K Type T Type IEC High Voltage 33kv Dropout Fuse Link

China 
                        K Type T Type IEC High Voltage 33kv Dropout Fuse Link
                      manufacture and supplier

K Type T Type IEC High Voltage 33kv Dropout Fuse Link image

Get Latest Price Request a quote

Quick Details

K Type T Type IEC High Voltage 33kv Dropout Fuse Link

IEC IEEE

Fuse Link

T K

Circle

High Voltage

Distribution

High

533,660,787

Removeable ,Fixed

OEI Power

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

85389000

Product Details

"K" and "T" type fuse link, according to IEC-282 standard. They are suitable for drop out fuse cut out with rated voltage

HIGH VOLTAGE EXPULSION TYPE FUSE LINKS
 

TABLE OF CONTENTS
 
ITEM                                                                                                                         

TITLE                                                                             PAGE
 
PART 1 GENERAL
 
1.01   SCOPE                                                               E13 1
 
1.02   STANDARDS                                                E13 1
 
1.03   SERVICE CONDITIONS                                E13 2
 
1.04  SYSTEM CONDITIONS                                     E13 2
 
1.05  TESTING                                                             E13 2
 
1.06  SPARES                                                             E13 3
 
1.07   PACKING AND SHIPMENT                             E13 3
 
1.08  SUBMITTALS                                                     E13 3
 
PART 2 PRODUCTS
 
2.01 DESIGN                                                                E13 4
 
A.  Standardization of Fuse Links                               E13 4
B.  Rating of Fuse Links                                               E13 4
C.  Characteristics of Fuse Links                                E13 4
 
2.02  MATERIALS                                                        E13 4
 
A.  Current Carrying Parts of Fuse Links                   E13 4
B.  Fuse Link Button                                                     E13 5
C.   Length of Fuse Links                                              E13 5
D.   Pull on Fuse Links                                                  E13 5
E.   Identification                                                            E13 5
 
TECHNICAL DATA SCHEDULE                                E13 6

PART 1          GENERAL
 

 
1.01      SCOPE
 
This Specification covers the design, manufacturing, testing, supply, delivery and performance requirements of HV Expulsion Type Fuse Links for use by the Electricity Company of Ghana Limited.
 
1.02    STANDARDS
 
The fuse links shall comply with the latest editions of and amendments to, the standards/specifications listed below:
 
IEC                                                  – International Electrotechnical Commission
 
IEC 60282                                –     High Voltage Fuses Part 2: Expulsion and similar fuses
 
ANSI                                                American National Standards Institute
 
IEEE C37.41                            –     Design for High Voltage Fuses, Distribution Enclosed Single Pole Air Switches.  Fuse Disconnecting Switches and Accessories.
 
ANSI C37.42                            –     American National Standard Specifications for Distribution Cutouts and Fuse Links.
 
NEMA                                               National Electrical Manufacturers Association
 
NEMA SG2                              –     High Voltage Fuses

 

 
 
1.03    SERVICE CONDITIONS
 
As in Specification H0C
 
 
1.04    SYSTEM CONDITIONS
 
As in Specification H0C
 
 
1.05    TESTING
 
Type Tests
 
A.       The Supplier shall confirm on the attached schedule that the following tests have been performed according to ANSI C37.42.
 
1.        Melting Current Tests; Table 6
 
2.        Temperature Rise Tests
 
3.        Time/Current Characteristic Tests
 
B.       Type/Design Tests may (at the Purchaser’s discretion) be dispensed with if the Supplier/Contractor furnishes evidence to the Purchaser’s satisfaction that the relevant tests have already been performed on identical equipment.  In this case the Supplier shall provide documentary proof in the form of Certified Test Certificates that the assembled equipment and its component parts been successfully typetested by an independent testing authority in accordance with the relevant clauses of referenced Standards.  Test Certificates as evidence of successful completion of type tests shall be submitted as part of the Bid.
 
C.       Inspection
 

 

The Purchaser reserves the right to witness the manufacturing process, any type tests specifically performed on the materials to be supplied to Customer  and any routine tests required in the manufacture and supply of such equipment.  The Supplier shall provide free access to the Purchaser to any site where such manufacturing process, or  tests, either type or routine tests are taking place.  The Supplier shall bear the in plant costs of such witness.  The Supplier shall provide the Purchaser of a schedule of manufacture and tests at least two weeks before the events are to occur.
 
