Miniature Circuit Breaker MCB MCCB

BM1

ISO9001-2000

Conventional Circuit Breaker

Circuit Breaker

3

MCCB

Fixed

Air

Normal Type Circuit Breaker

Manual Type

Low Voltage Circuit Breakers

85362000

Product Details

 MCCB, RCCB, ELCB

Rated current
 
63A,100A,125A,160A,200A, 300A,400A,630A and 800A
 
No. of poles per phase
 
1
 
Rated service short circuit breaking capacity(kA)
 
Min. 18kA
 

 

MCB, MCCB, RCCB, and ELCB are circuit breakers but all of them are designed for serving a specific purpose. Before knowing about the difference among all, let’s get to know about them a little bit.

MCB

MCB stands for Miniature Circuit Breaker. It automatically switches OFF electrical circuit during any abnormal condition in the electrical network such as overload & short circuitconditions. However, fuse may sense these conditions but it has to be replaced though MCB can be reset. The MCB is an electromechanical device which guards the electric wires &electrical load from overcurrent so as to avoid any kind of fire or electrical hazards. Handling MCB is quite safer and it quickly restores the supply.When it comes to house applications, MCB is the most preferred choice for overload and short circuit protection. MCB can be reset very fast & don’t have any maintenance cost. MCB works on bi-metal respective principle which provides protection against overload current&solenoidshort circuit current.

MCCB

MCCB stands for Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits. It can be used for higher current rating and fault level even in domestic applications. The wide current ratings and high breaking capacity in MCCB find their use in industrial applications. MCCB can be used for protection of capacitor bank, generator protection and main electric feeder distribution. It offers adequate protection whenever an application requires discrimination, adjustable overload setting or earth fault protection.

Difference between MCB and MCCB

S.No MCB MCCB
1 It stands for Miniature Circuit Breaker. It stands for Molded Case Circuit Breaker.
2 Rated current not more than 125 Ampere. Rated Current up to 1600A
3 Its interrupting current rating is under 10KA Their interrupting current ranges from around 10KA -85KA
4 Judging from their power capacities, MCB is mainly used for low Breaking capacity requirement mainly domestic. MCCB is mainly used for both low and high Breaking capacity requirements mainly industrial.
5 Its trip characteristics are normally not adjustable since they basically cater to low circuits. Its trip current may be fixed as well as adjustable for overload and magnetic setting.

 

RCCB

RCCB stands for Residual Current Circuit Breaker. This residual current device is basically an electrical wiring device that disconnects the circuit whenever there is leakage of current flow through the Human body or the current is not balanced between the phaseconductor. It is the safest device to detect and trip against electrical leakage currents, thus ensure protection against electric shock caused by direct contacts. RCCB is generally used in series with an MCB which protects them from over current and short circuit current. Both phase and neutral wires are connected through a RCCB device. These are an extremely effective form of shock protection&widely used for protection from a leakage current of 30,100 & 300mA. It is essential lifesaving equipment used to protect the human body from electrical and is mandatory in many states for domestic installation.

ELCB

ELCB stands for Earth Leakage Circuit Breaker. They have the same function as RCCB but are voltage sensor devise. However, this is an old technology & is not in common use. RCCB being a current sensitive device have a better advantage over ELCB as under:

Difference between RCCB and ELCB

S.No RCCB ELCB
1. RCCB refers to ear stands for Residual Current Circuit Breaker. ELCB stands for Electric Leakage Circuit Breaker.
2. It is a new name and refers to current operated devices. ELCB refers to voltage operated earth leakage device.
3 It ensures 100% detection of leakage current& is available to sense the AC as well as DC leakage current. It is not preferable as it can only detect current that flow back through the main earth wire.
4 RCCB has no connection with the earth wire and that’s why it can trip when both currents (phase and neutral) are different and it withstands up to both the currents are same. ELCB is working based on Earth leakage current. These devices measured the voltage on the earth conductor; if this voltage was not zero this indicated a current leakage to earth.

We are China Miniature Circuit Breaker MCB MCCB manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Circuit Breaker Products

Outdoor Sf6 Gas Circuit Breaker (66kV/132kV)

Tubular Bus-Bar Flexible Fittings Type Mgsd

Support Type Tubular Bus-Bar Flexible Fittings Type Mgsz

Gw16 Hangzhou Outdoor Substation Semi Pantograph Vertical Operation Disconnector

33kv Polymeric Lightning Arresters/Surge Arrester

Tubular Bus-Bar Supports Type Mgg2

Popular jgtrade1 Products

_DSC3518

LED Lighting

15kv Expulsion Fuse Element

Dead End/Anchoring Clamp25-70sqmm

Lug, 2 Hole - 350mcm

Fuse Cutout, Drop out Fuses 36kv 200A

Popular Miniature Circuit Breaker Products

Zw32-12 Outdoor Use High Voltage Vacuum Circuit Breaker

Circuit Breaker with 660V Rated Insulating Voltage

Zn 28-12 Series Vacuum Circuit Breaker

Universal Clamp on Safety Plastic Lockout Devices MCCB Lock

Fuse 60 AMPS- T

Post Insulator High Voltage Electrical Apparatus

Popular Products

Polymeric Lightning Surge Metal-Oxide Arrester

Tubular Bus-Bar Supports Type Mgg2

Adjustable Damping Rings Type Mgh/T

Mv Fuse Unit 415V 660V 400A 80ka

Indoor High Voltage Isolation Switch

Supplies Electrical Equipment High Voltage 15kv 24kv Fuse Cut out

Tags: , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION