Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE)
Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE) image
Get Latest Price Request a quote
Quick Details
Product Details
6.35/11kV & 12.7/22kV Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1(AL/XLPE/HDPE)
Application
Three XLPE insulated cores are bundled around the AAAC/1120 support conductor in a right hand lay.
Standard
AS/NZS 3599.1
Construction
Phase Conductor | Circular compacted stranded H68 aluminium to BS2627. |
---|---|
Conductor Screen | Extruded semi-conductive layer. |
Insulation | XLPE. |
Insulation Screen | Extruded semi-conductive layer. |
Outer Sheath | HDPE. |
Support Conductor | Aluminium alloy conductor (AAAC/1120). |
Assembly | Three XLPE insulated cores are bundled around the AAAC/1120 support conductor in a right hand lay. |
Dimensions
number of cores x nominal cross section | Nominal conductor diameter | Nominal insulation thickness | Nominal insulation screen thickness | Nominal sheath thickness | AAAC/1120 support conductor size | Nominal overall diameter | Weight | Continuous current rating, A | ||
---|---|---|---|---|---|---|---|---|---|---|
Still air | 1m/s wind | 2m/s wind | ||||||||
mm^2 | mm | mm | mm | mm | No/mm | mm | kg/km | A | A | A |
6.35/11kV | ||||||||||
3×35 | 6.9 | 3.4 | 0.8 | 1.2 | 7/4.75 | 52.4 | 1370 | 110 | 155 | 185 |
3×50 | 8.1 | 3.4 | 0.8 | 1.2 | 7/4.75 | 54.6 | 1530 | 130 | 185 | 225 |
3×70 | 9.7 | 3.4 | 0.8 | 1.2 | 7/4.75 | 57.8 | 1790 | 160 | 235 | 280 |
3×95 | 11.4 | 3.4 | 0.8 | 1.2 | 7/4.75 | 61.3 | 2100 | 195 | 285 | 345 |
3×120 | 12.8 | 3.4 | 0.8 | 1.2 | 19/3.50 | 67.3 | 2540 | 230 | 335 | 405 |
3×150 | 14.2 | 3.4 | 0.8 | 1.2 | 19/3.50 | 70.1 | 2840 | 255 | 380 | 460 |
3×185 | 15.7 | 3.4 | 0.8 | 1.2 | 19/3.50 | 73.1 | 3190 | 295 | 440 | 530 |
12.7/22kV | ||||||||||
3×35 | 6.9 | 5.5 | 0.8 | 1.2 | 7/4.75 | 61.0 | 1780 | 110 | 155 | 180 |
3×50 | 8.1 | 5.5 | 0.8 | 1.2 | 7/4.75 | 63.3 | 1970 | 130 | 185 | 220 |
3×70 | 9.7 | 5.5 | 0.8 | 1.2 | 7/4.75 | 66.5 | 2260 | 160 | 230 | 275 |
3×95 | 11.4 | 5.5 | 0.8 | 1.2 | 7/4.75 | 69.9 | 2600 | 195 | 285 | 335 |
3×120 | 12.8 | 5.5 | 0.8 | 1.2 | 19/3.50 | 75.9 | 3070 | 225 | 330 | 395 |
3×150 | 14.2 | 5.5 | 0.8 | 1.2 | 19/3.50 | 78.7 | 3390 | 255 | 375 | 450 |
3×185 | 15.7 | 5.5 | 0.8 | 1.2 | 19/3.50 | 81.7 | 3760 | 290 | 435 | 520 |
We are China Mv Non Screened ABC Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE/HDPE) manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
ABC Cable 0.6/1 Kv, 4c X 70 mm2, Al/XLPE for Overhead
0.6/1kv ABC Cable PE/XLPE Insulation
Aerial Insulated Cable with Rated Voltage 0.6 / 1kv, 10kv or 35kv (aerial branched cable)
0.6/1kv 6AWG Duplex XLPE Insulated ABC Cable
25mm2 XLPE/PE Insulation Overhead Cable Aerial Bundled Cable
Popular Aerial Bundled Cables Products
600/1000V ABC Aerial Bundled Cables to IEC 60502 & Tnb Specification (AL/PE)
Low Voltage LV Aerial Bundled Cables Triplex Cable ABC Cable Overhead Cable
600/1000V ABC Aerial Bundled Cables to NFC 33-209 (AL/XLPE)
600/1000V ABC Aerial Bundled Cables to AS/NZS 3560.1 (AL/XLPE)
NFC 33-209 ABC Aerial Bundled Cables for Overhead Power Lines
Popular Cables to AS/NZS 3599.1 (AL/XLPE) Products
Popular yifangcable Products
Bare AAC / AAAC / ACSR Conductor
2.5mm2 PVC Insulated Copper House Building Wire - Household Wire
Rhh/Rhw-2 Single Al Conductor 2000V Power Cable
0.6/1kv, Flame Retardant Power Cable (ZR-VV22)
Tags: ABC Cable, Aerial Bundled Cables, Cables to AS/NZS 3599.1 (AL/XLPE), yifangcable