MV Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable

China 
                        MV Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable
                      manufacture and supplier

MV Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable image

Get Latest Price Request a quote

Quick Details

MV Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable

MV Power Cable

Yifang

N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey

ISO, CCC, CE, Kema

Copper or Aluminum

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

Red , Black , Other as Per Requirement

According to Requirements

According to Requirements

IEC 60502

Copper Wire+Copper Tape

Black PVC

Yifang Cable

Wooden Drum/Iron Wooden Drum/Steel Drum

25-1000mm2

Zhengzhou, Henan, China

8544601200

Product Details

 MV Power Cable N2XY, NA2XY, N2XS2Y, NA2XS2Y, N2XSEY Cable

Applications

Used for Power transmission and distribution line with voltage rated at 35kv and below. 

For Layling indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Standards 

 

Description 

CU/XLPE/STA/PVC, IEC 60502

IEC 60502, IEC 60228, GB/T 12706.1-2008.

CE, CCC, KEMA

 

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: PVC

Armour: Galvanized Steel Wire or tape 

Sheath: PVC type ST2 to IEC 60502, black

Note: Insulation color as per standards or customer requirement

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen

Semi-conductor (MV only)

Metalic Shield

Copper Tape Screen or Copper wire & copper tape Shield (MV must, LV optional)

Filler

PP fillers

Wrapping Tape

Non woven wrapping tape or lsoh wrapping tape

Inner Covering

Extruded PVC, or LSOH (MV only)

Armour

 Galvanized Steel wire/ Galvanized steel tape/Aluminum wire/ Aluminum Tape armour

Overall Sheath

PVC, FR-PVC, MDPE,HDPE

Technical data

Rated voltage: 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV

Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (160°C when section-area below 300mm2, 140°C when section-area above 300mm2)

Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C

Min. Bending Radius: single core cable 20(d+D)±5%

                   Multi-core cable 15(d+D)±5%

 

MV(6 to 35kv) Power Cable
Model and Description No.of Core Conductor cross-section area(mm2)
xlpe insulation 1       3  10 16 25 35 70 95 120 150 185 240 300 400 500 630 800 1000
Cu core Al Core
YJV;PVC sheathed power cable YJLV;PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu Core Al Core
VV(VY);PVC(PE)sheathed power cable VLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable

 

Certificates

CE, RoHS, CCC, KEMA and more others at request

International: IEC 60502, IEC 60228

China: GB/T 12706.1-2008

 

Other standards such as BS,DIN and ICEA upon request 

 

4 Table of the voltage, cores and cross-section

Item

Category    A ,B

3.6/6kV

6/10kV

8.7/15kV

12/20kV

18/30kV

21/35kV

Category    A ,B

6/6kV

8.7/10kV

12/15kV

18/20kV

        –

26/35kV

Single core

           mm2

25-1200

25-1200

35-1200

50-1200

50-1200

50-1200

Three core

           mm2

25-400

25-400

35-400

50-400

50-400

50-400

 

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

 

We are China MV Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 35kv Mv Cable Products

N2XY MV Power Cable

N2xy Mv Power Cable

Mv Power Cable N2xy, Na2xy, N2xs2y, Na2xs2y, N2xsey Cable

Popular Mv Cable Products

N2xy Mv Power Cable

1X400 3X1X240 Sqmm XLPE Insulated Aluminum 12/20 KV 24 KV Underground Cable

22kv Al/Cu Copper Aluminum Conductor XLPE/PVC Insulated Steel Wire/Tape Armoured Single Core 630mm2 Power Underground Cable

Medium Voltage 3 Core 11kv 15kv 33kv Underground XLPE Cable

6.35/11kv Underground Single Core Copper Armored Electric Cable 300mm2

6.35/11kv Underground Single Core Copper Armored Electric Cable 400mm2

Popular N2xy Cable Products

150mm2 Underground Power Cables Copper Conductor 4 Core Cables Nyy N2xy

Cu Conductor XLPE Insulated Power Cable 4 Core IEC60502 BS7870 Standard

Copper Conductor XLPE Insulated Power Cable Multi Core Heavy Load

N2xy N2xsey Na2xy Na2xsey XLPE Insulated PVC Sheath Power Cable

Waterproof XLPE Insulated Power Cable Low Voltage Compact Stranded Copper Conductor

XLPE Insulated Armoured Control Cable Multi Core Flame Retardant N2xy

Popular yifangcable Products

IEC60227 PVC Insulated Electric Wire/Building Wire

7/12" Stay Wire 7/2.64mm BS183

600/1000V XLPE Cable 300mm Single Core

CE Certificate 0.6/1kv PVC Cable LV Nyy Nyby Nyry Nycy Naycy Nycwy Copper Power Cable

Aluminum Conductor XLPE Insulation Double Steel Tape Armour PVC U1000 Arvfv Cable

11kv 95sqmm 3 Core Copper or Alu Power Cables

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION