N2xh-J, N2xh-O, 0.6/1kv Halogen-Free and Flame-Resistant Power Cable
N2xh-J, N2xh-O, 0.6/1kv Halogen-Free and Flame-Resistant Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
N2XH cable Application:
Halogen-free and flame-resistant cable for power transmission and power distribution, generally for fixed installation in public buildings as hospitals, schools, hotels, airports and railway stations, where are high requirements for security. N2XH – Halogen-free power cable acc. HD 604/VDE 0276-604. Building installation cable with improved fire characteristics for fixed installation.
Kabel N2XH Features :
-Flame-retardant according IEC 60332-1-2.
-No flame-propagation according to IEC 60332-3-24
-Halogen-free according to IEC 60754-1
-Low smoke density according to IEC 61034-2
Cable N2XH Construction:
Conductor : Bare copper wire conductor class 1 for cross section 1.5mm2 to 16.0mm2; class 2 for cross section 16mm2 to 95mm2.
Abbreviations "re", "rm", "se", "sm":
r = round conductor form;
s = sectorial conductor form;
e = single-wire conductor;
m = multi-wire conductor;
Insulation : Cross-linked polyethylene type XLPE
Inner covering: halogen-free compound, flame-resistant
Sheath: halogen-free compound, flame-resistant type HM4 according to HD 604
Sheath color : black.
N2XH-J With protective conductor.
N2XH-O without protective conductor.
Technical data:
1) Conductor acc. to HD 604
2) rated voltage Uo/U: 0.6/1 kV
3) test voltage: alternating voltage – 4 kV
4) insulation resistance at 90 °C: min 1012 Ω x cm
5) maximum conductor temperature: + 90 °C
6) max. conductor temperature at short circuit for 5 s : +250 °C
7) temperature of environment: -30 °C to +70 °C
8) minimum temperature during installation: -5 °C
9) minimum bending radius during installation: single core : 15D; multiple core : 12D (D – outer cable diameter)
10) flame test: flame-retardant acc. to IEC 60332-3 category "B" and VDE 0472 part 804
11) corrosivity of combustion gases – in acc. to VDE 0472 part 813
12) low smoke density – in acc. to VDE 0472 part 816.
Number of cores and mm² per conductor | Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) |
N2XH-J | |||
1×1,5 RE | 6.0 | 14.0 | 53 |
1×2,5 RE | 6,5 | 24.0 | 90 |
1×4 RE | 8,5 | 38.0 | 69 |
1×6 RE | 6,5 | 58.0 | 90 |
1×10 RE | 7,3 | 96.0 | 131 |
1×16 RM | 8,6 | 154.0 | 197 |
1×25 RM | 10,2 | 240.0 | 293 |
1×35 RM | 11,3 | 336.0 | 389 |
1×50 RM | 12,7 | 480.0 | 517 |
1×70 RM | 14,6 | 672.0 | 717 |
1×95 RM | 16,3 | 912.0 | 972 |
1×120 RM | 18,3 | 1152.0 | 1215 |
1×150 RM | 20.0 | 1440.0 | 1494 |
1×185 RM | 22,6 | 1776.0 | 1855 |
1×240 RM | 25,2 | 2304.0 | 2387 |
1×300 RM | 27,9 | 2880.0 | 2971 |
2×1,5 RE | 12.0 | 29.0 | 185 |
2×2,5 RE | 13.0 | 48.0 | 220 |
2×4 RE | 14.0 | 77.0 | 275 |
2×6 RE | 15.0 | 115.0 | 335 |
2×10 RE | 16.0 | 192.0 | 450 |
2×16 RM | 18.0 | 307.0 | 625 |
2×25 RM | 21.0 | 480.0 | 950 |
3×1,5 RM | 13.0 | 43.0 | 179 |
3×2,5 RM | 14.0 | 72.0 | 225 |
N2XH-O | |||
1×25 RM | 10,2 | 240.0 | 293 |
1×35 RM | 11,3 | 336.0 | 389 |
1×50 RM | 12,7 | 480.0 | 517 |
1×70 RM | 14,6 | 672.0 | 717 |
1×95 RM | 16,3 | 912.0 | 972 |
1×120 RM | 18,3 | 1152.0 | 1215 |
1×150 RM | 20.0 | 1440.0 | 1494 |
1×185 RM | 22,6 | 1776.0 | 1855 |
1×240 RM | 25,2 | 2304.0 | 2387 |
1×300 RM | 27,9 | 2880.0 | 2971 |
3×1,5 RE | 8,9 | 43.0 | 125 |
3×2,5 RE | 9,8 | 72.0 | 163 |
3×4 RE | 10,8 | 115.0 | 219 |
3×6 RE | 11,8 | 173.0 | 289 |
3×10 RE | 13,6 | 288.0 | 431 |
3×16 RM | 16,7 | 461.0 | 638 |
3×25 RM | 20,2 | 720.0 | 1015 |
3×35 RM | 22,3 | 1231 | |
3×50 RM | 25,5 | 1440.0 | 1652 |
3×70 RM | 30.0 | 2016.0 | 2455 |
3×95 RM | 32.0 | 2736.0 | 3260 |
3×120 RM | 35.0 | 3456.0 | 4000 |
3×150 RM | 39.0 | 4320.0 | 5100 |
3×185 RM | 44.0 | 5328.0 | 6160 |
3×240 RM | 49.0 | 6912.0 | 8000 |
4×1,5 RE | 9,7 | 58.0 | 147 |
4×2,5 RE | 10,6 | 96.0 | 195 |
4×4 RE | 11,7 | 154.0 | 266 |
4×6 RE | 12,9 | 230.0 | 355 |
4×10 RE | 15,2 | 384.0 | 547 |
4×16 RM | 18,3 | 614.0 | 839 |
4×25 RM | 22,6 | 960.0 | 1294 |
4×35 RM | 25,8 | 1344.0 | 1605 |
4×50 RM | 29,4 | 1920.0 | 2154 |
4×70 RM | 34,4 | 2688.0 | 3047 |
4×95 RM | 38,6 | 3648.0 | 4102 |
4×120 RM | 42,4 | 4608.0 | 5062 |
4×150 RM | 47,2 | 5760.0 | 6256 |
4×185 RM | 52.0 | 7104.0 | 7751 |
4×240 RM | 58,6 | 9216.0 | 10047 |
5×1,5 RE | 10,5 | 72.0 | 174 |
5×2,5 RE | 11,5 | 120.0 | 233 |
5×4 RE | 12,7 | 192.0 | 319 |
5×6 RE | 14,2 | 288.0 | 437 |
5×10 RE | 17.0 | 480.0 | 682 |
5×16 RM | 20,2 | 768.0 | 1036 |
5×25 RM | 24,9 | 1200.0 | 1584 |
5×35 RM | 28,4 | 1680.0 | 2155 |
7×1,5 RE | 11,3 | 101.0 | 214 |
7×2,5 RE | 12,4 | 168.0 | 291 |
7×4 RE | 17.0 | 269.0 | 540 |
10×1,5 RE | 14.0 | 144.0 | 299 |
10×2,5 RE | 15,8 | 240.0 | 419 |
12×1,5 RE | 14,7 | 173.0 | 342 |
12×2,5 RE | 16,4 | 288.0 | 480 |
12×4 RE | 21.0 | 461.0 | 805 |
14×1,5 RE | 17.0 | 202.0 | 480 |
14×2,5 RE | 19.0 | 336.0 | 635 |
19×1,5 RE | 18.0 | 274.0 | 600 |
19×2,5 RE | 21.0 | 456.0 | 810 |
24×1,5 RE | 20,2 | 346.0 | 625 |
24×2,5 RE | 24.0 | 576.0 | 990 |
30×1,5 RE | 21,3 | 432.0 | 738 |
30×2,5 RE | 23,7 | 720.0 | 1045 |
3×50/25 SM | 28,5 | 1680.0 | 2100 |
3×70/35 SM | 31,4 | 2352.0 | 2800 |
3×95/50 SM | 34,9 | 3216.0 | 3750 |
3×120/70 SM | 38.0 | 4128.0 | 4750 |
3×150/70 SM | 43,3 | 4992.0 | 5750 |
3×185/95 SM | 47,2 | 6240.0 | 7200 |
3×240/120 SM | 53,4 | 8064.0 | 9300 |
We are China N2xh-J, N2xh-O, 0.6/1kv Halogen-Free and Flame-Resistant Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Flame Retardant Cable Products
Flame Retardant Cable (FR-YJV) Copper Conductor
Fr PVC Insulation Copper Wire Cable H07V-R Thhn/Thhw House Wiring 1.5mm 2.5mm 4mm
Low Voltage Cable Yjv22 Yjv23 Yjv33 Yjv32
Aluminum Alloy AC 90 Fire Retardant Cable
Low Smoke Zero Halogen Flame Retardant Cable
25mm2, 35mm2, 50mm2, 95mm2 0.6/1kv Fire-Resisting XLPE Cable
Popular Halogen Free Cable Products
Five-Core XLPE Insulation LSZH Sheath Halogen Free Power Cables
Freetox Halogen-Free N2xoh 0, 6/1 Kv 3X120+1X70 mm2 Multipolar Cable
H052xz1-F Copper Halogen Free Flame Retardant Flexible XLPE Insulation Cable
0.6/1kv N2xh Flame-Retardant Halogen-Free Cable for Public Buildings
Lsfh LSZH Lsoh Fire-Resistant Flame Retardant Mineral Insulated Power Cable
Halogen-Free Fire Performance Cable Nhxh-J Fe180 E90 3X1, 5mm2 3X2.5
Popular jytopcable Products
Hot Dipped Galvanized Steel/Stay/Guy Wire
Low Voltalge Aerial Bundled Cable Quadruplex Cable ABC
AAAC Conductor to ASTM B399 Professional Manufacturer and Supplier
Copper Three Cores PVC Insulated PVC Sheath Electric Power Cable
PVC Insulated Aluminum Cable for Low Voltage