Lw3-12 I. II Sf6 Hv Outdoor Circuit Breaker 12kv
Lw3-12 I. II Sf6 Hv Outdoor Circuit Breaker 12kv image
Get Latest Price Request a quote
Basic Info.
Product Description
General:
LW3-12 I. II SF6 HV outdoor circuit breaker is a new type product that SF6 is taken for insulating and arc
extinguishing. The arc-chute consists of a breaker and an operative mechanism, using rotating arc principle.
Compared with the 10KV series outdoor breakers, this kind of product has obvious advantages, such as a
simple structure, the higher reliability of insulating and arc extinguishing, a lower operative power, and a higher
rated parameter, a longer electrical service life, a long maintenance free duration, and so on.
This kind of product can be divided into two types: Type I and Type II. The main difference is that, type I is fitted
with a kind of manual energy -storage mechanism operated by spring, mainly used on the pillar, and type II is
equipped with motor-driven energy -storage mechanism operated by spring which not only can be operated by
hand directly or be controlled remote, but also can do coincide automatically, mainly used in the mini-medium
substation for protecting and controlling.
Technical parameters:
| NO | Name | Unit | Data | |
| 1 | Rated voltage | KV | 12 | |
| 2 | Rated insulating level (the pressure of SF6 in the breaker is 0.25Mpa, the temperature is 20 ) | Lightning impulse withstand voltage (full wave) | KV | 75 |
| Rated 1min power frequency withstand voltage | 42 | |||
| The voltage withstand test under the condition of raining | 34 | |||
| 3 | The insulating level under zero pressure (the pressure on the highest phase is 5min) |
KV | 9 | |
| 4 | Rated current | A | 400 630 | |
| 5 | Rated short-circuit breaking current | KA | 6.3 8 12.5 | |
| 6 | The breaking current under zero pressure of t | A | 400 630 | |
| 7 | Rated short-circuit breaking times | Times | 20 | |
| 8 | Rated operative sequence | Type I | Off-180s-on/off- 180s- on/off |
|
| Type II | Off -0.5s- on/off – 180s- on/off |
|||
| 9 | Rated short-circuit breaking current (peak value) | KA | 16 20 31.5 | |
| 10 | Rated peak withstand current (peak value) | KA | 16 20 31.5 | |
| 11 | Rated short-time withstand time | S | 4 | |
| 12 | Rated short-time withstand current | KA | 6.3 8 12.5 | |
| 13 | Rated operating pressure | M Pa | 0.35 | |
| 14 | The lowest operating pressure | M Pa | 0.25 | |
| 15 | Annual leak rate | & | < =1 | |
| 16 | Mechanical Endurance | Times | 2000 | |
| 17 | Weight | Type I | Kg | 122 |
| Type II | 130 | |||
Other series:
Our Services
| 1. | Pre sale service |
| a. | make technical solution |
| b. | send quotation, technical data sheet and drawing |
| c. | prepare power transmission plan, testing plan,and shipment plan |
| 2. | In sale service |
| a. | supervise the manufacturing schedule totally in accordance with the plan |
| b. | send photos to customer during every manufacturing process(hold point) |
| c. | inform the customer one week before testinng. |
| 3. | After sale service |
| a. | installation and commissioning, training the workers |
| b. | quick response within 12 hours any time |
| c. | provide 12 months gurantee period normally. |
FAQ
| 1. Q: | What is your delivery time ? |
| A: | Depend on the type of transformer. |
| 2. Q: | What is your payment term? |
| A: | 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
| 3. Q: | What kind of starndard you follow? |
| A: | IEC, ANSI, CSA, GB, etc |
| 4. Q: | What kind of supporting documentation you can provide normally |
| A: | Quotation,outline drawing,manufacturing plan, quality control plan testing plan, financial report, type test report(KEMA, CESI),reference list,etc |
| 5. Q: | What is your normal wanrranty period? |
| A: | 12 months after transformer operation. |
| 6. Q: | Can u do installation and commissioningin user’s site? |
| A: | Yes, we can send our installation team to user’s country for service. |
| 7. Q: | Do you have any experience in this kind of transformer? |
| A: | Yes, we can provide reference list for check. |
| 8. Q: | Are you manufacturer or trading company? |
| A: | Manufacturer with own import & export company. |
Our advantages:
Quality Assurance
–From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
–With more than 30 years’ experience in power industry, VILLE brings you an optimized solution.
Global Service
–Wherever you are, VILLE global network will support and provide you with value.
Quick Response
–In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Lw3-12 I. II Sf6 Hv Outdoor Circuit Breaker 12kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Circuit Breaker Products
Outdoor Sf6 Gas Circuit Breaker
Factory 1200V 1500V DC Molded Case Circuit Breaker Electronic MCCB 63A 80A 100A 125A Price
VBI-12kv Indoor Vcb Front Mounted Vacuum Interrupters for Circuit Breaker
Lw24-72.5kv Dead Tank Circuit Breaker
Popular Circuit Breaker 12kv Products
Popular cnville Products
Sfs10-6300/110 6300kVA 110kv 6.6kv Three-Winding No-Excitation Tapping Power Transformer
Sfz-4200000/220kv Power Transformer/Oil Immersed Power Transformer
160kw Medium Frequency Induction Melting Furnace
Box Type Operation Cabinet /Low Power Distribution Box Voltage Switchgear
Hsspz-120000/35 120mva 35kv Arc Furnace Transformer
S9-4000/35 4mva S9 Series 35kv Power Transformer with on Load Tap Changer