IEC 60502 Cu XLPE/PVC Insulated Swa PVC/PE Sheath Power Cable

IEC 60502 power Cable

Hongda

IEC 60502

ISO, CCC, CE, RoHS

Copper or Aluminum

Round Wire

PVC/PE

XLPE/PVC

AC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial

Yes

Yes

Multicores

Copper/Aluminum

as Your Requirement

Black

IEC 60502

10 Years

Swa/Awa

Hongda

Wooden Drum

35-1000mm2

China, Henan

8544492100

Product Details

 SWA/Cu/Al Conductor XLPE/PVC Insulated PVC/PE Sheath IEC 60502 Power Cable
IEC 60502 Cu XLPE/PVC Insulated Swa PVC/PE Sheath Power Cable
IEC 60502 Cable IEC60502-1 cable
power Cable CU/AL conductor  XLPE/PVC insulated PVC/PE sheath
International Standard IEC 60502-1 from the International Electrotechnical Commission sets out the specification for power cables with extruded insulation with a voltage rating of 1kV to 30kV. This standard also covers their accessories. The cables must have an extruded solid insulation and may contain longitudinal water-blocking properties such as swellable tapes and powders if the installation conditions demand it.
 
Many of the cables manufactured in accordance with IEC 60502 are designed for local power distribution, and for power and auxiliary controls. Where additional mechanical protection is provided, the cables are suitable for installation in masonry and concrete. The water-blocking properties are important to prevent water ingress when used in wet conditions.
IEC60502-2 cable 
It should be noted that IEC 60502-2 excludes cables for special conditions such as those manufactured for use in overhead lines, mining, nuclear power plants, marine and submarine applications. Where this is the case, technical specifications refer to cables being manufactured ‘Generally to IEC 60502-2’.

This Standard is divided into the following parts:

Parts Voltage Rating
1 1kV to 3kV
2 6kV to 30kV
3 Reserved for future development
4 Test requirements on accessories for cables with a voltage rating from 6kV to 30kV

Scope of IEC 60502-1
Part 1 of this international Standard specified the construction, dimensions and test requirements of cables with extruded solid insulation with a rated voltage ranging between 1kV and 3kV for fixed installations such as distribution networks or industrial installations. Some of the cables covered by IEC 60502 have flame spread-reducing or Low Smoke Zero Halogen (LSZH) properties when exposed to fire.
IEC 60502-1 Systems categories

Categories Operating conditions
A Systems in which any phase conductor that comes in contact with earth or an earth conductor is disconnected from the system within 1 minute
B Systems which, under fault conditions, are operated for a short time with one phase earthed (not exceeding 8hrs on any occasion and no more than 125hrs per annum)
C All systems which do not fall into category A or B

IEC 60502-1 Cable properties

Insulated compounds
Thermoplastic – intended for cables with voltage rating smaller or equal to 3kV
Polyvinly Chloride (PVC)
Thermosetting
Ethylene Propylene Rubber or similar (EPR or EPDM)
High modulus or hard grade ethylene propylene rubber (HEPR)
Cross-linked Polyethylene (XLPE)

 

Sheathing compounds
Thermoplastic
Polyvinyl Chloride (PVC)
Polyethylene (PE)
Halogen-Free
Elastomeric
Polychloroprene
Chlorosulphonated polyethylene
Polymers similar to above

 

Conductors
Class 1 or Class 2
Plain
Metal-coated annealed copper
Plain aluminium
Aluminium alloy
Class 5
Plain
Metal-coated copper according to IEC 60228

Some cables meeting the requirements of IEC 60502 benefit from armoured layers, making them able to withstand a higher degree of mechanical stress than comparative sized unarmoured cables. Various types of armour are specified, such as concentric copper wire screens and/or helically wound copper tape as required in the N2XCH cable.
 

Code-Designation for Power Cables with PVC or XLPE Insulation
Design Identification of Design Explanations
Conductor N According to VDE Standard
(No abbreviation for copper conductor)
A Aluminum conductors
Y Insulation of thermoplastic Polyvinyl chloride (PVC)
2X Insulation cross-linked Polyethylene (XLPE)
Concentric Conductor, Shielding C Concentric conductors of copper wires and copper tape, helically wounded
CW Concentric conductors of copper wires in wave conal formation and and copper tape, helically wounded
CE Concentric conductors of copper wires and copper tape over each individual conductor, helically wounded
Shielding S Shielding of copper wires and copper tape, helically wounded
SE Shielding of copper wires and copper tape over each individual conductor, helically wounded
(F) Longitudinally water-proof shielding
Armor B Armor of steel tape
F Armor of galvanized flat steel wires
G Counter helix of galvanized steel tape
Jacket K Lead jacket
Outer Jacket Y PVC jacket
2Y PE jacket
Cable for U0/U 0.6/1 kV are additionally designated with
  -J Cables with green-yellow (green-natural) conductor are marked with protective conductor
-O Cables without green-yellow (green-natural) conductor are marked without protective conductor

 

N MV cable according to DIN VDE 0276
A Aluminium (Al) conductor
[blank] Copper (Cu) conductor
2X Cross-linked polyethylene (XLPE) insulation
S Screen of copper wires and copper tape, helically wound
SE Screen of copper wires and copper tape over each individual core, helically wound
Y Polyvinyl Chloride (PVC) sheath
2Y Polyethylene (PE) sheath
(F)2Y Longitudinal water tightness with PE sheath
(FL)2Y Longitudinal and transversal water tightness with Al/PE sheath

 
Packaging&Delivery.

 

Packaging Details:Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 7 days(detailly depend on the order quantity)
Contact us

Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.Tel:+86 15039132763

We are China IEC 60502 Cu XLPE/PVC Insulated Swa PVC/PE Sheath Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cable Products

Copper Core Conductor Shield PVC Insulated Flexible Control Cable 10mm Electrical Wire

Flexible Copper 3 Core Shielded Power Cable

All Aluminum Alloy Conductor for Overhead Transmission Line

C22.2 No. 48 14AWG-2AWG 12AWG-2AWG Electric Cable Canadian House Wire with Good Service Nmd90

ASTM Standard Triplex Service Drop Cable XLPE Insulation ABC Cable

UL Listed 600V Copper Conductor PVC Insulated Nylon Jacket Thhn Cable

Popular IEC 60502 Products

Cu/XLPE/Lszh/Swa/Lszh, Power Cable, 0.6/1 Kv (BS 6724)

IEC 60502 BS Standard Electric Wire Cable

Al/XLPE/PVC/Sta/PVC, 0.6/1 Kv, Steel Tape Armored Power Cable (IEC 60502-1)

Popular Power Cable Products

Type Shd-Pcg, Mining Cable, Cu/Epr/CPE, 3/C, 2kv (ICEA S-75-381/NEMA WC-58)

1kv PVC Insulated Power Cable

Overhead Aluminum Conductor XLPE Insulation PVC Sheath Amoured Power Cable

Flex Cable Thn/Thhn/Thwn Wire Electrical Wire G/Y Wire

CU/XLPE/SWA/PE Electric Cables (8.7/15KV)

CU/XLPE/PVC Copper Insulated Underground Power Cable for 33/11kV Substation

Popular zzhongdacable Products

300mm2 Cable Three Phase Cable Underground Cable

2X10mm2 Concentric Service Cable with Communication Cores

XLPE Insulated PVC Sheathed 4c 35mm2 95mm PVC Power Cable

Low Voltage ABC Cable 1X16mm 2X16mm 3X35mm 4X35mm Overhead Power Cable

Twist Alu Cable Bt 2X16mm2 ABC Aerial Bundled Cable Overhead Lines

1*16+16+4*0.5mm2 1/0.8mm PE Insulated of Pilot 1.1mm Neutral Conductor Split Concentric Cables

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION