Model NO.
JSZJK

Operation Condition
Outdoor

Usage
Protection

Winding Form
Single Layer & Tightly Wound Type

Insulating Medium
Insulating Paper

Installation
Extension Type

Magnetic Circuit Structure
Combined Type

Voltage Transformation Principle
Photoelectric Type

Defense
Secure

Transport Package
Material Flow

Specification
10KV 5-1000A

Trademark
CNKC

Origin
China

Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
70.00cm * 21.00cm * 31.00cm

Package Gross Weight
60.000kg

Product Description

Product Description

JSZJK-10Q voltage transformer is a three-phase, indoor and dry type product, JSZK1-10 is Yo/Yo[connection JSZK1-10F is Yo/YoIYO[connection. The anti-resonance part is a single body. It is suitable for electric energy metering, voltage monitoring and relay protection in the rated frequency of 50Hz or 60HZ. The rated voltage is 6kV.

Model Description

Technical parameters and structure dimensions

Rated insulation 11.5/42/75KV
Rated frequency 50HZ
Ambient temperature -5ºC – +40ºC
The power factor of the load COSΦ=0.8 (lag);
Altitude is less than or equal to 1000m, which meets Class II pollution level;
Product performance meets the standard: GB1207-1997 (voltage transformer)

Product features and scope of use

1. JSZJK-10Q voltage transformer is an indoor epoxy resin full vacuum casting structure. Its surface creepage distance is greater than 25.m/kV
2. When the JSZK1-10 and JSZK1-10F voltage transformers are used in the system, each of them has four casting bodies, and the inner part is three voltage casting bodies, which are sleeved on the three-phase core column, and the anti-resonance part is installed in another port. On the iron core, during normal operation, the neutral point-to-ground voltage is zero volts, and the secondary output voltage of the anti-resonance part is zero volts, and one is short -circuited to ground. The secondary side (da-dn) of the anti-resonance part generates a voltage of 100V, which drives the relay to act, and the neutral point of the power supply is cut off. Harmonic elimination measures are adopted, so that the product does not need additional protection methods such as harmonic elimination or damping grounding, that is, it can be safely It can operate on the power grid and can operate in a single-phase grounded fault line for a long time.
environmental conditions:
1. The altitude does not exceed 1000m;
2. The ambient temperature is not higher than +40c, not lower than -5 ºC;
3. The relative humidity of the surrounding air is not more than 85% (20c);
4. There is no corrosive gas in the installation site

Ordering instructions and usage matters

Order plan:
1. Provide wiring scheme diagram number, purpose and single-line system diagram, rated voltage, rated current, etc.
2. Requirements for switchgear control, measurement and protection functions and other locking and automatic devices
3. When the switchgear is used in special environmental conditions, it should be explained in detail when ordering
4. When other or more accessories and spare parts are needed, the type and quantity should be proposed
Precautions:
1. Before the voltage transformer is put into operation, the test and inspection shall be carried out according to the items specified in the regulations. For example, measuring polarity, connection group, shaking insulation, nuclear phase sequence, etc.
2. The wiring of the voltage transformer should ensure its correctness. The primary winding should be connected in parallel with the circuit under test, and the secondary winding should be connected in parallel with the voltage coil of the connected measuring instrument, relay protection device or automatic device. At the same time, attention should be paid to the correctness of the polarity. .
3. The capacity of the load connected to the secondary side of the voltage transformer should be appropriate, and the load connected to the secondary side of the voltage transformer should not exceed its rated capacity, otherwise, the error of the transformer will increase, and it is difficult to achieve the correctness of the measurement.
4. No short circuit is allowed on the secondary side of the voltage transformer. Since the internal impedance of the voltage transformer is very small, if the secondary circuit is short-circuited, a large current will appear, which will damage the secondary equipment and even endanger personal safety. The voltage transformer can be equipped with a fuse on the secondary side to protect itself from being damaged by a short circuit on the secondary side. If possible, a fuse should also be installed on the primary side to protect the high -voltage power grid from endangering the safety of the primary system due to the failure of the high-voltage winding or lead of the transformer.
5. In order to ensure the safety of people when touching measuring instruments and relays, the secondary winding of the voltage transformer must be grounded at one point. Because after grounding, when the insulation between the primary and secondary windings is damaged, it can prevent the high voltage of the instrument and the relay from endangering personal safety.
6. Short circuit is absolutely not allowed on the secondary side of the voltage transformer

Product details

Products real shot

A corner of the production workshop

Product packaging

Product application case

 

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnkcele Products

Sg 100-3600kVA 380-3300V Three-Phase Tunnel Special Booster Dry-Type Transformer

S (F) Z Series 10-35kv 100-31500kVA Three Phase on Load Voltage Regulating Oil Immersed Power Transformer

SBW 25-300mm² Electric Power Equipment Clamp Transformer&Disconnector Aluminum Alloy Torque Locking Connection Device

Fxgb 10-220kv Overhead Line Anti-Dancing Insulator Composite Interphase Spacer

Ksg 6-10kv 50-1600kVA 400-1200V Common Type Mine Dry-Type Transformer Hermetic Transformer

Dl 16-800mm² 8.4-21mm Aluminium Connecting Terminal Cable Lug Electric Power Fitting

Popular Jszjk-10q 3000√ 3/100√ 3 /100V 60-100va Indoor Dry Type Anti-Resonance Three-Phase Voltage Transformer Products

  • No related articles
  • Popular Outdoor Oil Immersed High Voltage Transformer Products

    Jdjj2 35kv 35000/√ 3V 0.5/6p Outdoor High Voltage Oil Immersed Voltage Transformer

    Jlszy3-20 20000/100V 5-200/5A Outdoor Dry Type High Voltage Power Combined Transformer

    Jdzw-10r 10kv 30va Outdoor Voltage Transformer Zw32 Vacuum Circuit Breaker Special Power Supply PT High Voltage Transformer

    Jlszv-10W 6/10kv Outdoor Dry Three-Phase High Voltage Metering Box Combined Transformer

    Jdz (J) 3kv 6kv 10kv PT Cabinet Single-Phase Indoor Medium

    Jls-35kv/100V 5-300A 30/50va 10/20va Outdoor Oil-Immersed Combination Transformer High Voltage Power Metering Box

    Popular Single-Phase Oil-Immersed Transformer Products

    La-10 5-40A 0.2-0.5/10p 10/15va Indoor Semi-Enclosed Through-Wall High Voltage Current Transformer

    Jlszw 10kv 5-1000A 10-80ka Outdoor Stainless Steel Combined Transformer Dry Inverted Power Metering Box

    Jls 3/6/10kv 5A Outdoor Oil-Immersed High-Voltage Power Metering Box Three-Phase Three-Wire Combined Transformer

    Jlszv-10W 6/10kv Outdoor Dry Three-Phase High Voltage Metering Box Combined Transformer

    S (F) S (Z) Series 220/330/500kv 31500-300000kVA Intelligent Three-Phase Ultra-High Voltage Oil Immersed on Load Voltage Regulating Power Transformer

    Jlszy-10kv 5-1000A 10va Outdoor Three-Phase Four-Wire Combined Transformer High Voltage Power Metering Box

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION