Low-Toxicity Flame Retardant Shipboard Flexible Power Cable Hfix Cable

China 
                        Low-Toxicity Flame Retardant Shipboard Flexible Power Cable Hfix Cable
                      manufacture and supplier

Low-Toxicity Flame Retardant Shipboard Flexible Power Cable Hfix Cable image

Get Latest Price Request a quote

Quick Details

Low-Toxicity Flame Retardant Shipboard Flexible Power Cable Hfix Cable

Control Cable

Low, Medium, High Voltage

ZRYJV22

ISO, CCC

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low, Medium, High Voltage

Construction, Overhead, Underground, Industrial, Power Station

1, 2, 3, 4, 5, 3+1, 4+1, 3+2

GB/T 12706-2008, IEC 60502-2005

Black or as Request

Copper Tape, Copper Wire

Galvanized Steel Wire, Steel Tape, Copper Tape

50mm, 95mm, 120mm, 150mm

0.6/1kv, 8.7/15kv, 12/20kv, 21-35kv, 36kv

Yes

Factory

KINGYEAR

Steel-Wooden Drum or as Request

0.5-800mm2

Henan, China

8544492100

Product Details

low-toxicity flame retardant shipboard flexible power cable HFIX cable

Standard:

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

The Rated Voltage(kv):

1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35

Application:

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

1.5mm2 pvc control cable copper wire braid shield flexible control cable

Applications
Control cables are suitable for connection in control, signal, protection circuit and measuring system with rated power-frequency voltage 450/750V or 0.6/1KV.

Characteristics
1.The maximum permissible continuous operating temperature is 70ºC
2.The lowest installation temperature of the cable is 0ºC.
3.Permissible Min. Bending radius: not less than 6 times of the completed cable diameter for unarmored cable; not less than 12 times of the completed cable diameter for armoured or copper tape screened cable; not less than 6 times of the completed cable diameter for screened flexible cable.

Standard
 The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

Specification 

Type Name Section Area(mm2) No. of Core Application Site
KVV Copper Conductor,PVC Insulated and Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KVVP Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KVVP2 Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KVV22 Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force
4 6 4-14
10 4-14
KVVR Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KVVRP Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable 0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5 2.5 4-48
KYJV Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KYJV22 Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force
4 6 4-14
10 4-10
KYJVP2 Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable 0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches or pipes where shielding is required
4 6 4-14
10 4-10
KYJVR Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable 0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KYJVRP Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable 0.5 0.75 1.0 4-61  
    1.5 2.5 4-48 Installation indoors where flexibility shielding and movability are required

Production process

Package
Package by roll or in Export Wooden or Steel Wooden or Steel Drums

Testing

Contact us
—————————————————–
 
 
 
 

—————————————————–

 

   
   
       
       
       
       

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Specification

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1×4 2.3 0.7 1 0.8 1.8 10.9
1×6 2.8 0.7 1 0.8 1.8 11.4
1×10 3.6 0.7 1 0.8 1.8 12.2
1×16 4.5 0.7 1 0.8 1.8 13.1
1×25 5.6 0.9 1 0.8 1.8 14.6
1×35 6.7 0.9 1 1.25 1.8 16.6
1×50 8 1 1 1.25 1.8 18.1
1×70 9.4 1.1 1 1.25 1.8 19.7
1×95 11 1.1 1 1.6 1.8 22
1×120 12.4 1.2 1 1.6 1.8 23.6
1×150 13.8 1.4 1 1.6 1.8 25.4
1×185 15.3 1.6 1 1.6 1.8 27.4
1×240 17.5 1.7 1 1.6 1.9 29.9
1×300 19.5 1.8 1 2 2 33.1
1×400 22.6 2 1.2 2 2.2 37.3
1×500 25.2 2.2 1.2 2 2.3 40.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2×1.5 1.4 0.7 1 0.8 1.8 12.8
2×2.5 1.8 0.7 1 0.8 1.8 13.6
2×4 2.3 0.7 1 0.8 1.8 14.6
2×6 2.8 0.7 1 1.25 1.8 16.5
2×10 3.6 0.7 1 1.25 1.8 18.1
2×16 4.5 0.7 1 1.25 1.8 19.9
2×25 5.6 0.9 1 1.6 1.8 23.6
2×35 6.7 0.9 1 1.6 1.8 25.8
2×50 8 1 1 1.6 1.9 29
2×70 9.4 1.1 1 2 2 .3 3.2
2×95 11 1.1 1.2 2.1 3 7.1
2×120 12.4 1.2 1.2 2 2.3 40.5
2×150 13.8 1.4 1.2 2.5 2.4 45.4
2×185 15.3 1.6 1.4 2.5 20.6 49.9
2×240 17.5 1.7 1.4 2.5 20.7 55.1
2×300 19.5 1.8 1.6 2.5 20.9 60.2
2×400 22.6 2 1.6 2.5 30.1 67.7

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3×1.5 1.4 0.7 1 0.8 1.8 13.2
3×2.5 1.8 0.7 1 0.8 1.8 14.1
3×4 2.3 0.7 1 0.8 1.8 15.2
3×6 2.8 0.7 1 1.25 1.8 17.1
3×10 3.6 0.7 1 1.25 1.8 18.9
3×16 4.5 0.7 1 1.25 1.8 20.8
3×25 5.6 0.9 1 1.6 1.8 24.7
3×35 6.7 0.9 1 1.6 1.8 27.2
3×50 8 1 1 1.6 1.9 30.6
3×70 9.4 1.1 1 2 2.1 35.2
3×95 11 1.1 1.2 2 2.2 39.3
3×120 12.4 1.2 1.2 2 2.3 43
3×150 13.8 1.4 1.4 2.5 2.5 48.6
3×185 15.3 1.6 1.4 2.5 2.7 53
3×240 17.5 1.7 1.4 2.5 2.8 58.5
3×300 19.5 1.8 1.6 2.5 3 64
3×400 22.6 2 1.6 3.15 3.3 73.5

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3×120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3×150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3×185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3×240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3×300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8

 

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4×1.5 1.4 0.7 1 0.8 1.8 14
4×2.5 1.8 0.7 1 0.8 1.8 14.9
4×4 2.3 0.7 1 1.25 1.8 17
4×6 2.8 0.7 1 1.25 1.8 18.2
4×10 3.6 0.7 1 1.25 1.8 20.2
4×16 4.5 0.7 1 1.6 1.8 23
4×25 5.6 0.9 1 1.6 1.8 26.7
4×35 6.7 0.9 1 1.6 1.9 29.5
4×50 8 1 1 2 2.1 34.2
4×70 9.4 1.1 1.2 2 2.2 38.8
4×95 11 1.1 1.2 2 2.3 42.9
4×120 12.4 1.2 1.4 2.5 2.5 48.6
4×150 13.8 1.4 1.4 2.5 2.7 53.2
4×185 15.3 1.6 1.4 2.5 2.8 58.1
4×240 17.5 1.7 1.6 2.5 3.1 64.8
4×300 19.5 1.8 1.6 2.5 3.2 70.4
4×400 22.6 2 1.8 3.15 3.6 81.3

1). Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.

Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.0754 0.0601 0.047 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206 0.164 0.125 0.1 0.778 0.0605 0.0469 0.0367

 3). Voltage Test and Partial Discharge Test

Rate voltage Uo (kv)
Item
0.6/1 1.8/3 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test time 5 5 5 5 5 5 5 5 5
Partial discharge test Test voltage 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge capacity 10 10 10 10 10 10 10

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.

About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees’ number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ
Q:I didn’t find the product which I need in this page?
A:If you didn’t find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What’s your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What’s your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.

As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!

Just leave your message if you are interested in our products,We will contact you very soon!
 —————————————————–
 
 
 
Tel: +86 185 3857 5783 

—————————————————–

We are China Low-Toxicity Flame Retardant Shipboard Flexible Power Cable Hfix Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular kingyear Products

Overhead Power Transmission Line Aluminum AAC AAAC ACSR Acar Conductor

AAAC 740.8mcm 800mm2 95mm2 Overhead Transmission Line Used Cable Conductor

Single Core PVC Coated Copper Electric Cable Wire 6mm Electric Fireproof Electrical Wire

Power Transmission Line Conductor AAAC Conductor 312.8mcm Butte

Best Selling All Aluminum Conductor AAC Overhead Conductor

Bottom Price A7001 Aluminum Plate Price Per Ton

Popular Low Smoke Halogen Free Power Cable Products

Low Smoke Halogen Free Power Cable

Popular Low Voltage Power Cable Products

XLPE PVC Sheath Swa Power Cable

Single Core Low Voltage XLPE Cable, Copper Electric Power Cable Two Years Warranty

Low Voltage 50mm2 XLPE Insulation Steel Wire Armored Power Cable

1.1kv 3X70sqmm XLPE/PVC Armoured Power Cable

Low Voltage Underground Power Cable

0.6/1kv-4 Core Copper Conductor PVC Insulated Steel Wire Armored PVC Sheathed Power Cable Nyry

Popular Low-Smoke Flame Power Cable Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION