PRODUCT CONSTRUCTION
Conductor: 6 AWG through 1000 kcmil bare annealed copper per ASTM B3. Compact stranding per ASTM B496. Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072.
Insulation: 115 mil Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072.
Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072.
Shield: 5 mil annealed bare copper tape with 25% overlap.
Grounding Conductor(s): Three split Class B stranded bare annealed copper ground conductors sized in accordance with UL 1072 and NEC Article 250.
Armor: Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and 1569. Meets grounding requirements of NEC Article 250.
Jacket: Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow. Low-temperature performance meets ASTM D746 brittleness temperature at or below -40ºC.
APPLICATIONS
Variable Frequency Drives: 3-conductor CCW armored cables with three symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications.
For use in Class I, II and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505. For installation on metal racks, troughs, in raceways and cable trays, or secured to supports not more than six feet apart. For exposed and concealed work in wet or dry locations, directly buried or embedded in concrete. For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330.
FEATURES
Armor provides impervious barrier to moisture, gas and liquids.
The strand shield, EPR insulation and insulation shield are extruded in one operation.
The EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress. Meets cold impact test at -40ºC.
COMPLIANCES
Industry: UL Type MV-105. UL Type MC-HL, XHHW-2, CT USE, SUN RES, DIR BUR -40ºC, FT4.
UL Listed Marine Shipboard, American Bureau of Shipping (ABS) Listed for CWCMC.
Design Adherence:
ICEA S-93-639/WC74, 5-46 kV Shielded Power Cable.
AEIC CS8 Specification for Shielded Power Cable, 5-46 kV.
UL 1072 Medium-Voltage Power Cables.
UL 1569 Metal Clad Cables.
UL 2225 Cables and Cable Fittings for Use in Hazardous Locations.
UL 1309 Marine Shipboard Cable.
UL C68.3 Flame Tests: ICEA T-29-520 (210,000 BTU/hr). IEEE 383 (70,000 BTU/hr).
UL FT4.
IEEE 1202 (70,000 BTU/hr).
UL 1072. IEC 60332-3 Category A.
| Size (AWG or Kcmil) | No. of Strands | Insul. Thick. (Mils) | Nom. Diam. Over Armor | PVC Jkt. | Nom. Diam. Over PVC Jkt. | Copper Phase Conductors | ||||
| Copper Grounding Conductor (AWG) | Weight (lbs./1000 ft.) | Ampacity | ||||||||
| (Inches) | Thick (Mils) | (Inches) | Net | Copper | In Air | Direct Burial | ||||
| 5000 VOLTS – 133% INSULATION LEVEL or 8000 VOLTS – 100% INSULATION LEVEL | ||||||||||
| 4 | 7 | 115 | 1.51 | 60 | 1.65 | 3 X #10 | 1418 | 616 | 115 | 150 |
| 2 | 7 | 115 | 1.64 | 60 | 1.78 | 3 X #10 | 1731 | 860 | 154 | 190 |
| 1 | 19 | 115 | 1.69 | 60 | 1.82 | 3 X #8 | 1978 | 1074 | 180 | 215 |
| 1/0 | 19 | 115 | 1.78 | 60 | 1.91 | 3 X #8 | 2259 | 1290 | 205 | 245 |
| 2/0 | 19 | 115 | 1.92 | 60 | 2.05 | 3 X #8 | 2626 | 1556 | 240 | 280 |
| 4/0 | 19 | 115 | 2.15 | 60 | 2.28 | 3 X #7 | 3650 | 2344 | 320 | 360 |
| 250 | 37 | 115 | 2.23 | 60 | 2.36 | 3 X #7 | 4060 | 2759 | 355 | 395 |
| 350 | 37 | 115 | 2.45 | 75 | 2.61 | 3 X #6 | 5045 | 3713 | 440 | 475 |
| 500 | 37 | 115 | 2.75 | 75 | 2.92 | 3 X #5 | 7137 | 5191 | 545 | 570 |
| 750 | 61 | 115 | 3.32 | 85 | 3.5 | 3 X #4 | 10268 | 7629 | 685 | 700 |
| 1000 | 61 | 115 | 3.76 | 85 | 3.94 | 3 X #4 | 13051 | 10070 | 790 | 785 |
We are China Mc-Hl Metal-Clad Cable for Hazardous Locations as Defined in UL 2225 Standard 3 Conductor 2/0 4/0AWG EPDM/PVC Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Ccw Cable Products
Oil and Gas Armored UL Mv Mc-Hl Aia Armoured 5kv Cable
Armored Ht Cables Armor UL Mc Hl Mchl Mv 5kv Cable Manufacturer Mc-Hl
3/C Al 15kv 220 Nl-Epr 133% Ts PVC Mv-105 Cable for Canada
Mc-Hl Armored 5kv UL Mc Hl Mchl Mv Ccw Power Armor Cable
Popular huatongcables Products
Nm90 Copper Building Wire cUL Certificate for Elecatircal Wire
PVC Building Flat Wire House Electric Wires Nm-B Manufacture
Urd Mv-90 100% 133% Trxlpe Insulation Single Core Cable High Voltage Cable
Canada 3c 4c 250/3 Canadian Building Wire XLPE Insulation Acm Acwu90 Cable
UL 854 600V XLPE Insulation Mobile Urd Home Feeder Cable
Manufacture UL 4703 Standard Solar Cable Energy System Alulminum PV Rhh Wire
Popular Mc-Hl Cable Products
Mc-Hl Cable Continuously Corrugated Welded Cable Type 15kv 25kv 35kv 250mcm Aia Armour Mc Hl Cable
Ht Cables Armored Power 5kv UL Mc Hl Armor Ccw Cable Mc-Hl
Mc-Hl Armored Ccw Power 5kv Armor UL Mc Hl Mchl Mv Cable
Copper Conductor Continuously Welded Sheath (MC-HL) PVC Sheath Power Cable
Mc-Hl Armored 5kv UL Mc Hl Mchl Mv Ccw Power Armor Cable