N2X-Oh Cable 3*120 3*240 Copper Building Cable

China 
                        N2X-Oh Cable 3*120 3*240 Copper Building Cable
                      manufacture and supplier

N2X-Oh Cable 3*120 3*240 Copper Building Cable image

Get Latest Price Request a quote

Quick Details

N2X-Oh Cable 3*120 3*240 Copper Building Cable

N2X-OH

OEM

YJV

ISO, CCC

Bare Copper Wire

Round Wire

PVC

XLPE

AC Cable

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station, Telecommunication

OEM

in Drum or in Coil

4**10

Henan

8544492100

Product Details

Al/CU Conductor XLPE/PVC Insulated Thin/Thick steel armored PE Sheathed Power Cable.
Relative manufacturing standards: IEC60505, BS, DIN,ASTM,JIS or other standards.
 
Application: 
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
 
Using features: 
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV and 0.6/1kV.
2. No. Of core: Single-core, Two-core,Three-core,Four-core,Five-core,Six-core.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC. 
4. D. C. Resistance of the conductor complies with the stipulations of international standar. 
5. The environment temperature should be no lower than zero degree when lay. Otherwise it should be preheated. 
6. The cable is laid without horizontal drop limit. The Min. Bending radius of cables should be no smaller than 12 times of cable outer diameter. 
7. Working Frequency Voltage Test: 
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture. 
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture. 
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture. 
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable
 
This series includes:
Copper (aluminum) conductor, XLPE/PVC insulated ,PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA) PVC sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel tape armoring(DSTA), PE sheathed power cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PVC sheathed power Cables 
Copper (aluminum) conductor, XLPE/PVC insulated, steel wire armoring(SWA), PE sheathed power cables

View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Cable
Electric Cable
Control Cable
Wire Cable
Video Cable
Copper Cable
View More 

We are China N2X-Oh Cable 3*120 3*240 Copper Building Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 3*120 Copper Building Cable Products

  • No related articles
  • Popular 3*240 Copper Building Cable Products

  • No related articles
  • Popular N2X-Oh Cable Products

  • No related articles
  • Popular zzhongdacable Products

    3X4mm2 Copper Conductor XLPE Insulated Armored Electrical Cable

    600/1000V IEC 60502-1 Cu/Al Conductor XLPE Insulated Power Cables

    XLPE Insulation Material and Aluminum Conductor Material ABC Cable Price

    Low Voltage Electrical Energy Cable N2xoh 0, 6/1kv 3-1X10, 16mm2

    Flat Cable, Building Wire Twin and Earth PVC Electrical Wire Cable

    Underground Cooper and Aluminum Power Cable 1000V Tj Cable Thw

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION