 1500 540 c.50, CUT
5 x 10 RE 1 x 3,5 18,0 – 21,0 1,83 0,0072 1,15 2500 850 CUT
5 x 10 RM 7 x 1,35 18,5 – 21,5 1,83 0,0065 1,15 2500 870 CUT
5 x 16 RM 7 x 1,70 22,5 – 26,0 1,15 0,0053 1,84 4000 1350 CUT
5 x 25 RM 7 x 2,13 27,5 – 31,5 0,73 0,0051 2,88 6250 1990 CUT
 
7 x 1,5 RE 1 x 1,38 11,0 – 13,0 12,10 0,0100 0,17 525 235 c.100, CUT
10 x 1,5 RE 1 x 1,38 13,9 – 15,6 12,10 0,0100 0,17 750 330 CUT
12 x 1,5 RE 1 x 1,38 14,2 – 16,1 12,10 0,0100 0,17 900 400 CUT
 
7 x 2,5 RE 1 x 1,78 12,7 -14,3 7,41 0,0094 0,29 875 350 CUT

Certification:

FAQ:
1. How many years has Henan Jiapu Cable Group been in production?

Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply. 

6. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?

For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.

 

We are China IEC 60227-4, DIN VDE Nvv, Nyy Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cable Products

High Voltage XLPE/PVC Insulated Electric Wire Power Cable IEC GB BS Standards

Power Cable 70mm2 120mm Low Voltage

Low Voltage Single/Two/Three-Core XLPE Insulated PVC Sheathed Power Cable

XLPE Insulated Aluminum/Copper Sta Armored PVC Sheath Electric Cable 150mm2

0.6/1kv Aluminum Conductor XLPE Insulation Caai Cable ABC Cable

High Quality 4X10mm2 Copper Core PVC Power Cable

Popular Electrical Wire Products

ASTM B232 Standard Overhead Aluminium Conductor Conductor ACSR Electrical Power Cable

BV Bvr BVV BVVB Rvs Cable Electrical Wire/Building Wire

Low Voltage Copper Wire

Copper Core Electric Wire 1.5mm 2.5mm 4mm 6mm

Factory Price Low Voltage XLPE Insulated PVC Shealth Armoured Power Cable for Underground

Electric Cable PVC Electric Wire Building Wire

Popular jpcable99 Products

ABC Cable/Aluminum Conductor Aerial Bundle Cable.

600/1000V 4 Core Copper Conductor XLPE Cable

ASTM Standard Aluminum Conductor Steel Reinforced Conductor (ACSR)

ACSR/Aw Aluminium Condutor Aluminium Clad Steel Wires

High Quality 4X10mm2 Copper Core PVC Power Cable

High Quality AAAC Overhead Conductor

Popular Nyy Products

Cables BT de distribution 4X70mm2 Cu Cuivre Type NYY PVC Insulated 0.6/1kV

Cu PVC PVC 4 Core PVC Nyy Nym Power Cable 35mm 50mm 95mm 120mm

Copper Conductor XLPE Insulated 0.4kV Power Cable 3X120+1X70mm2

Nyy 4 Core 120sqmm 0.6/1kv

Nyy Cable Nyy-J Cable Nyy-O Cable

NYY CU/PVC/PVC Service Cable for 11kV Distribution Network

Tags: , , ,