- Overview
- Product Description
- Product Parameters
- Company Profile
Basic Info.
Packaging & Delivery
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | |||||
Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
mm2 | – | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |
Al Conductor | Cu Conductor | ||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km |
Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | |
3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | |
3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | |
3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | |
3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | |
3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | |
3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | |
3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | |
Four Cores with Reduced Neutral | 3×35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | |
3×70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 | |
3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | |
3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | |
3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | |
3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | |
3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | |
3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | |
Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | |
4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | |
4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | |
4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | |
4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | |
4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | |
4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | |
4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | |
4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||
Al Conductor | Cu Conductor | |||||||
– | mm2 | – | mm | mm | mm | kg/km | kg/km | |
Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |
3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||
3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||
3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||
3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||
3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||
3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||
3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||
3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||
3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||
3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||
3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||
3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||
Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |
4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||
4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||
4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||
4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||
4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||
4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||
4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||
4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||
4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||
4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||
4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 |
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||||||
STA | SWA | |||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | |
Three Cores | ||||||||||||||
3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 | |
3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 | |
3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 | |
3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 | |
3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 | |
3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 | |
3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 | |
3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 | |
3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 | |
Four Cores with Reduced Neutral | ||||||||||||||
3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 | |
3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 | |
3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 | |
3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 | |
3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 | |
3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 | |
3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 | |
3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 | |
3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 | |
Four Cores | ||||||||||||||
4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 | |
4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 | |
4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 | |
4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 | |
4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 | |
4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 | |
4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 | |
4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 | |
4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 | |
4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
STA | SWA | ||||||||||||
STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
Three Cores | |||||||||||||
3×10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
3×16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
3×25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
3×35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
3×50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
3×70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
3×95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
3×120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
3×150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
3×185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
3×240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
3×300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
3×400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
Four Cores | |||||||||||||
4×10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
4×16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
4×25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
4×35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
4×50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
4×70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
4×95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
4×120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
4×150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
4×185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
4×240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
4×300 | 61 | 2.4 | 1.6 | 0.5 | 61/3.15 | 3.4 | 3.5 | 74.7 | 78.8 | 7346 | 14735 | 10305 | 17694 |
We are China Low Voltage XLPE PVC Insulated Aluminum Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
Na2xsfy 3*70sqmm 185sqmm 300sqmm 12/20kv 18/30kv Power Cable
4 Cores Frc Fire Resistant Cable XLPE Insulation LSZH Sheathed 0.6/1kv
Covered Line Wire with ASTM Standard Overhead Conductor
DIN Standard 16/25/35/50 Sqmm Overhead All Aluminium Alloy Conductor AAAC
XLPE Inulsted Yjlv Cable 50 70 95 120 150 Sq mm2 Power Cable
IEC60502 Standard 1kv Aerial Bundled ABC Cable
Popular jpcable99 Products
ABC Cable/Aluminum Conductor/Triplex Service Drop Wire/ASTM Standard"Haiotis"
ACSR "Zebra" Conductor Bare Cable
2 Core 16mm2 Aluminium Cable AAC/XLPE
Nyy Power and Control Cable for Fixed Installation HD 603 DIN VDE 0276 Bs 6346
54.6 Sqmm AAAC All Aluminium Alloy Conductor
High Quality BS215 Standard ACSR Conductor
Popular Low Voltage XLPE PVC Insulated Aluminum Power Cable Products
Popular Power Cable Products
600/1000V, Power Cable, Armour, XLPE Insulated, PVC Sheath
H07V2-U Wire Electrical Cable PVC Building Wire Electric Wire
Outdoor Waterproof Electrical Copper Power Cable for Industrial Yjv22 0.6/1kv Armored Power Cable
4X120 + 1X70 mm2 N2xy, Power Cable, 0.6/1 Kv, Cu/XLPE/PVC
Multicore XLPE Insulation Black Silicone Copper Flexible Rubber Cable
Tags: Cable, jpcable99, Low Voltage XLPE PVC Insulated Aluminum Power Cable, Power Cable