Liyond 3.6kv Low Voltage 400A 630A Vacuum Contactor
Liyond 3.6kv Low Voltage 400A 630A Vacuum Contactor image
Get Latest Price Request a quote
Basic Info.
Packaging & Delivery
Product Description
Liyond 3.6kV Low voltage 400A 630A vacuum contactor
General description
JCZ3-3.6KV vacuum contactor JCZ3-3.6 type indoor high-voltage AC vacuum contactor is a three-phase AC 50Hz indoor high-voltage electrical equipment, suitable for rated 3.6kV and below voltage level, can realize the control of various forms of current circuits such as three-phase motors, transformers, capacitors and pure resistance loads and other electrical equipment, and for high-voltage electrical equipment that are not subject to atmospheric overvoltage. High-frequency switching and continuous operation of equipment not subject to atmospheric overvoltage.
Technical parameters
| Model | JCZ3-3.6 |
| Rated operating voltage | 3.6kV |
| Rated working current | 400A 630A |
| Rated frequency | 50Hz |
| Rated closing capacity | 10Ie (AC-4) |
| Rated breaking capacity | 8Ie (AC-4) |
| Rated short-time withstand current | 10Ie |
| Rated peak withstand current | 25Ie |
| Rated short circuit withstand time | 4s |
| Power frequency withstand voltage phase to phase | 2kV |
| Power frequency withstand voltage to ground | 25kV |
| Lightning impulse withstand voltage | 40kV |
| Rated voltage | AC/DC 110/220V |
| Electrical maintenance | ≤600/50(Closing/holding) |
| Power frequency withstand voltage of control circut and auxiliary circuit to ground | 2 |
| Rated operating frequency long term | 300 |
| Rated operating frequency short term | 600 |
| Mechanical life | 30 |
| Electrical life | 10 |
| Closing time | ≤200 |
| Inherent opening time | ≤160 |
| 3 phases Not simultaneous | ≤3 |
| Switching bounce | ≤10 |
Normal use conditions
a) Upper limit of ambient air temperature: +40°C, lower limit: -25°C
b) The altitude does not exceed 2000M
c) Humidity: The daily average value of relative humidity is not more than 95%, the monthly average value is not more than 90%: the daily average value of water vapor pressure is not more than 2.2KPA, and the monthly average value is not more than 1.8KPA
d) The surrounding air should not be significantly polluted by corrosive or flammable gas and water vapor
e) Infrequent strenuous exercise
f) When the contactor moves, the inclination angle between the installation plane and the horizontal is not more than 5°
g) Requirements beyond the above conditions shall be agreed by the user and the manufacturer.
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Liyond 3.6kv Low Voltage 400A 630A Vacuum Contactor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Jcz3 Vacuum Contactor Products
Popular liyond Products
12kv Fn7 High Voltage Air Load Break Switch for Switchgear
Liyond Manufacturer 12kv Medium Voltage Kyn28 Metal Clad Withdrawable Switchgear
Vs1 High Voltage Switchgear Contacts Sulfidizing Arm 3150A
Factory Price 24kv Medium Voltage Vacuum Switches Indoor Sf6 Load Break Switch Housing
Vcb Steel Guide Rail Mechanism Device for High Voltage Switchgear
Closed Position Load Break Disconnect Switch
Popular Liyond 3.6kv Low Voltage 400A 630A Vacuum Contactor Products
Popular Vacuum Contactor Products
5 Poles Voltage Contactor Vacuum Swith for Substation
Low Voltage Ckj20 Series Vacuum Switch for Capacitor Bank
High Voltage 3 Poles Vacuum Contactor Vacuum Switchg for Power Substation
12kv Mv Contactor Ckg3 Vacuum Contactor with Small Current 160A
Big Current Jcz5 Vacuum Contactor for Capacitor Bank
7.2kv Jcz5 Vacuum Interrupter Contactor
Tags: Jcz3 Vacuum Contactor, liyond, Liyond 3.6kv Low Voltage 400A 630A Vacuum Contactor, Vacuum Contactor