IEC/ASTM/BS/DIN Standard ACSR Conductor, Aluminium Conductor Steel Reinforced, Overhead Bare Aluminium Transmission Line.
IEC/ASTM/BS/DIN Standard ACSR Conductor, Aluminium Conductor Steel Reinforced, Overhead Bare Aluminium Transmission Line. image
Get Latest Price Request a quote
Quick Details
Product Details
Specification
1.Standard of ACSR
ACSR conductor can comply with IEC61089, ASTM B232, BS215, GB, DIN etc.
2.Construction of ACSR Conductor
According to IEC61089,cross section area of ACSR is from 16mm2 to 1250mm2, No of stranded aluminum wire and steel wire can be from Al6/1.84(mm)/Sr1/1.84 to Al84/4.35/Sr19/2.61.
3.Application & Characters of ACSR
Simple structure,convinent installation,lower cost,large transimission capacity,it is suitable for those special geographic conditions like the river,valley and mountain etc.
Antiseptic ACSR bears good antiseptic features,it is applied to coast area, salt sand area for ultra-high voltage, distribution transmission line. Antiseptic ACSR can be customize to put antiseptic materials among layers as customer’s expected.
Structure Parameter
No. | Size | Class | Stranding Design | Rated Strength (by type of steel core wire) | ||||
Aluminium/Steel | ACSR/GA | ACSR/GB | ACSR/GC | ACSR/HS | ACSR/AZ | |||
ACSR/MA | ACSR/MB | ACSR/MC | ACSR/MS | |||||
mm2 | kN | kN | kN | kN | kN | |||
1 | 1250 | AA | 84/19 | 306 | 300 | 293 | 319 | 289 |
2 | 1250 | AA | 76/19 | 269 | 265 | 260 | 278 | 260 |
3 | 1250 | AA | 72/7 | 250 | 246 | 242 | 257 | 239 |
4 | 1120 | AA | 84/19 | 275 | 269 | 263 | 286 | 259 |
5 | 1120 | AA | 46/19 | 240 | 236 | 232 | 248 | 232 |
6 | 1120 | AA | 72/7 | 226 | 223 | 219 | 232 | 218 |
7 | 1000 | AA | 84/19 | 245 | 239 | 234 | 254 | 231 |
8 | 1000 | AA | 72/7 | 202 | 199 | 196 | 208 | 195 |
9 | 900 | AA | 84/19 | 226 | 221 | 217 | 236 | 217 |
10 | 900 | AA | 72/7 | 181 | 179 | 176 | 186 | 175 |
11 | 800 | AA | 54/19 | 240 | 233 | 227 | 252 | 223 |
12 | 800 | AA | 45/7 | 186 | 182 | 179 | 193 | 175 |
13 | 710 | AA | 54/19 | 213 | 207 | 201 | 224 | 198 |
14 | 710 | AA | 45/7 | 167 | 164 | 160 | 173 | 158 |
15 | 630 | AA | 54/19 | 189 | 184 | 179 | 199 | 176 |
16 | 630 | AA | 45/7 | 148 | 145 | 142 | 153 | 140 |
17 | 560 | AA | 5419 | 173 | 168 | 164 | 182 | 164 |
18 | 560 | AA | 45/7 | 132 | 129 | 126 | 136 | 125 |
19 | 500 | AA | 54/7 | 154 | 150 | 145 | 163 | 141 |
20 | 500 | AA | 45/7 | 118 | 115 | 113 | 122 | 112 |
21 | 450 | AA | 54/7 | 139 | 135 | 131 | 147 | 128 |
22 | 450 | AA | 45/7 | 108 | 106 | 104 | 112 | 103 |
23 | 400 | AA | 30/19 | 170 | 164 | 158 | 181 | 155 |
24 | 400 | AA | 26/7 | 139 | 135 | 131 | 148 | 126 |
25 | 400 | AA | 54/7 | 123 | 120 | 116 | 130 | 113 |
26 | 355 | AA | 30/19 | 151 | 146 | 140 | 161 | 137 |
27 | 355 | AA | 26/7 | 123 | 119 | 115 | 131 | 112 |
28 | 355 | AA | 24/7 | 111 | 108 | 105 | 117 | 103 |
29 | 315 | AA | 30/19 | 138 | 133 | 128 | 147 | 128 |
30 | 315 | AA | 26/7 | 110 | 106 | 103 | 117 | 99.3 |
31 | 315 | AA | 24/7 | 98.7 | 96 | 93.2 | 104 | 91.7 |
32 | 315 | AA | 18/1 | 68 | 66.8 | 66.3 | 70.8 | 64 |
33 | 280 | AA | 30/7 | 122 | 118 | 113 | 131 | 109 |
34 | 280 | AA | 26/7 | 100 | 97.2 | 94.1 | 106 | 92.4 |
35 | 280 | AA | 24/7 | 87.5 | 85.1 | 82.6 | 92 | 81.2 |
36 | 280 | AA | 18/1 | 60.4 | 59.4 | 58.9 | 63 | 56.8 |
37 | 250 | AA | 30/7 | 109 | 105 | 101 | 117 | 97.4 |
38 | 250 | AA | 26/7 | 89.5 | 86.8 | 84.1 | 94.6 | 82.5 |
39 | 250 | AA | 24/7 | 79.4 | 77.2 | 75 | 83.4 | 73.8 |
40 | 250 | AA | 18/1 | 54.1 | 53.1 | 52.7 | 56.4 | 50.9 |
41 | 224 | AA | 30/7 | 97.4 | 93.9 | 90.4 | 104 | 86.9 |
42 | 224 | AA | 26/7 | 80 | 77.6 | 75.1 | 84.5 | 73.7 |
43 | 224 | AA | 24/7 | 72 | 70.1 | 68.1 | 74.8 | 68.1 |
44 | 224 | AA | 18/1 | 48.3 | 47.5 | 47.1 | 50.4 | 45.5 |
45 | 200 | AA | 30/7 | 89.7 | 86.6 | 83.4 | 95.5 | 81.6 |
46 | 200 | AA | 26/7 | 71.5 | 69.3 | 67.2 | 75.6 | 65.9 |
47 | 200 | AA | 24/7 | 64.2 | 62.5 | 60.7 | 67.7 | 60.7 |
48 | 200 | AA | 18/1 | 43.1 | 42.4 | 42.1 | 45 | 41.3 |
49 | 180 | AA | 30/7 | 80.7 | 77.9 | 75 | 85.9 | 73.4 |
50 | 180 | AA | 26/7 | 65.4 | 63.4 | 61.4 | 69 | 60.3 |
51 | 180 | AA | 24/7 | 57.8 | 56.2 | 54.7 | 60.9 | 54.7 |
52 | 180 | AA | 18/1 | 40.4 | 39.7 | 39.1 | 41.4 | 38.1 |
53 | 160 | AA | 30/7 | 72.9 | 70.4 | 67.9 | 77.6 | 66.4 |
54 | 160 | AA | 26/7 | 58.9 | 57.2 | 55.4 | 62.4 | 55.4 |
55 | 160 | AA | 24/7 | 52 | 50.6 | 49.2 | 54.8 | 49.2 |
56 | 160 | AA | 18/1 | 35.8 | 35.2 | 34.6 | 37 | 34 |
57 | 140 | AA | 26/7 | 52.2 | 50.7 | 49.2 | 55.3 | 49.2 |
58 | 140 | AA | 24/7 | 46.4 | 45.2 | 44 | 48.9 | 44 |
59 | 140 | AA | 18/1 | 31.5 | 30.9 | 30.4 | 32.5 | 29.9 |
60 | 125 | AA | 26/7 | 46.9 | 45.6 | 44.2 | 49.6 | 44.2 |
61 | 125 | AA | 24/7 | 41.5 | 40.4 | 39.3 | 43.6 | 39.3 |
62 | 125 | AA | 18/1 | 28.8 | 28.3 | 27.9 | 29.7 | 27.6 |
63 | 100 | AA(HS) | 16/19 | 123 | 117 | 111 | 133 | 106 |
64 | 100 | AA(HS) | 12/7 | 85.9 | 82 | 78 | 93.8 | 74.1 |
65 | 100 | AA,A | 6/1 | 34.6 | 33.5 | 33 | 37.3 | 30.8 |
66 | 90 | AA(HS) | 12/7 | 77.2 | 73.6 | 70.1 | 84.2 | 66.6 |
67 | 80 | AA(HS) | 12/7 | 70.6 | 67.5 | 64.4 | 76.4 | 62.6 |
68 | 80 | AA,A | 6/1 | 27.6 | 26.7 | 26.4 | 29.8 | 24.6 |
69 | 71 | AA(HS) | 12/7 | 62.9 | 60.2 | 57.4 | 68.1 | 55.8 |
70 | 63 | AA(HS) | 12/7 | 56.2 | 53.8 | 51.3 | 60.8 | 49.9 |
71 | 63 | AA,A | 6/1 | 22.1 | 21.4 | 21.1 | 23.8 | 20.4 |
72 | 56 | AA(HS) | 12/7 | 50.2 | 48 | 45.8 | 54.3 | 44.5 |
73 | 50 | AA(HS) | 12/7 | 45.4 | 43.5 | 41.5 | 48.2 | 41.5 |
74 | 50 | AA,A | 6/1 | 18.1 | 17.5 | 17 | 19.2 | 16.4 |
75 | 40 | AA(HS) | 8/1 | 22.5 | 21.5 | 21.1 | 24.7 | 19.3 |
76 | 40 | AA,A | 6/1 | 14.9 | 14.4 | 14 | 15.7 | 13.7 |
77 | 31.5 | AA,A | 7/1 | 15.1 | 14.6 | 14 | 16.2 | 13.5 |
78 | 31.5 | AA,A | 6/1 | 11.9 | 11.6 | 11.2 | 12.6 | 11 |
79 | 25 | AA,A | 7/1 | 12.3 | 11.9 | 11.5 | 131 | 11.2 |
80 | 25 | AA,A | 6/1 | 9.65 | 9.37 | 9.09 | 10.1 | 9.09 |
81 | 20 | AA,A | 7/1 | 10 | 9.69 | 9.34 | 10.7 | 9.15 |
82 | 20 | AA,A | 6/1 | 7.84 | 7.62 | 7.39 | 8.29 | 7.39 |
83 | 16 | AA,A | 6/1 | 6.33 | 6.15 | 5.97 | 6.69 | 5.97 |
84 | 12.5 | AA,A | 6/1 | 4.97 | 4.83 | 4.69 | 5.25 | 4.69 |
Main features
Type: Bare
Conductor Type: Stranded
Application: Overhead Transmission Line
Conductor Material: Aluminum
Sheath Material: Bare
Insulation Material: Bare
Basic Information
Model No: ACSR Conductor
Material Shape: Round Wire
Range of Application: Overhead Installation
Certificate: ISO9001,ISO14001, CCC, CE
Brand Name: GDYG
ACSR Code: Turkey, Swan, etc
ACSR Feature: Simple Construction, Easy Installation, Excellent Electric and Mechanical and Conductive etc
Specification: 10mm2 – 1500mm2
ACSR Conductor Advantage: Antiseptic Model.
Supply Record: African countries, Arabian countries, Asian countries etc.
Origin: Guangdong, China
HS Code: 7614100000
Our Company
Workshop
Test
Certificates
Customers
We are China IEC/ASTM/BS/DIN Standard ACSR Conductor, Aluminium Conductor Steel Reinforced, Overhead Bare Aluminium Transmission Line. manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ACSR Cable Products
IEC Standard Aluminum Conductor Steel Reinforced ACSR Overhead Line Cable
Low Voltage Single Core XLPE Insulated ACSR Cable
ACSR "Wolf" Conductor Bare Power Cable.
Aluminum Electrical Conductor AAC, ABC, AAAC, ACSR Cable
Aluminum Conductor ACSR Conductor Linnet ASTM B232, Overhead Conductor
Aluminum Stranded Conductor Steel Reinforced, ACSR Conductor. Steel Cored for Aluminum
Popular ACSR Conductor Products
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Bunting
ACSR Conductor Horse with BS Standard
ACSR Drake Bare Conductor/ACSR Eagle Overhead Conduct/Bare ACSR Conductors, Electric Wire
Aluminium Cables Free Samples 795 Mcm ACSR Conductor
Popular Overhead ACSR Products
ASTM B232 ACSR 636 Mcm ACSR Conductor Price List Bare Conductor Sizes
Aluminium Conductor Steel Reinforced ACSR Conductor, Electric Bare Cable.
Overhead Bare Aluminum Cable Wire ACSR Conductor
ACSR Power Transmission Line, Bare Aluminium Cable, Aluminium Conductor Steel Reinforced.
ASTM B232 Overhead Conductor Steel Reinforced ACSR
Popular vangocable Products
0.6/1kv Electric Cables XLPE Insulated PVC Sheathed
CCC Standard Copper Conductor Cable XLPE Insulated Building Electrical Wire Power Cable
High Voltage Power Copper XLPE Insulated
PVC Insulated Electric Cable Steel Wire Armored Power Cable
300/500V and 450/750V PVC Copper Flexible 4 Cores 1sqmm Control Cable
Tags: ACSR Cable, ACSR Conductor, Overhead ACSR, vangocable