Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE)

China 
                        Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE)
                      manufacture and supplier

Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE) image

Get Latest Price Request a quote

Quick Details

Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE)

ABC CABLE

Yifang

ABC

ISO, CCC

H68 Aluminium

Round Wire

No

XLPE

DC & AC

Low and Medium Voltage Cable

Overhead, Power Station

AS/NZS 3599.1

yifang

Wooden Drum

16mm2 to 150mm2

China

8544609000

Product Details

 

6.35/11kV & 12.7/22kV Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1(AL/XLPE/HDPE)

Application

Three XLPE insulated cores are bundled around the AAAC/1120 support conductor in a right hand lay.

Standard

AS/NZS 3599.1

Construction

Phase Conductor Circular compacted stranded H68 aluminium to BS2627.
Conductor Screen Extruded semi-conductive layer.
Insulation XLPE.
Insulation Screen Extruded semi-conductive layer.
Outer Sheath HDPE.
Support Conductor Aluminium alloy conductor (AAAC/1120).
Assembly Three XLPE insulated cores are bundled around the AAAC/1120 support conductor in a right hand lay.

Dimensions

number of cores x nominal cross section Nominal conductor diameter Nominal insulation thickness Nominal insulation screen thickness Nominal sheath thickness AAAC/1120 support conductor size Nominal overall diameter Weight Continuous current rating, A
Still air 1m/s wind 2m/s wind
mm^2 mm mm mm mm No/mm mm kg/km A A A
6.35/11kV
3×35 6.9 3.4 0.8 1.2 7/4.75 52.4 1370 110 155 185
3×50 8.1 3.4 0.8 1.2 7/4.75 54.6 1530 130 185 225
3×70 9.7 3.4 0.8 1.2 7/4.75 57.8 1790 160 235 280
3×95 11.4 3.4 0.8 1.2 7/4.75 61.3 2100 195 285 345
3×120 12.8 3.4 0.8 1.2 19/3.50 67.3 2540 230 335 405
3×150 14.2 3.4 0.8 1.2 19/3.50 70.1 2840 255 380 460
3×185 15.7 3.4 0.8 1.2 19/3.50 73.1 3190 295 440 530
12.7/22kV
3×35 6.9 5.5 0.8 1.2 7/4.75 61.0 1780 110 155 180
3×50 8.1 5.5 0.8 1.2 7/4.75 63.3 1970 130 185 220
3×70 9.7 5.5 0.8 1.2 7/4.75 66.5 2260 160 230 275
3×95 11.4 5.5 0.8 1.2 7/4.75 69.9 2600 195 285 335
3×120 12.8 5.5 0.8 1.2 19/3.50 75.9 3070 225 330 395
3×150 14.2 5.5 0.8 1.2 19/3.50 78.7 3390 255 375 450
3×185 15.7 5.5 0.8 1.2 19/3.50 81.7 3760 290 435 520

We are China Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

25mm2/50mm2 ABC Power Cable

ABC Cable 0.6/1 Kv, 4c X 70 mm2, Al/XLPE for Overhead

0.6/1kv ABC Cable PE/XLPE Insulation

Aerial Insulated Cable with Rated Voltage 0.6 / 1kv, 10kv or 35kv (aerial branched cable)

0.6/1kv 6AWG Duplex XLPE Insulated ABC Cable

25mm2 XLPE/PE Insulation Overhead Cable Aerial Bundled Cable

Popular Aerial Bundled Cables Products

600/1000V ABC Aerial Bundled Cables to IEC 60502 & Tnb Specification (AL/PE)

Low Voltage LV Aerial Bundled Cables Triplex Cable ABC Cable Overhead Cable

600/1000V ABC Aerial Bundled Cables to NFC 33-209 (AL/XLPE)

600/1000V ABC Aerial Bundled Cables to AS/NZS 3560.1 (AL/XLPE)

Sample Customization Tnb Specification IEC 60502 600/1000V ABC Aerial Bundled Cables Aluminum Conductor Aerial Bunched Cable

NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines

Popular Cables to AS/NZS 3599.1 (AL/XLPE) Products

  • No related articles
  • Popular yifangcable Products

    ABC XLPE Cable 4core 35sqmm

    Bare AAC / AAAC / ACSR Conductor

    2.5mm2 PVC Insulated Copper House Building Wire - Household Wire

    Rhh/Rhw-2 Single Al Conductor 2000V Power Cable

    Bare ACSR Dog BS 215 Standard

    0.6/1kv, Flame Retardant Power Cable (ZR-VV22)

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION