Medium Voltage Mv XLPE Insulated PVC Sheathed Power Cable
Medium Voltage Mv XLPE Insulated PVC Sheathed Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
1.Application
1)XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables.
2)XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has a simple structure, convenient operation and it is not restricted by laying in a large difference of level.
3) It can be applied at a high temperature of 90 degrees for a long time.
4)Flame-retardant and non-flame-retardant XLPE cables can be manufactured by three kinds of technological processes: peroxidation, silanization, and irradiation.
5)The flame-retardant cable covers three classes of A, B, C, and low-smoke low-halogen, low-smoke non-halogen cables.
2.Standard
Our XLPE cable is produced according to IEC 60502, IEC60332, and IEC 60754, even some of our indexes are superior to the above international IEC standards. Meanwhile, we can produce cables according to other standards and can design the XLPE cables with some certain special properties according to customers’ requirements.
XLPE cable can be applied at high temperatures for a long time and has a bigger current capacity. In the same environmental conditions, compared with paper insulated and PVC insulated cables, XLPE cable can lessen the cross-section by 1 or 2 grades.
3.Specification
We can make it according to IEC, BS, VDE,AS/NZS, ICEA, JIS and so on;
1)0.6/1kV, Single Core, Cu or Al/XLPE/PVC Power Cable;
0.6/1kV, Single Core, Cu or Al/XLPE/PVC/AWA/PVC Power Cable
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | The diameter of Al Wires | Nominal Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight | |||||
| Cu Conductor | Al Conductor | |||||||||||
| AWA | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | |||
| mm2 | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| 1.5 | 1.6 | 0.7 | – | – | 1.4 | – | 5.7 | – | 44 | – | – | – |
| 2.5 | 2.0 | 0.7 | – | – | 1.4 | – | 6.2 | – | 57 | – | – | – |
| 4 | 2.6 | 0.7 | – | – | 1.4 | – | 6.7 | – | 74 | – | – | – |
| 6 | 3.1 | 0.7 | – | – | 1.4 | – | 7.3 | – | 96 | – | – | – |
| 10 | 3.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 7.9 | 12.4 | 134 | 235 | 74 | 175 |
| 16 | 4.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 8.9 | 13.4 | 196 | 307 | 99 | 209 |
| 25 | 6.0 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 10.6 | 15.1 | 289 | 417 | 139 | 267 |
| 35 | 7.1 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 11.7 | 16.2 | 382 | 522 | 172 | 309 |
| 50 | 8.4 | 1.0 | 1.0 | 1.25 | 1.4 | 1.5 | 13.2 | 18.7 | 503 | 710 | 220 | 427 |
| 70 | 10.0 | 1.1 | 1.0 | 1.25 | 1.4 | 1.5 | 15.0 | 20.5 | 702 | 936 | 293 | 522 |
| 95 | 11.7 | 1.1 | 1.0 | 1.25 | 1.5 | 1.5 | 16.8 | 22.4 | 950 | 1209 | 384 | 638 |
| 120 | 13.3 | 1.2 | 1.0 | 1.6 | 1.5 | 1.6 | 18.6 | 25.1 | 1186 | 1531 | 469 | 806 |
| 150 | 14.5 | 1.4 | 1.0 | 1.6 | 1.5 | 1.6 | 20.4 | 26.7 | 1458 | 1820 | 567 | 923 |
| 185 | 16.4 | 1.6 | 1.0 | 1.6 | 1.5 | 1.7 | 22.7 | 29.2 | 1810 | 2219 | 698 | 1105 |
| 240 | 18.7 | 1.7 | 1.0 | 1.6 | 1.6 | 1.8 | 25.4 | 31.9 | 2348 | 2802 | 889 | 1335 |
| 300 | 20.4 | 1.8 | 1.0 | 1.6 | 1.7 | 1.8 | 27.4 | 33.7 | 2917 | 3393 | 1091 | 1568 |
| 400 | 23.2 | 2.0 | 1.2 | 2.0 | 1.8 | 2.0 | 30.9 | 38.5 | 3713 | 4377 | 1379 | 2043 |
| 500 | 26.4 | 2.2 | 1.2 | 2.0 | 1.9 | 2.1 | 34.7 | 42.3 | 4770 | 5512 | 1767 | 2510 |
| 630 | 30.0 | 2.4 | 1.2 | 2.0 | 2.1 | 2.2 | 39.1 | 46.5 | 6105 | 6914 | 2248 | 3058 |
| 800 | 34.0 | 2.6 | 1.4 | 2.5 | 2.2 | 2.4 | 43.6 | 52.6 | 7893 | 9008 | 2867 | 3981 |
| 1000 | 41.4 | 2.8 | 1.4 | 2.5 | 2.3 | 2.5 | 51.6 | 60.8 | 10189 | 11524 | 3690 | 5025 |
2.)0.6/ 1kV ,3C+E Cores, Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+E Cores, Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+E Cores, Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
| Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable | |||||||||||
| Cu Conductor | Al Conductor | ||||||||||||||||||
| STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km | ||||
| mm2 | mm | mm | mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
| 1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | – | – | – |
| 2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | – | – | – |
| 4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | – | – | – |
| 6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | – | – | – |
| 10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
| 16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
| 25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.6 | 25.4 | 28.7 | 1064 | 1318 | 1890 | 514 | 769 | 1340 |
| 35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.6 | 27.4 | 30.7 | 1340 | 1617 | 2241 | 610 | 883 | 1509 |
| 50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.4 | 31.4 | 34.7 | 1808 | 2139 | 2870 | 807 | 1134 | 1851 |
| 70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 29.7 | 32.6 | 37.3 | 2446 | 2789 | 3831 | 988 | 1309 | 2280 |
| 95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.7 | 38.1 | 41.1 | 3313 | 4049 | 4865 | 1307 | 2000 | 2764 |
| 120 | 13.3 | 1.2 | 70 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 36.3 | 40.9 | 43.9 | 4223 | 5033 | 5913 | 1631 | 2396 | 3223 |
| 150 | 14.5 | 1.4 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 41.3 | 46.0 | 50.2 | 5061 | 5993 | 7415 | 1940 | 2826 | 4190 |
| 185 | 16.4 | 1.6 | 95 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 46.6 | 51.4 | 55.6 | 6400 | 7446 | 9076 | 2453 | 3454 | 4983 |
| 240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 52.4 | 57.3 | 61.8 | 8291 | 9484 | 11337 | 3137 | 4284 | 6032 |
| 300 | 20.4 | 1.8 | 150 | 1.5 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.8 | 58.0 | 63.0 | 67.1 | 10322 | 11659 | 13632 | 3864 | 5155 | 7058 |
Product Pictures:
Packing and Delivery:
Our Company:
People’s Cable Group Co., Ltd, a professional wires and cables manufacturer for 27 years in China. we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR, and AAAC cables), etc. Standards Supported: ASTM, BS, CSA, IEC, DIN, and GB, etc.
1. Factory: 160000 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, ISO9001:2008;
4. Guarantee: 20 years;
5. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
FAQ:
(1)When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2)How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. The sample is free, but the freight charge should be paid.
(3)How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7days. The samples will be sent to you via express and arrive in 3-5 days. You can use your own express account or prepay us if you do not have an account.
(4)What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start an inquiry two months before the date you would like to get the products in your country.
Contact Information:
Ivan Fan | Sales Manager | People’s Cable Group
Web: renmincable.en.
Web: renmincable.en.
If you have any questions, please contact me, I will reply to you as soon as possible.
Welcome to your inquiry.
We are China Medium Voltage Mv XLPE Insulated PVC Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
High Quality 110kv-132kv Porcelain Type Outdoor Terminal for Substation with CE
Installation of Competitive Price High Grade Aerial Bundled Cable
16mm 4core Aluminum/Copper Dsta Armored PVC Sheath Electric Cable
33kv XLPE Power Cable Single Core Mv Cable
BS Standard Overhead Bare Conductor ACSR Dog Conductor
UL Certified Single Cores Urd 5kv/8kv/15kv/35kv Power Cable
Popular Electric Cable Products
ABC Cable, Aluminium Conductor XLPE/PE Insulated Aerial Bundled Cable.
XLPE Insulated Electric Cable Aluminum Conductor
Thhn Cable 12AWG Thwn-2 Thwn Nylon PVC UL Electric Wires Cables for Building and House
Low Voltage Weather Resistance XLPE Insulated Aluminum Conductor ABC Cable
Duplex Triplex Quadruple Aluminium Conductor XLPE PE Insulated Overhead ABC Cable.
Overhead Insulation ABC Cable for Power Transmission
Popular renmincable Products
ASTM B416 High Conductivity Alumoweld Conductor Aluminum Clad Steel Wire Acs
0.6/1kv Yjv Electrical Power Cable XLPE Building 3X2.5mm2 Power Cable 4X25mm2
35mm 70 mm 1kv XLPE Underground Amored Yjv22 Yjlv22 PVC Sheathed Power Electricity Cable
Electric Wire PVC House Wiring Electrical Cable Electric Wire Manufacturer
XLPE Insulated Armoured 95mm2 Power Cable Manufacturer
Competitive Price Electrical Cable Wire 2.5mm H07V-R H07V-U, H05V-R H05V-U
Popular XLPE Cable Products
Electric Power Cable Underground High Voltage Power Cable 15kv 25kv 35kv
0.6/1kv Copper Conductor PVC or XLPE Insulated Power Cable
Low Voltage Power Cable Lead Sheath 10X2.5 mm2
11kv 35kv Middle Voltage PVC/PE Sheathed XLPE Insulated Cable Copper Cable
1X150mm2 Aluminum Stranded Conductor 26/45kV AL/XLPE/CWS/LSOH Cable IEC60840 for Transformer
3Cx240sq.mm 11kV CU/XLPE/SWA/PVC Copper Armoured MV Underground Power Cable for 33/11kV Substation