Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection

China 
                 Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection
              manufacture and supplier

Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection image

Get Latest Price Request a quote

Basic Info.

Model NO.
HY10W-33

Application
Substation

Size
Meidum

Operation Voltage
High Voltage

Shape
Spiral

Material
ZnO

Certification
ISO9001

Brand
L&R

Transport Package
Cartoon/Wooden Box

Trademark
L&R

Origin
China

Production Capacity
9000PCS/Month

Product Description

SURGE ARRESTERS

Application:
Massive productions of surge arrester (MOA), either with porcelain or polymeric housing, are suitable in the systems of power generation, power transmission, power transformation, and power distribution under AC 220kV and below. They are mainly used to keep the amplitude of lighting impulse withstand voltage and switching impulse withstand voltage to the prescribed level.
Keystone:
Surge arrester is the most advanced over-voltage protector in the world. Its core element, metal oxide varistor (MOV).
Under the circumstance of normal operating voltage, the current through the surge arrester is just on microampere degree. When suffered from over-voltage, the surge arrester’ s excellent non-linear characteristic will make the current through the surge arrester increase to several thousand amperes. And the surge arrester will be under the circulating state and release over-voltage energy so as to protecting the power transmission equipment against the damage caused by the over-voltage.
Condition of Use:
1. Ambient air temperature within the range of -40ºC to +40ºC;
2. Altitude above sea level not exceeding 2,000m;
3. Frequency of the A.C. power supply being 50Hz or 60Hz;
4. Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage:
5. Maximum wind speed not exceeding 35m/s:
6. The earthquake intensity not exceeding 7 degrees.

Characteristics:
-Low residual voltage
-Long protection distance
-High energy input capacity
-Stable volt-ampere characteristic even after multiple strokes
-Proof against ageing
-Explosion and shatter-resistant design
-Pollution resistant and UV-stable
-Housing resistant to rough handling
-Maintenance free
-Stable against shock and vibration
-High mechanical resistance

Technical Standard:
The technical performance of the products is in confirmed to IEC60099-4.

Main technical Parameters:

Type Rated voltage Maximun
Continuous
Operating
Voltage
1/4us
Lightning
Current
impulse
8/20us
Lightning
Current
impulse
30/60us
Switching
Current
impulse
2ms Rectangular
current impulse
withstand
4/10us High
current impulse
withstand
kV kV kV(peak) kV(peak) kV(peak) A kA(crest)
HY5W-3 3 2.55 11.3 9 8.9 120-200 65-75
HY5W-6 6 5.1 22.6 18 16.8 120-200 65-75
HY5W-9 9 7.65 33.7 27 23.8 120-200 65-75
HY5W-10 10 8.4 36.0 30 23 120-200 65-75
HY5W-11 11 9.4 40.0 33 30 120-200 65-75
HY5W-12 12 10.2 42.2 36 27 120-200 65-75
HY5W-15 15 12.7 51.0 45 38.5 120-200 65-75
HY5W-18 18 15.3 61.5 54 46.2 120-200 65-75
HY5W-21 21 17.0 71.8 63 54.2 120-200 65-75
HY5W-24 24 19.5 82.0 72 62 120-200 65-75
HY5W-27 27 22.0 92.0 81 69.8 120-200 65-75
HY5W-30 30 24.4 102.0 90 79 120-200 65-75
HY5W-33 33 27.5 112.0 99 86.7 120-200 65-75
HY5W-36 36 29.0 123.0 108 95.4 120-200 65-75
HY5W-42 42 34.1 132.3 126 100.1 120-200 65-75




Used for 10kA Distribution Class 1:

 

Type Rated voltage Maximun
Continuous
Operating
Voltage
1/4us
Lightning
Current
impulse
8/20us
Lightning
Current
impulse
30/60us
Switching
Current
impulse
2ms Rectangular
current impulse
withstand
4/10us High
current impulse
withstand
kV kV kV(peak) kV(peak) kV(peak) A kA(crest)
HY10W-3 3 2.55 11.3 9 8.9 250-400 100
HY10W-6 6 5.1 22.6 18 16.8 250-400 100
HY10W-9 9 7.65 33.7 27 23.8 250-400 100
HY10W-10 10 8.4 36.0 30 23 250-400 100
HY10W-11 11 9.4 40.0 33 30 250-400 100
HY10W-12 12 10.2 42.2 36 27 250-400 100
HY10W-15 15 12.7 51.0 45 38.5 250-400 100
HY10W-18 18 15.3 61.5 54 46.2 250-400 100
HY10W-21 21 17.0 71.8 63 54.2 250-400 100
HY10W-24 24 19.5 82.0 72 62 250-400 100
HY10W-27 27 22.0 92.0 81 69.8 250-400 100
HY10W-30 30 24.4 102.0 90 79 250-400 100
HY10W-33 33 27.5 112.0 99 86.7 250-400 100
HY10W-36 36 29.0 123.0 108 95.4 250-400 100
HY10W-42 42 34.1 133.0 126 100.1 250-400 100

Used for 10kA Distribution Class 2:

 

Type Rated voltage Maximun
Continuous
Operating
Voltage
1/4us
Lightning
Current
impulse
8/20us
Lightning
Current
impulse
30/60us
Switching
Current
impulse
2ms Rectangular
current impulse
withstand
4/10us High
current impulse
withstand
kV kV kV(peak) kV(peak) kV(peak) A kA(crest)
HY10W-3 3 2.55 10 9 8 250-400 100
HY10W-6 6 5.1 20 18 16 250-400 100
HY10W-9 9 7.65 31 27 24 250-400 100
HY10W-10 10 8.4 35 30 26 250-400 100
HY10W-11 11 9.4 38 33 29 250-400 100
HY10W-12 12 10.2 41 36 32 250-400 100
HY10W-15 15 12.7 51 45 40 250-400 100
HY10W-18 18 15.3 62 54 48 250-400 100
HY10W-21 21 17.0 72 63 56 250-400 100
HY10W-24 24 19.5 82 72 64 250-400 100
HY10W-27 27 22.0 93 81 72 250-400 100
HY10W-30 30 24.4 103 90 81 250-400 100
HY10W-33 33 27.5 113 99 89 250-400 100
HY10W-36 36 29.0 124 108 97 250-400 100
HY10W-42 42 34.1 145 126 113 250-400 100










Used for 10kA Power station/Substation Class 2:

 

Type Rated voltage Maximun
Continuous
Operating
Voltage
1/4us
Lightning
Current
impulse
8/20us
Lightning
Current
impulse
30/60us
Switching
Current
impulse
2ms Rectangular
current impulse
withstand
4/10us High
current impulse
withstand
kV kV kV(peak) kV(peak) kV(peak) A kV(crest)
HY10W-60 60 48 208 180 160 600-900 100
HY10W-66 66 52.8 230 198 172 600-900 100
HY10W-72 72 57.6 252 216 184 600-900 100
HY10W-78 78 62.4 274 234 196 600-900 100
HY10W-84 84 67.2 296 252 208 600-900 100
HY10W-90 90 72 318 270 220 600-900 100
HY10W-96 96 76.8 340 288 232 600-900 100
HY10W-102 102 81.6 362 306 244 600-900 100
HY10W-108 108 86.4 384 324 256 600-900 100
HY10W-120 120 96 428 360 280 600-900 100
HY10W-150 150 120 538 450 340 600-900 100
HY10W-200 200 160 720 600 440 600-900 100

 
/* May 10, 2024 16:49:51 */
!function(){function d(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular laurenceelectirc Products

Mini European Style Crimping Plier Pipe Crimping Tool/Hsc8 6-6

Dtl-1 Series Electric Bimetallic Lug

Socket Thimble; ; ;

Nek, Nxl (NEL, NK) Insulation Strain Clamp (wedge type)

Prw-11 Drop-out Fuse Cutout; Power Tool

Fn12-12 Series Indoor Use High Voltage Load Switch

Popular Lightning Protection Products

Electrical Component Light Diverter Lightning Protection with Cap

Silicon Rubber (Porcelain) Housed Metal Oxide Surge Arrester Kema Report

Polymeric Housing Metal Oxide Surge Arrester for Low Voltage System

Zinc Oxide Arrester/Substation Surge Arrester/Hangzhou Professional Manufacture

Lightning Protection Products Silicone Arrester with Kema Type Test Report

Lower Voltage Arrestor Polymeric Surge Arrestor Polymer Lightning Arresters

Popular Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection Products

  • No related articles
  • Popular Surge Arrester Products

    35kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric 15kv 22kv 33kv 36kv High Voltage Porcelain Ceramic Station

    Kema Composite 10kv-33kv Lightning Arrester 10ka

    Polymer Housed Metal Oxide Surge Arrester Without Gaps

    Polymeric Housed Metal-Oxide 11kv Surge Arrester

    High Voltage Power Transmission Lightning Arrester

    High Voltage Substation Lightning Arresters

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION