SURGE ARRESTERS
Application:
Massive productions of surge arrester (MOA), either with porcelain or polymeric housing, are suitable in the systems of power generation, power transmission, power transformation, and power distribution under AC 220kV and below. They are mainly used to keep the amplitude of lighting impulse withstand voltage and switching impulse withstand voltage to the prescribed level.
Keystone:
Surge arrester is the most advanced over-voltage protector in the world. Its core element, metal oxide varistor (MOV).
Under the circumstance of normal operating voltage, the current through the surge arrester is just on microampere degree. When suffered from over-voltage, the surge arrester’ s excellent non-linear characteristic will make the current through the surge arrester increase to several thousand amperes. And the surge arrester will be under the circulating state and release over-voltage energy so as to protecting the power transmission equipment against the damage caused by the over-voltage.
Condition of Use:
1. Ambient air temperature within the range of -40ºC to +40ºC;
2. Altitude above sea level not exceeding 2,000m;
3. Frequency of the A.C. power supply being 50Hz or 60Hz;
4. Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage:
5. Maximum wind speed not exceeding 35m/s:
6. The earthquake intensity not exceeding 7 degrees.
Characteristics:
-Low residual voltage
-Long protection distance
-High energy input capacity
-Stable volt-ampere characteristic even after multiple strokes
-Proof against ageing
-Explosion and shatter-resistant design
-Pollution resistant and UV-stable
-Housing resistant to rough handling
-Maintenance free
-Stable against shock and vibration
-High mechanical resistance
Technical Standard:
The technical performance of the products is in confirmed to IEC60099-4.
Main technical Parameters:
| Type | Rated voltage | Maximun Continuous Operating Voltage |
1/4us Lightning Current impulse |
8/20us Lightning Current impulse |
30/60us Switching Current impulse |
2ms Rectangular current impulse withstand |
4/10us High current impulse withstand |
| kV | kV | kV(peak) | kV(peak) | kV(peak) | A | kA(crest) | |
| HY5W-3 | 3 | 2.55 | 11.3 | 9 | 8.9 | 120-200 | 65-75 |
| HY5W-6 | 6 | 5.1 | 22.6 | 18 | 16.8 | 120-200 | 65-75 |
| HY5W-9 | 9 | 7.65 | 33.7 | 27 | 23.8 | 120-200 | 65-75 |
| HY5W-10 | 10 | 8.4 | 36.0 | 30 | 23 | 120-200 | 65-75 |
| HY5W-11 | 11 | 9.4 | 40.0 | 33 | 30 | 120-200 | 65-75 |
| HY5W-12 | 12 | 10.2 | 42.2 | 36 | 27 | 120-200 | 65-75 |
| HY5W-15 | 15 | 12.7 | 51.0 | 45 | 38.5 | 120-200 | 65-75 |
| HY5W-18 | 18 | 15.3 | 61.5 | 54 | 46.2 | 120-200 | 65-75 |
| HY5W-21 | 21 | 17.0 | 71.8 | 63 | 54.2 | 120-200 | 65-75 |
| HY5W-24 | 24 | 19.5 | 82.0 | 72 | 62 | 120-200 | 65-75 |
| HY5W-27 | 27 | 22.0 | 92.0 | 81 | 69.8 | 120-200 | 65-75 |
| HY5W-30 | 30 | 24.4 | 102.0 | 90 | 79 | 120-200 | 65-75 |
| HY5W-33 | 33 | 27.5 | 112.0 | 99 | 86.7 | 120-200 | 65-75 |
| HY5W-36 | 36 | 29.0 | 123.0 | 108 | 95.4 | 120-200 | 65-75 |
| HY5W-42 | 42 | 34.1 | 132.3 | 126 | 100.1 | 120-200 | 65-75 |
Used for 10kA Distribution Class 1:
| Type | Rated voltage | Maximun Continuous Operating Voltage |
1/4us Lightning Current impulse |
8/20us Lightning Current impulse |
30/60us Switching Current impulse |
2ms Rectangular current impulse withstand |
4/10us High current impulse withstand |
| kV | kV | kV(peak) | kV(peak) | kV(peak) | A | kA(crest) | |
| HY10W-3 | 3 | 2.55 | 11.3 | 9 | 8.9 | 250-400 | 100 |
| HY10W-6 | 6 | 5.1 | 22.6 | 18 | 16.8 | 250-400 | 100 |
| HY10W-9 | 9 | 7.65 | 33.7 | 27 | 23.8 | 250-400 | 100 |
| HY10W-10 | 10 | 8.4 | 36.0 | 30 | 23 | 250-400 | 100 |
| HY10W-11 | 11 | 9.4 | 40.0 | 33 | 30 | 250-400 | 100 |
| HY10W-12 | 12 | 10.2 | 42.2 | 36 | 27 | 250-400 | 100 |
| HY10W-15 | 15 | 12.7 | 51.0 | 45 | 38.5 | 250-400 | 100 |
| HY10W-18 | 18 | 15.3 | 61.5 | 54 | 46.2 | 250-400 | 100 |
| HY10W-21 | 21 | 17.0 | 71.8 | 63 | 54.2 | 250-400 | 100 |
