Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters
Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type: |
Y5W5-108/259 |
||
Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
Line discharge level | 2 | Creepage distance —-mm | 3906 |
2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Station Class 3 Moa Zinc Oxide Surge Arrester/Lightning Arrestor
Wholesale Cheap Polymeric Surge Protector Arrestors in 132kv Transmission Line
Zinc Oxide Varistor Disc for Lightning Surge Arresters
Substation Type of Lightning Arresters Rated Voltage 21kv/Line Discharge Class1
Lighting Arrestor Surge Arrester Lightning Protector Surge Protector
230kv Power Distribution System Silicone ZnO Lightning Protector 100kv
Popular Lightning Arrester Products
High Quality Building Lightning Arrester
24kv Polymeric ZnO Lightning Arrester/Surge Arrester for Transmission and Distribution Line
12kv Metal Oxide Lightning Arrester for Overvoltage Protection
Stainless Steel Fence (square pipe / round pipe)
Popular Surge Arrester Products
Aiso Electrie Provide Better Price Polymer Surge Arrester
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Brown Surge Protection Device Arrester
Al-Cu Transition Connectors Type Syg, Compression Type, Group a
Metal Oxide Silicon Rubber Lighting Metal Oxide Arrester
Yh10W-108, 108kv 10ka Surge Arrester
Popular Surge Arresters Products
Polymeric Housed Zinc Oxide Surge Arresters Without Gaps
Mv Composite Metal Oxide Surge Arrester Without Gaps
Line 2ms Current 600A Porcelain Composite Polymer Surge Absorber
200kv Metal Oxide Surge Diverters for Electric Station
Surge Arrester 30kv 33kv 36kv Metal-Oxide Composite Lightning Surge Arrester
5ka 3-36kv Polymeric Housed Zinc Oxide Lightning Arresters Without Gaps
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters