Language Signboard
Language Signboard image
Get Latest Price Request a quote
Quick Details
Product Details
The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
CSA CANADIAN STANDARDS ASSOCIATION
G164-4 – Hot dip galvanizing of Irregular Shaped Articles
CAN/CSA – Quality Assurance Program Categories 2299.3
ANSI – AMERICAN NATIONAL STANDARDS INSTITUTE
C29.1 – American Standard Test Method For Electrical Power Insulators
C29.7 – American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
987-1985 – IEEE Guide For Application of Composite Insulators
D750 – Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
D1499 – Recommended Practice For Exposure of Plastics.
D2240 – Rubber Properties, Durometer Hardness
D2565 – Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core
The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
i. are compressed onto the Fibreglass rod member
ii. are not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii. are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
The insulator are provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load.
Performance Characteristics
The Polymeric Insulators are meet the under listed performance characteristics.
| ITEM |
11kV |
33KV |
| Dry Flashover Withstand |
90kV |
180kV |
| Wet flashover withstand |
70kV |
165kV |
| Positive Impulse Critical flashover |
145kV |
300kV |
| Maximum Radio Interference Voltage |
Below 1micro volt |
Below 1 micro volt |
| Design Tension Strength |
100kN |
100kN |
| Residual Strength after Power Arc |
80kN |
80kN |
| Mechanical Proof Test Load |
45kN |
45kN |
| Maximum Sustained Load |
34kN |
34kN |
| Design Torque Rating |
83 Nm |
83 Nm |
The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.
Recommended for You
Not exactly what you want?
Post Sourcing Request
Hot Searches
Voltage Insulator
Silicone Rubber Wire
High Voltage Insulator
Rubber Insulator
Ceramic Insulator
We are China Language Signboard manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Composite Insulator Products
15-70 Kn Polymer Composite Suspension Insulator for Transmission
120kn Polymer Housing ISO Manufacturer, High Tension Long Rod Insulator
15kv Overhead Transmission Line Post Composite Insulator
High Voltage Fxbw-24/70 Polymer Composite Suspension Insulator (24kv)
130kv Composite Station Post Insulators
Popular jgtrade1 Products
Outdoor Single Pole Fused Recloser by-Pass Switches24kv 600A
15kv 100A-200A Electrical Porcelain Drop-out Fuse Cutout
Lightning Arrester, Polymer Metal Oxide Surge Arrester 3-132kv, 10ka
415VAC 500VAC Slotted Wedge HRC High Breaking Capacity Jpu Fuse Link
Fuse Cutout, Drop out Fuses 12kv 300A
Popular Polymer Insulator Products
ANSI Standard Solid Core Station Post Insulators for Power Station
Dimension Test for Strain Cable Tie 3.6X300mm:
230kv High Voltage Insulator Polymer Station Post Insulator
24kv Composite Silicone Rubber Suspension Electrical Insulator
Electric High Voltage Composite Insulator
Popular Silicone Rubber Insulator Products
15kv 70kn Composite Suspension Insulator, Polymer Housing Insulator Manufacturer
with-Button Wire. New with-Trip Fuse Wire, High-Voltage Condenser's Pecial Fuse Wire
Isoladores De Porcelana Polymer Insulator
Polymer Insulator 11kv Tension 120kn
Tags: Composite Insulator, jgtrade1, Polymer Insulator, Silicone Rubber Insulator