Jszw3-10 10000/√ 3/100/√ 3/100/3V 1000va Indoor Three-Phase Dry-Type High Voltage Voltage Transformer
Jszw3-10 10000/√ 3/100/√ 3/100/3V 1000va Indoor Three-Phase Dry-Type High Voltage Voltage Transformer image
Get Latest Price Request a quote
Basic Info.
Packaging & Delivery
Product Description
Product Description
JSZW3-3, 6, 10 voltage transformers are indoor epoxy resin casting semi-closed structure, suitable for voltage, electric energy measurement and relay protection in AC 50HZ voltage 3, 6, 10KV neutral point non-effective grounding power system According to different installation methods, the product is divided into A type and B type.
Model Description
Technical parameters and structure dimensions
Product features and scope of use
This type of voltage transformer is a semi-casting type, with small size and strong climate adaptability. The core of the transformer adopts a core-type structure with a side iron yoke, and is made of high-quality cold-rolled silicon steel sheets stacked in a rectangle. The primary, secondary and residual voltage windings are concentrically wound together, cast and molded with epoxy resin, and the three-phase casting body is fixed together. The primary winding is fully insulated at the A end, and the other N end is not fully insulated. The wiring diagram is shown in Figure 1: According to the installation method, this product is divided into A type and B type. Type A products are installed on the side, and the mounting holes are on the iron core clip. Type B products have a mounting base, which is used to strengthen the product.
Conditions of Use:
1. The altitude does not exceed 3000 meters;
2. The ambient temperature is not higher than ten 40’C, not lower than one 5’C;
3. The relative humidity of the air in the weekly warehouse is not more than 85% (20 C);
4. There is no corrosive gas in the installation site
Precautions for product use
1. Before the voltage transformer is put into operation, the test and inspection shall be carried out according to the items specified in the regulations. For example, measuring polarity, connection group, shaking insulation, nuclear phase sequence, etc.
2. The wiring of the voltage transformer should ensure its correctness. The primary winding should be connected in parallel with the circuit under test, and the secondary winding should be connected in parallel with the voltage coil of the connected measuring instrument, relay protection device or automatic device. At the same time, attention should be paid to the correctness of the polarity. .
3. The capacity of the load connected to the secondary side of the voltage transformer should be appropriate, and the load connected to the secondary side of the voltage transformer should not exceed its rated capacity, otherwise, the error of the transformer will increase, and it is difficult to achieve the correctness of the measurement.
4. No short circuit is allowed on the secondary side of the voltage transformer. Since the internal impedance of the voltage transformer is very small, if the secondary circuit is short-circuited, a large current will appear, which will damage the secondary equipment and even endanger personal safety. The voltage transformer can be equipped with a fuse on the secondary side to protect itself from being damaged by a short circuit on the secondary side. If possible, fuses should also be installed on the primary side to protect the high-voltage power grid from endangering the safety of the primary system due to the failure of the transformer’s high-voltage windings or lead wires.
5. In order to ensure the safety of people when touching measuring instruments and relays, the secondary winding of the voltage transformer must be grounded at one point. Because after grounding, when the insulation between the primary and secondary windings is damaged, it can prevent the high voltage of the instrument and the relay from endangering personal safety.
6. Short circuit is not allowed on the secondary side of the voltage transformer.
Products real shot
A corner of the production workshop
Product packaging
Product application case
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Jszw3-10 10000/√ 3/100/√ 3/100/3V 1000va Indoor Three-Phase Dry-Type High Voltage Voltage Transformer manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular cnkcele Products
Fnb4 1-35kv Composite Tensile Insulator for High Voltage Transmission Lines
Byd 35-240mm² 1-10kv Overhead Insulated Power Line Electric-Check Grounding Ring Device
Popular Jszw3-10 10000/√ 3/100/√ 3/100/3V 1000va Indoor Three-Phase Dry-Type High Voltage Voltage Transformer Products
Popular Outdoor Oil Immersed High Voltage Transformer Products
Jlszy3-20 20000/100V 5-200/5A Outdoor Dry Type High Voltage Power Combined Transformer
Jdj2 35kv 35000/100V 0.2/6p 80-500va Outdoor Hv Oil-Immersed Insulation Voltage Transformer
Jdjj2 35kv 35000/√ 3V 0.5/6p Outdoor High Voltage Oil Immersed Voltage Transformer
Lzzbj4-35kv 200-500A 1600A Indoor Dry Type Pillar Type High Voltage Current Transformer
Jdz9 27.5/35kv 60/250/ 500va Dry-Type Voltage Transformer for Measurement in Hv Cabinets
Popular Single-Phase Oil-Immersed Transformer Products
Lzzbj4-35kv 200-500A 1600A Indoor Dry Type Pillar Type High Voltage Current Transformer
Jdjj2 35kv 35000/√ 3V 0.5/6p Outdoor High Voltage Oil Immersed Voltage Transformer
Lxk-80/100/120 Aperture 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening
Tags: cnkcele, Jszw3-10 10000/√ 3/100/√ 3/100/3V 1000va Indoor Three-Phase Dry-Type High Voltage Voltage Transformer, Outdoor Oil Immersed High Voltage Transformer, Single-Phase Oil-Immersed Transformer