| HY10W-24 | 24 | 19.5 | 82.0 | 72 | 62 | 250-400 | 100 |
| HY10W-27 | 27 | 22.0 | 92.0 | 81 | 69.8 | 250-400 | 100 |
| HY10W-30 | 30 | 24.4 | 102.0 | 90 | 79 | 250-400 | 100 |
| HY10W-33 | 33 | 27.5 | 112.0 | 99 | 86.7 | 250-400 | 100 |
| HY10W-36 | 36 | 29.0 | 123.0 | 108 | 95.4 | 250-400 | 100 |
| HY10W-42 | 42 | 34.1 | 133.0 | 126 | 100.1 | 250-400 | 100 |
Used for 10kA Distribution Class 2:
| Type | Rated voltage | Maximun Continuous Operating Voltage |
1/4us Lightning Current impulse |
8/20us Lightning Current impulse |
30/60us Switching Current impulse |
2ms Rectangular current impulse withstand |
4/10us High current impulse withstand |
| kV | kV | kV(peak) | kV(peak) | kV(peak) | A | kA(crest) | |
| HY10W-3 | 3 | 2.55 | 10 | 9 | 8 | 250-400 | 100 |
| HY10W-6 | 6 | 5.1 | 20 | 18 | 16 | 250-400 | 100 |
| HY10W-9 | 9 | 7.65 | 31 | 27 | 24 | 250-400 | 100 |
| HY10W-10 | 10 | 8.4 | 35 | 30 | 26 | 250-400 | 100 |
| HY10W-11 | 11 | 9.4 | 38 | 33 | 29 | 250-400 | 100 |
| HY10W-12 | 12 | 10.2 | 41 | 36 | 32 | 250-400 | 100 |
| HY10W-15 | 15 | 12.7 | 51 | 45 | 40 | 250-400 | 100 |
| HY10W-18 | 18 | 15.3 | 62 | 54 | 48 | 250-400 | 100 |
| HY10W-21 | 21 | 17.0 | 72 | 63 | 56 | 250-400 | 100 |
| HY10W-24 | 24 | 19.5 | 82 | 72 | 64 | 250-400 | 100 |
| HY10W-27 | 27 | 22.0 | 93 | 81 | 72 | 250-400 | 100 |
| HY10W-30 | 30 | 24.4 | 103 | 90 | 81 | 250-400 | 100 |
| HY10W-33 | 33 | 27.5 | 113 | 99 | 89 | 250-400 | 100 |
| HY10W-36 | 36 | 29.0 | 124 | 108 | 97 | 250-400 | 100 |
| HY10W-42 | 42 | 34.1 | 145 | 126 | 113 | 250-400 | 100 |
Used for 10kA Power station/Substation Class 2:
| Type | Rated voltage | Maximun Continuous Operating Voltage |
1/4us Lightning Current impulse |
8/20us Lightning Current impulse |
30/60us Switching Current impulse |
2ms Rectangular current impulse withstand |
4/10us High current impulse withstand |
| kV | kV | kV(peak) | kV(peak) | kV(peak) | A | kV(crest) | |
| HY10W-60 | 60 | 48 | 208 | 180 | 160 | 600-900 | 100 |
| HY10W-66 | 66 | 52.8 | 230 | 198 | 172 | 600-900 | 100 |
| HY10W-72 | 72 | 57.6 | 252 | 216 | 184 | 600-900 | 100 |
| HY10W-78 | 78 | 62.4 | 274 | 234 | 196 | 600-900 | 100 |
| HY10W-84 | 84 | 67.2 | 296 | 252 | 208 | 600-900 | 100 |
| HY10W-90 | 90 | 72 | 318 | 270 | 220 | 600-900 | 100 |
| HY10W-96 | 96 | 76.8 | 340 | 288 | 232 | 600-900 | 100 |
| HY10W-102 | 102 | 81.6 | 362 | 306 | 244 | 600-900 | 100 |
| HY10W-108 | 108 | 86.4 | 384 | 324 | 256 | 600-900 | 100 |
| HY10W-120 | 120 | 96 | 428 | 360 | 280 | 600-900 | 100 |
| HY10W-150 | 150 | 120 | 538 | 450 | 340 | 600-900 | 100 |
| HY10W-200 | 200 | 160 | 720 | 600 | 440 | 600-900 | 100 |
/* May 10, 2024 16:49:51 */
!function(){function d(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular laurenceelectirc Products
Mini European Style Crimping Plier Pipe Crimping Tool/Hsc8 6-6
Dtl-1 Series Electric Bimetallic Lug
Nek, Nxl (NEL, NK) Insulation Strain Clamp (wedge type)
Prw-11 Drop-out Fuse Cutout; Power Tool
Fn12-12 Series Indoor Use High Voltage Load Switch
Popular Lightning Protection Products
Electrical Component Light Diverter Lightning Protection with Cap
Silicon Rubber (Porcelain) Housed Metal Oxide Surge Arrester Kema Report
Polymeric Housing Metal Oxide Surge Arrester for Low Voltage System
Zinc Oxide Arrester/Substation Surge Arrester/Hangzhou Professional Manufacture
Lightning Protection Products Silicone Arrester with Kema Type Test Report
Lower Voltage Arrestor Polymeric Surge Arrestor Polymer Lightning Arresters
Popular Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection Products
Popular Surge Arrester Products
Kema Composite 10kv-33kv Lightning Arrester 10ka
Polymer Housed Metal Oxide Surge Arrester Without Gaps
Polymeric Housed Metal-Oxide 11kv Surge Arrester
High Voltage Power Transmission Lightning Arrester
High Voltage Substation Lightning Arresters
Tags: laurenceelectirc, Lightning Protection, Metal-Oxide Composite Lightning Surge Arrester Zinc Oxide Protection, Surge Arrester