Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables
Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables image
Get Latest Price Request a quote
Quick Details
Product Details
Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables
MV Aerial Bundled Conductor ABC Cables Standards:
IEC 60502 / AS/NZS 3599-1 standards
MV Aerial Bundled Conductor ABC Cables Constructions:
Conductor: Round, Aluminium Conductor
Conductor Screen: Extruded semi-conductive layer.
Insulation: XLPE
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Messager wire: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel
wires in a right hand lay.
MV Aerial Bundled Conductor ABC Cables Application:
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders
to residential premises.
The Function of messenger wire:
A) It acts as load bearing wire. B) It acts as earth or neutral conductor
MV Aerial Bundled Conductor ABC Cables Specifications:
AS/NZS 3599 Part 1 6.35/11 kV AL/XLPE /CWS/HDPE Screened Cables
Application
The cables are designed for aerial power lines with rated voltage Uo(Um) 10(12) kV ~35(40.5)kV.
Product properties and range
* Rated voltage is 10kV and 35KV
* No. of cores : 1 , Nominal cross-section(mm2): 16~300
* Max.Continuous permissive working temperature of conductor:
XLPE insulation should be not more than 90ºC.
*Max. Temperature at short circuit (the longest continuous time is not more than 5S) XLPE insulation is 250ºC.
* Installation temperature of cable should be not less than -20ºC.
* Permissive bending radius of cable should be not less than 20(D+d) mm.
D -the actual overall diameter of cable ,mm;
d-the actual overall diameter of conductor ,mm.
* Insulation resistance of common insulation construction of aerial cable should be not less than 1500MΩ km, and insulation
resistance of thin XLPE insulated construction of light aerial cable should be not less than 1000mΩ km.
parameter of abc cable
| Number of CoresxNominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 30ºCambient temp | ||||
| Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
| No.×mm2 | mm | mm | mm | mm | No.×mm | mm2 | KN |
| 3×35 | 6.9 | 3.4 | 0.8 | 1.2 | 7/4.75 | 52.4 | 1370 |
| 3×50 | 8.1 | 3.4 | 0.8 | 1.2 | 7/4.75 | 54.6 | 1530 |
| 3×70 | 9.7 | 3.4 | 0.8 | 1.2 | 7/4.75 | 57.8 | 1790 |
| 3×95 | 11.4 | 3.4 | 0.8 | 1.2 | 7/4.75 | 61.3 | 2100 |
| 3×120 | 12.8 | 3.4 | 0.8 | 1.2 | 19/3.50 | 67.3 | 2540 |
| 3×150 | 14.2 | 3.4 | 0.8 | 1.2 | 19/3.50 | 70.1 | 2840 |
| 3×185 | 15.7 | 3.4 | 0.8 | 1.2 | 19/3.50 | 73.1 | 3190 |
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /HDPE Non-screened Cables
| Number of CoresxNominal Cross Section | Diameter of Conductor | Thickness of Insulation | Thickness of Insulation Screen | Thickness of Sheath | Messenger Suspension Unit Stranding | Nominal Sectional Area | Breaking Load |
| No.×mm2 | mm | mm | mm | mm | No.×mm | mm2 | KN |
| 3×35 | 6.9 | 5.5 | 0.8 | 1.2 | 7/4.75 | 61 | 1780 |
| 3×50 | 8.1 | 5.5 | 0.8 | 1.2 | 7/4.75 | 63.3 | 1970 |
| 3×70 | 9.7 | 5.5 | 0.8 | 1.2 | 7/4.75 | 66.5 | 2260 |
| 3×95 | 11.4 | 5.5 | 0.8 | 1.2 | 7/4.75 | 69.9 | 2600 |
| 3×120 | 12.8 | 5.5 | 0.8 | 1.2 | 19/3.50 | 75.9 | 3070 |
| 3×150 | 14.2 | 5.5 | 0.8 | 1.2 | 19/3.50 | 78.7 | 3390 |
| 3×185 | 15.7 | 5.5 | 0.8 | 1.2 | 19/3.50 | 81.7 | 3760 |
AS/NZS 3599 Part 1 12.7/22 kV AL/XLPE /CWS/HDPE Screened Cables
| Number of CoresxNominal Cross Section | Diameter of Conductor | Thickness of Insulation | Thickness of Insulation Screen | Copper Wire Screen Stranding | Thickness of Sheath | Galvanized Steel Wire Stranding | Nominal Sectional Area | Breaking Load |
| No.×mm2 | mm | mm | mm | No.×mm | mm | No.×mm | mm2 | KN |
| No.×mm2 | mm | mm | mm | No.×mm | mm | No.×mm | mm2 | KN |
| Light Duty Screen | ||||||||
| 3×35 | 6.9 | 5.5 | 0.8 | 25/0.85 | 1.8 | 7/2.00 | 62.7 | 2280 |
| 3×35 | 6.9 | 5.5 | 0.8 | 25/0.85 | 1.8 | 19/2.00 | 66.7 | 2580 |
| 3×50 | 8.1 | 5.5 | 0.8 | 25/0.85 | 1.8 | 19/2.00 | 69 | 2780 |
| 3×70 | 9.7 | 5.5 | 0.8 | 25/0.85 | 1.9 | 19/2.00 | 72.6 | 3110 |
| 3×95 | 11.4 | 5.5 | 0.8 | 25/0.85 | 1.9 | 19/2.00 | 76 | 3460 |
| 3×120 | 12.8 | 5.5 | 0.8 | 25/0.85 | 2 | 19/2.00 | 79.2 | 3810 |
| 3×150 | 14.2 | 5.5 | 1 | 25/0.85 | 2 | 19/2.00 | 82.8 | 4230 |
| 3×185 | 15.7 | 5.5 | 1 | 25/0.85 | 2.1 | 19/2.00 | 86.2 | 4650 |
| Heavy Duty Screen | ||||||||
| 3×35 | 6.9 | 5.5 | 0.8 | 40/0.85 | 1.8 | 7/2.00 | 62.7 | 2510 |
| 3×35 | 6.9 | 5.5 | 0.8 | 40/0.85 | 1.8 | 19/2.00 | 66.7 | 2810 |
| 3×50 | 8.1 | 5.5 | 0.8 | 23/1.35 | 1.8 | 19/2.00 | 71 | 3300 |
| 3×70 | 9.7 | 5.5 | 0.8 | 32/1.35 | 1.9 | 19/2.00 | 74.6 | 3970 |
| 3×95 | 11.4 | 5.5 | 0.8 | 39/1.35 | 1.9 | 19/2.00 | 78 | 4600 |
| 3×120 | 12.8 | 5.5 | 0.8 | 39/1.35 | 2 | 19/2.00 | 81.2 | 4950 |
| 3×150 | 14.2 | 5.5 | 1 | 39/1.35 | 2 | 19/2.00 | 84.8 | 5360 |
| 3×185 | 15.7 | 5.5 | 1 | 39/1.35 | 2.1 | 19/2.00 | 88.2 | 5790 |
Other cross-sections can be offered upon request.
IEC 60502 6.35/11 kV ABC for Overhead Distribution Lines
| Number of CoresxNominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 30 ambient temp | ||||
| Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
| No.×mm2 | No.×mm | mm2 | Ω/Km | No.×mm | mm2 | KN | A |
| 3X50 + 1X25 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 116 |
| 3X70 + 1X50 | 19/.14 | 70 | 0.443 | 7/3.15 | 50 | 62 | 210 |
| 3X95+ 1X50 | 19/2.52 | 95 | 0.32 | 7/3.0 | 50 | 60 | 173 |
| 3X185+1X120 | 37/2.52 | 185 | 0.164 | 7/4.67 | 120 | 150 | 259 |
| 3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 365 |
| 3X240 +1X50 | 61/2.25 | 240 | 0.125 | 7/3.15 | 50 | 62 | 500 |
IEC 60502 19/33 kV ABC for Overhead Distribution Lines
| Number of CoresxNominal Cross Section | Phase Conductor | Messenger Suspension Unit | Continuous current rating at 30 ambient temp | ||||
| Stranding | Nominal Sectional Area | Maximum Conductor Resistance | Stranding | Nominal Sectional Area | Breaking Load | ||
| No.×mm2 | No.×mm | mm2 | Ω/Km | No.×mm | mm2 | KN | A |
| 3X50 + 1X50 | 19/1.78 | 50 | 0.641 | 7/3.0 | 50 | 60 | 165 |
| 3X150+ 1X50 | 37/2.25 | 150 | 0.206 | 7/3.0 | 50 | 60 | 315 |
| 3X185+1X70 | 37/2.52 | 185 | 0.164 | 7/3.57 | 70 | 91 | 355 |
| 3X70 +1X50 | 19/2.14 | 7 | 0.443 | 7/3.15 | 50 | 62 | 250 |
| 3X150 +1X50 | 37/2.25 | 150 | 0.206 | 7/3.15 | 50 | 62 | 370 |
Factroy and Products
We are China Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Conductor ABC Cable Products
Aerial Bundeld Cable 4core 95mm2 for Myanmar Market
2*6AWG+1*6AWG AAC Conductor Plum ABC Aerial Bundle Overhead Cable
Duplex/Triplex/Quadruplex Service Drop XLPE Insulated ABC Aerial Bundle Cable
Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables
Overhead Insulated ABC Cable with Messenger Bare AAAC Conductor
Popular Aerial Bundled Conductor Products
Aerial Bundled Conductor XLPE Insulated/PE Insulation Aluminum Overhead Cable
Aerial Bundled Conductor Cable ABC Aerial Cable Twister Insulated High Quality
Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables
0.6/1kv Aluminium Strand Conductor Overhead Aerial Bundle Cable
Competitive Price of Aerial Bundled Cable ABC Cable
Aerial Bundled Conductor SIP1 SIP2 SIP3 SIP4 Cable ABC Cable
Popular IEC ABC Cable Products
Mv Distribution Line Aerial Bundled Conductor ABC Overhead Cables
Excellent Performance IEC Standard ABC Cable
High Quality ABC Cable with IEC Standard
Popular jytopcable Products
Areal Bundled Conductors Service Drop Overhead Cable
Nyby Copper PVC Insulation Steel Tape Armored PVC Sheath Cable
Bare Conductor AAC 120mm2 for DIN 48201
Low Voltage Armoured Cable Nyby Nayby N2xby Na2xby
Copper Conductor XLPE Insulated Power Cable for High Voltage 21/35kv
0.6/1kv Type Mv PVC/Swa/PVC 2.5mm 4 Core Copper Power Cable with Armored
Tags: AAC Conductor ABC Cable, Aerial Bundled Conductor, IEC ABC Cable, jytopcable