IEC 60502 Cable, XLPE Cables
IEC 60502 Cable, XLPE Cables image
Get Latest Price Request a quote
Quick Details
Product Details
IEC 60502 cable, XLPE cables
1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.
2.Construction
1)Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy,
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2)Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.
3)Colour Code
Colour Code (1)
1 Core | Red or Black |
2 Cores | Red, Black |
3 Cores | Red, Yellow, Blue |
4 Cores | Red, Yellow, Blue, Black |
5 Cores | Red, Yellow, Blue, Black, Green |
Above 5 Cores | Black Cores with White numerals |
Colour Code (2)
1 Core | Brown or Blue |
2 Cores | Brown, Blue |
3 Cores | Brown, Black, Grey |
4 Cores | Blue, Brown, Black, Grey |
5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
4)Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The material is compatible with the insulating material,
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with
the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
5)Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
6)Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7,
Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
7)Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Cable Parameters
1)Single core low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
1×1.5 | 1.4 | 0.7 | 1.4 | 5.6 |
1×2.5 | 1.8 | 0.7 | 1.4 | 6.0 |
1×4 | 2.3 | 0.7 | 1.4 | 6.5 |
1×6 | 2.8 | 0.7 | 1.4 | 7.0 |
1×10 | 3.6 | 0.7 | 1.4 | 7.8 |
1×16 | 4.5 | 0.7 | 1.4 | 8.7 |
1×25 | 5.6 | 0.9 | 1.4 | 10.2 |
1×35 | 6.7 | 0.9 | 1.4 | 11.3 |
1×50 | 8.0 | 1 | 1.4 | 12.8 |
1×70 | 9.4 | 1.1 | 1.4 | 14.4 |
1×95 | 11.0 | 1.1 | 1.5 | 16.1 |
1×120 | 12.4 | 1.2 | 1.5 | 17.8 |
1×150 | 13.8 | 1.4 | 1.6 | 19.8 |
1×185 | 15.3 | 1.6 | 1.6 | 21.8 |
1×240 | 17.5 | 1.7 | 1.7 | 24.4 |
1×300 | 19.5 | 1.8 | 1.8 | 26.7 |
1×400 | 22.6 | 2 | 1.9 | 30.5 |
1×500 | 25.2 | 2.2 | 2.0 | 33.7 |
1×630 | 28.3 | 2.4 | 2.2 | 37.4 |
1×800 | 31.9 | 2.6 | 2.3 | 41.7 |
1×1000 | 35.7 | 2.8 | 2.4 | 46.2 |
2)Two cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.8 | 9.2 |
2×2.5 | 1.8 | 0.7 | 1.8 | 10.0 |
2×4 | 2.3 | 0.7 | 1.8 | 11.0 |
2×6 | 2.8 | 0.7 | 1.8 | 12.0 |
2×10 | 3.6 | 0.7 | 1.8 | 13.6 |
2×16 | 4.5 | 0.7 | 1.8 | 15.4 |
2×25 | 5.6 | 0.9 | 1.8 | 18.4 |
2×35 | 6.7 | 0.9 | 1.8 | 20.6 |
2×50 | 8.0 | 1 | 1.8 | 23.6 |
2×70 | 9.4 | 1.1 | 1.8 | 26.8 |
2×95 | 11.0 | 1.1 | 1.9 | 30.2 |
2×120 | 12.4 | 1.2 | 2.0 | 33.7 |
2×150 | 13.8 | 1.4 | 2.2 | 37.5 |
2×185 | 15.3 | 1.6 | 2.3 | 41.6 |
2×240 | 17.5 | 1.7 | 2.5 | 46.7 |
2×300 | 19.5 | 1.8 | 2.6 | 51.4 |
2×400 | 22.6 | 2 | 2.9 | 58.9 |
3)Three cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.8 | 9.6 |
3×2.5 | 1.8 | 0.7 | 1.8 | 10.5 |
3×4 | 2.3 | 0.7 | 1.8 | 11.6 |
3×6 | 2.8 | 0.7 | 1.8 | 12.6 |
3×10 | 3.6 | 0.7 | 1.8 | 14.4 |
3×16 | 4.5 | 0.7 | 1.8 | 16.3 |
3×25 | 5.6 | 0.9 | 1.8 | 19.5 |
3×35 | 6.7 | 0.9 | 1.8 | 21.9 |
3×50 | 8.0 | 1 | 1.8 | 25.1 |
3×70 | 9.4 | 1.1 | 1.9 | 28.7 |
3×95 | 11.0 | 1.1 | 2.0 | 32.4 |
3×120 | 12.4 | 1.2 | 2.1 | 36.1 |
3×150 | 13.8 | 1.4 | 2.3 | 40.3 |
3×185 | 15.3 | 1.6 | 2.4 | 44.6 |
3×240 | 17.5 | 1.7 | 2.6 | 50.2 |
3×300 | 19.5 | 1.8 | 2.7 | 55.2 |
3×400 | 22.6 | 2 | 3.0 | 63.3 |
4)Three cores+1 low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1.8 | 17.5 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1.8 | 21.2 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1.8 | 23.8 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1.8 | 27.5 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 2.0 | 31.7 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 2.1 | 35.8 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 2.3 | 39.9 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 2.4 | 44.6 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 2.6 | 49.5 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 2.8 | 55.7 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 3.0 | 61.4 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 3.2 | 70.4 |
5)Four cores low voltage cables (unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.8 | 10.4 |
4×2.5 | 1.8 | 0.7 | 1.8 | 11.3 |
4×4 | 2.3 | 0.7 | 1.8 | 12.5 |
4×6 | 2.8 | 0.7 | 1.8 | 13.7 |
4×10 | 3.6 | 0.7 | 1.8 | 15.7 |
4×16 | 4.5 | 0.7 | 1.8 | 17.8 |
4×25 | 5.6 | 0.9 | 1.8 | 21.5 |
4×35 | 6.7 | 0.9 | 1.8 | 24.1 |
4×50 | 8.0 | 1 | 1.8 | 27.8 |
4×70 | 9.4 | 1.1 | 2.0 | 32.0 |
4×95 | 11.0 | 1.1 | 2.1 | 36.1 |
4×120 | 12.4 | 1.2 | 2.3 | 40.2 |
4×150 | 13.8 | 1.4 | 2.4 | 44.9 |
4×185 | 15.3 | 1.6 | 2.6 | 49.8 |
4×240 | 17.5 | 1.7 | 2.8 | 56.0 |
4×300 | 19.5 | 1.8 | 3.0 | 61.7 |
4×400 | 22.6 | 2 | 3.2 | 70.7 |
6)Multi-cores low voltage cables(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm |
5×1.5 | 1.4 | 0.7 | 1.8 | 11.2 |
7×1.5 | 1.4 | 0.7 | 1.8 | 12.0 |
10×1.5 | 1.4 | 0.7 | 1.8 | 14.8 |
12×1.5 | 1.4 | 0.7 | 1.8 | 15.2 |
14×1.5 | 1.4 | 0.7 | 1.8 | 16.0 |
19×1.5 | 1.4 | 0.7 | 1.8 | 17.6 |
21×1.5 | 1.4 | 0.7 | 1.8 | 18.4 |
24×1.5 | 1.4 | 0.7 | 1.8 | 20.4 |
30×1.5 | 1.4 | 0.7 | 1.8 | 21.6 |
40×1.5 | 1.4 | 0.7 | 1.8 | 26.0 |
48×1.5 | 1.4 | 0.7 | 1.8 | 26.4 |
61×1.5 | 1.4 | 0.7 | 1.9 | 29.0 |
5×2.5 | 1.8 | 0.7 | 1.8 | 12.2 |
7×2.5 | 1.8 | 0.7 | 1.8 | 13.2 |
10×2.5 | 1.8 | 0.7 | 1.8 | 16.4 |
12×2.5 | 1.8 | 0.7 | 1.8 | 16.9 |
14×2.5 | 1.8 | 0.7 | 1.8 | 17.7 |
19×2.5 | 1.8 | 0.7 | 1.8 | 19.6 |
21×2.5 | 1.8 | 0.7 | 1.8 | 20.6 |
24×2.5 | 1.8 | 0.7 | 1.8 | 22.8 |
30×2.5 | 1.8 | 0.7 | 1.8 | 24.1 |
40×2.5 | 1.8 | 0.7 | 1.9 | 29.4 |
48×2.5 | 1.8 | 0.7 | 1.9 | 29.9 |
61×2.5 | 1.8 | 0.7 | 2.0 | 32.8 |
7)Single core low voltage cables ( aluminum wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Alum Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
1×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 10.9 |
1×6 | 2.8 | 0.7 | 1.0 | 0.8 | 1.8 | 11.4 |
1×10 | 3.6 | 0.7 | 1.0 | 0.8 | 1.8 | 12.2 |
1×16 | 4.5 | 0.7 | 1.0 | 0.8 | 1.8 | 13.1 |
1×25 | 5.6 | 0.9 | 1.0 | 0.8 | 1.8 | 14.6 |
1×35 | 6.7 | 0.9 | 1.0 | 1.25 | 1.8 | 16.6 |
1×50 | 8.0 | 1 | 1.0 | 1.25 | 1.8 | 18.1 |
1×70 | 9.4 | 1.1 | 1.0 | 1.25 | 1.8 | 19.7 |
1×95 | 11.0 | 1.1 | 1.0 | 1.6 | 1.8 | 22.0 |
1×120 | 12.4 | 1.2 | 1.0 | 1.6 | 1.8 | 23.6 |
1×150 | 13.8 | 1.4 | 1.0 | 1.6 | 1.8 | 25.4 |
1×185 | 15.3 | 1.6 | 1.0 | 1.6 | 1.8 | 27.4 |
1×240 | 17.5 | 1.7 | 1.0 | 1.6 | 1.9 | 29.9 |
1×300 | 19.5 | 1.8 | 1.0 | 2.0 | 2.0 | 33.1 |
1×400 | 22.6 | 2 | 1.2 | 2.0 | 2.2 | 37.3 |
1×500 | 25.2 | 2.2 | 1.2 | 2.0 | 2.3 | 40. |
8)Two cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 12.8 |
2×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 13.6 |
2×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 14.6 |
2×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 16.5 |
2×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.1 |
2×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 19.9 |
2×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 23.6 |
2×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 25.8 |
2×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 29.0 |
2×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.0 | 33.2 |
2×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.1 | 37.1 |
2×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 40.5 |
2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.6 | 49.9 |
2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.7 | 55.1 |
2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 2.9 | 60.2 |
2×400 | 22.6 | 2 | 1.6 | 2.5 | 3.1 | 67.7 |
9)Three cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 13.2 |
3×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.1 |
3×4 | 2.3 | 0.7 | 1.0 | 0.8 | 1.8 | 15.2 |
3×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 17.1 |
3×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 18.9 |
3×16 | 4.5 | 0.7 | 1.0 | 1.25 | 1.8 | 20.8 |
3×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 24.7 |
3×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.8 | 27.2 |
3×50 | 8.0 | 1 | 1.0 | 1.6 | 1.9 | 30.6 |
3×70 | 9.4 | 1.1 | 1.0 | 2.0 | 2.1 | 35.2 |
3×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.2 | 39.3 |
3×120 | 12.4 | 1.2 | 1.2 | 2.0 | 2.3 | 43.0 |
3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53.0 |
3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.0 | 64.0 |
3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
10)Three cores+1 low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
mm^2 | (3) mm | (1) mm | (3) mm | (1) mm | mm | mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
3x 50/25 | 8.0 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
3x 95/50 | 11.0 | 8.0 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48.0 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
3×185/95 | 15.3 | 11.0 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 1.6 | 3.15 | 3.6 | 78.6 |
11)Four cores low voltage cables (Galvanized steel wire armoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
mm^2 | mm | mm | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.0 | 0.8 | 1.8 | 14.0 |
4×2.5 | 1.8 | 0.7 | 1.0 | 0.8 | 1.8 | 14.9 |
4×4 | 2.3 | 0.7 | 1.0 | 1.25 | 1.8 | 17.0 |
4×6 | 2.8 | 0.7 | 1.0 | 1.25 | 1.8 | 18.2 |
4×10 | 3.6 | 0.7 | 1.0 | 1.25 | 1.8 | 20.2 |
4×16 | 4.5 | 0.7 | 1.0 | 1.6 | 1.8 | 23.0 |
4×25 | 5.6 | 0.9 | 1.0 | 1.6 | 1.8 | 26.7 |
4×35 | 6.7 | 0.9 | 1.0 | 1.6 | 1.9 | 29.5 |
4×50 | 8.0 | 1 | 1.0 | 2.0 | 2.1 | 34.2 |
4×70 | 9.4 | 1.1 | 1.2 | 2.0 | 2.2 | 38.8 |
4×95 | 11.0 | 1.1 | 1.2 | 2.0 | 2.3 | 42.9 |
4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
We are China IEC 60502 Cable, XLPE Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular IEC 60502 Cable Products
Low and Medium Voltage Cu/Al Core Power Cable IEC60502 Standard
IEC 60502 3*185sq mm Copper Core XLPE Insulated Galvanized Steel Wire Armoured Low Voltage Cable
IEC 60502 PVC Insulated PVC Sheathed Cable for Electricity Transmission
Popular Low Voltage Cables Products
0, 6/1 Kv XLPE Insulated, Copper Tape Screened, Multi Core PVC Sheathed Armoured Cable
Electrical Wire PVC or XLPE Cover Electric Wire 3 Core Shielded Electrical Cable PVC Cable
Low Voltage and Medium Voltage Copper XLPE Insulated Underground Armored Type of Cables
Copper XLPE Insulation PVC Sheath Electric Electrical Power Wire Cable
Cu/XLPE/PVC Cable, Low Voltage Electric Cables
Popular luxingcable Products
Flat Electrical Wire Power Cable 4 Core Flat Electrical Wire
High Voltage XLPE Insulation Non-Magnetic Wire Armored Power Cable
Green Products Lsoh Color Power Cable 32AWG/30AWG/28AWG/26AWG/24AWG Low Voltage Bvr
Single or Twin Core 2.5mm Electrical Cable Power Cable Wire for Solar PV System
PVC Jacket and Copper Conductor Material Electric Wire Cable
Popular XLPE Cable Products
Low Voltage, 4core 240mm Power Cable, 4X240sqmm, 4c240sqmm
Rubber Sheath Flexible Cable (GB 5013-1997, JB 8735-1998)
33kv XLPE Cable with Good Quality and Competitive Price
Copper Conductor XLPE/PVC Insulated PE/PVC Sheathed Armored Electrical Power Cable
Waterproof Outdoor Fiber Optic Power Composite Cable/Power Cable
1-35kv Aluminum Core XLPE Insulated PE Sheathed Unarmoured Power Cable
Tags: IEC 60502 Cable, Low Voltage Cables, luxingcable, XLPE Cable