 
1.06    SPARES
 
(NOT APPLICABLE)
 
 
1.07    PACKING AND SHIPMENT
 
As in Specification H0C
     
 
1.08    SUBMITTALS
 
As in Specification H0C

 

PART 2          PRODUCTS
 
2.01    DESIGN
 
A.       Standardization of Fuse Links (Mechanical/Interchangeable).
 
High voltage expulsion fuses shall be suitable for use on the Expulsion fusegears described in the associated specifications H16 and H34.
 
B.       Rating of Fuse Links
 
The preferred rating of fuse links shall be 3A, 5A, 8A, 16A, 25A, 40A, 63A and 100A at 11kV and 1A, 2A, 3A, 5A, 8A, 16A, 20A and 31.5A at 33kV.  The rated current of the fuse link is the maximum current which it will carry continuously without deterioration and undue heating.  Supplier shall state on the attached schedule the maximum temperature in oC attained by the fuse link after continuous operation at maximum rating.
 
C.       Performance Characteristics of Fuse Links
 
1.        The fuse links are required to give protection against short circuits.  They shall be so rated and shall have such blowing characteristics as to be suitable for selective operations with the fuse links at present in use on the system namely Type K i.e. fast, fuse links to NEMA SG2 and ANSI C37.42 1981.
 
2.        The Supplier shall present to the Purchaser timecurrent characteristics of all the distribution fuselinks on offer.  The performance characteristics of the fuselinks shall include:
 
(a)       Meltingtimecurrent characteristics
(b)       Total clearingtimecurrent
 
The timecurrent characteristics shall be presented as curves.
 
The Supplier shall state the minimum and maximum melting currents required to melt the fuse links at the three appropriate time points used in Table 6 {meltingcurrents for TypeK (fast) fuse links) of ANSI C37.42 1981
 
 
2.02      MATERIALS
 
A.       Current carrying Parts of Fuse Links
 
All current carrying parts of the fuse links shall be nonferrous material; the main requirements being resistance to atmospheric corrosion.  Tin is not acceptable as a possible element.
 

Supplier shall state composition of:
 
1.        Fuse Element
 
2.        Fuse Link
 
B.       Fuse Link Button
 
The diameter of the button head cap on fuse links shall be 19.1mm.  Removable type button heads are preferred for use with 11kV fusegear.
 
C.       Length of Fuse Links
 
The minimum overall length of fuse links rated 1 to 100 amperes shall be:
 
:          510mm for 11kV units per ANSI C.37.42
 
:          762mm for 33kV units per ANSI C.37.42
 
D.       Pull on Fuse Links (Tensile Withstand Strength)
 
The expulsion fusegear shall operate satisfactorily while exerting a pull of 44.5N on the fuse link per ANSI C.37.42, 3.2.3.4 1981.
 
E.        Identification
 
Each fuse link must have stamped on it:
 
1.        Manufacturers name or identifying mark
 
2.        Continuous current rating
 
3.        Type designation, K or T

We are China K Type T Type IEC High Voltage 33kv Dropout Fuse Link manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Fuse Products

11kv, 24kv, 33kv, 36kv Dropout Fuse Cutout with Composite Insulator

24kv High Voltage Fuse Cutout

Fuse Base, Fuse Link, Fuse

Outdoor Expulsion Drop-out Polymer Distribution Fuse Cutout

15kv/27kv/33kv/36kv 100A/200A/300A Outdoor Cut out (Drop out) Fuse

High Voltage Dropout Fuse (Vc-13) Fuse Cutout, Porcelain Cutout Fuse Cutout, Silicon Cutout

Popular Fuse Cutout Products

38kv Ceramic High Quality Drop out Fuse Cutout

T-Connectors for Tubular Bus-Bar Type Mgt/C

11kv Composite Cutout Fuse Polymer Dropout Fuse Silicon Fuse Cutout Gang Insulator Isolating Switch 15kv 22kv 33kv Porcelain Ceramic

12kv Polymer Housed Cutout Fuse Cfs-8r-12-350

Fuse Cutout, Drop out Fuses 27kv 100A

Lightning Electricity Testing Earthing Ring (Piercing / Non-piercing)

Popular jgtrade1 Products

33kv 630A Load Isolators High Voltage

Pg Clamp

Clevis, Ball End, Y, Cat

Polymeric Expulsion Fuses 21kv 200A

Brace, Flatwood Crossarm 32"

Composite Insulator 70kn - BS16 - 36kv Leakage Line 610mm Number of Sheds 7

Popular Transformer Fuse Products

Surge Arrester Substation Line Arrester Transmission 66kv

"K" and "T" Type Fuse Link

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION