NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line Cable
NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line Cable image
Get Latest Price Request a quote
Basic Info.
Packaging & Delivery
Product Description
LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, Overhead ABC cables, Conductor, AAAC, AAC, power cable etc.
In terms of quality, it is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-sale service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.
Product Description
ASTM BS CSA Standard Overhead Aluminium Conductor Aerial Bundle Cable
ABC Cable Application
This production is suitable for electric cable below 10KV AC, which will be mainly used for city power grid transmission line. It is simple structure,
safety and stable and is of good mechanism physical and electricity function. And also it has good function of proof track, creepage
discharge, and air. Compared with naked wire, it has small gap so that can save wire route and decrease voltage drop. What is the
most important is that it will decrease the accident in power supplying and make people safe.
Specific Property for ABC Cable
1) the min. temperature of laying cable is not lower than 20°C.
2) the Max. temperature of HDPE insulated cable is 150°C, and that of the XLPE insulated cable is 250°C when short circuit (5 seconds ).
3) the Max. long-time working temperature of conductor of the HDPE insulated cable is 75°C,and that of the XLPE insulated cable is 90°C.
4) every fault time of single-phase earth shall be less than one minute. And that also shall be less than 8 hours per time and be less than 125hours every year.
5) the permissible curving radius of single-core cable should be not less than 20(D±d) ±5%mm, and that of the multi-core cable should be not less than 15(D±d) ±5%mm.
ABC cable sketch structure as follows:
Executive Standard:IEC
Phas e | Neutral | Phas e | Neutral |
Approx. Overall Diam eter |
Max. D.C. Res is tance of Conductor at 20ºC |
||||
AAC+UV-XLPE | AAAC | Com pact Conductor | UV-XLPE Ins ulation | Conductor | |||||
No.X Norm al Cr os s Section of Cores |
No.X Norm al Cr os s Section of Cores |
No.of Al.Wire | Overall Dia. | Norm al Thick nes s | Min. | No./Dia. of Al Alloy Wire | Phas e | Neutral | |
No. X m m 2 | No. X m m 2 | – | m m | m m | Min. | No./m m | m m | ohm /k m | ohm /k m |
1 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 |
1 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 |
1 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 |
1 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 |
1 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 |
1 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 |
1 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 |
1 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
1 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 |
1 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
2 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
2 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 |
2 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
2 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
2 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 |
2 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 |
2 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
2 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
2 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 |
2 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
3 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
3 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 |
3 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
3 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
3 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
3 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 |
3 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
3 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
3 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 |
3 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
Phas e | Neutral | Phas e | Neutral |
Approx. Overall Diam eter |
Max. D.C. Res is tance of Conductor at 20ºC |
||||
AAC+UV-XLPE | AAAC | Com pact Conductor | UV-XLPE Ins ulation | Conductor | |||||
No.X Norm al Cr os s Section of Cores |
No.X Norm al Cr os s Section of Cores |
No.of Al.Wire | Overall Dia. | Norm al Thick nes s | Min. | No./Dia. of Al Alloy Wire | Phas e | Neutral | |
No. X m m 2 | No. X m m 2 | – | m m | m m | Min. | No./m m | m m | ohm /k m | ohm /k m |
1 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 12.3 | 1.91 | 2.217 |
1 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 14.7 | 1.2 | 1.393 |
1 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 17.3 | 0.868 | 1.007 |
1 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 20.1 | 0.641 | 0.744 |
1 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 23.1 | 0.443 | 0.514 |
1 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 27.3 | 0.32 | 0.371 |
1 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 30.2 | 0.253 | 0.294 |
1 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 33.95 | 0.206 | 0.239 |
1 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 37.7 | 0.164 | 0.19 |
1 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 43.05 | 0.125 | 0.145 |
2 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 14.04 | 1.91 | 2.217 |
2 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 16.63 | 1.2 | 1.393 |
2 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 19.51 | 0.868 | 1.007 |
2 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 22.46 | 0.641 | 0.744 |
2 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 25.7 | 0.443 | 0.514 |
2 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 30.31 | 0.32 | 0.371 |
2 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 33.41 | 0.253 | 0.294 |
2 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 37.55 | 0.206 | 0.239 |
2 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 41.69 | 0.164 | 0.19 |
2 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 47.41 | 0.125 | 0.145 |
3 X 16 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 0.98 | 7/1.70 | 16.15 | 1.91 | 2.217 |
3 X 25 | 1 X 25 | 7/2.24 | 6 | 1.2 | 0.98 | 7/2.10 | 19.06 | 1.2 | 1.393 |
3 X 35 | 1 X 35 | 7/2.58 | 7 | 1.4 | 1.16 | 7/2.50 | 22.32 | 0.868 | 1.007 |
3 X 50 | 1 X 50 | 7/3.00 | 8.3 | 1.4 | 1.16 | 7/3.00 | 25.59 | 0.641 | 0.744 |
3 X 70 | 1 X 70 | 19/2.15 | 9.8 | 1.4 | 1.16 | 7/3.50 | 29.22 | 0.443 | 0.514 |
3 X 95 | 1 X 95 | 19/2.58 | 11.6 | 1.6 | 1.34 | 19/2.50 | 34.42 | 0.32 | 0.371 |
3 X 120 | 1 X 120 | 18/3.00 | 13 | 1.6 | 1.34 | 19/2.80 | 37.87 | 0.253 | 0.294 |
3 X 150 | 1 X 150 | 30/2.58 | 14.6 | 1.8 | 1.52 | 37/2.25 | 42.56 | 0.206 | 0.239 |
3 X 185 | 1 X 185 | 36/2.58 | 16.2 | 2 | 1.7 | 37/2.50 | 47.25 | 0.164 | 0.19 |
3 X 240 | 1 X 240 | 36/3.00 | 18.4 | 2.2 | 1.88 | 61/2.25 | 53.63 | 0.125 | 0.145 |
Phase | Neutral | Service Connection | Phase | Neutral | Service Connection | Approx. Overall Diameter of Bundled Cable |
|||||
AAC+UV-XLPE | AAAC+UV-XLPE | AAC+UV-XLPE | Conductor | UV-XLPE | Conductor | UV-XLPE | Compact Conductor | UV-XLPE | |||
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No.X Normal Cross Section of Cores |
No. of Al. Wire | Overall Dia. | Normal | No./Dia. of Al. Wire | Normal | No. of Al. Wire | Overall Dia. | Normal | |
Thickness | Thickness | Thickness | |||||||||
No. X mm2 | No. X mm2 | No. X mm2 | – | mm | mm | mm | mm | No./mm | mm | mm | mm |
3 X 16 | 1 X 50 | 1 X 16 | 7/1.70 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 1 X 16 | 7/2.24 | 6 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 1 X 16 | 7/2.58 | 7 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 1 X 16 | 7/3.00 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 1 X 16 | 19/2.15 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 1 X 16 | 19/2.58 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 1 X 16 | 18/3.00 | 13 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 44.2 |
3 X 16 | 1 X 50 | 2 X 16 | 7/1.70 | 4.8 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 26.2 |
3 X 25 | 1 X 50 | 2 X 16 | 7/2.24 | 6 | 1.2 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 28.6 |
3 X 35 | 1 X 50 | 2 X 16 | 7/2.58 | 7 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 31.4 |
3 X 50 | 1 X 50 | 2 X 16 | 7/3.00 | 8.3 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 34 |
3 X 70 | 1 X 50 | 2 X 16 | 19/2.15 | 9.8 | 1.4 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 37 |
3 X 95 | 1 X 50 | 2 X 16 | 19/2.58 | 11.6 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 41.4 |
3 X 120 | 1 X 50 | 2 X 16 | 18/3.00 | 13 | 1.6 | 7/3.0 | 1.4 | 7/1.70 | 4.8 | 1.2 | 44.2 |
Executive Standard:ASTM
Code Word | AWG or k cm il | Bare neutral Mes s enger | Phas e conductor | Weight (k g/k m ) | ||
AAAC s trading and w ires dia(m m ) |
Rated Strength (lbs ) |
AAC s trading and w ires dia(m m ) |
ins ulation thick nes s (m m ) | |||
Bay | 3*6AWG+ 1*30.58 | 7/ 1.68 | 1110 | 1/4.11 | 1.14 | 207 |
French Coach | 3*6AWG+ 1*30.58 | 7/ 1.68 | 1110 | 7/ 1.56 | 1.14 | 2 13 |
German Coach | 3*4AWG+ 1*48.69 | 7/2. 12 | 1760 | 1/5.1 9 | 1.14 | 309 |
Arabian | 3*4AWG+ 1*48.69 | 7/2. 12 | 1760 | 7/ 1.96 | 1.14 | 316 |
Belgian | 3*2AWG+ 1*77.47 | 7/2.67 | 2800 | 7/2.47 | 1.14 | 476 |
Shet land | 3*1/0AWG+ 1*123.3 | 7/3.37 | 4460 | 19/ 1.89 | 1.52 | 768 |
Thoroughbred | 3*2/0AWG+ 1*155.4 | 7/3.78 | 5390 | 19/2.13 | 1.52 | 945 |
Trotter | 3*2/0AWG+ 1*195.7 | 7/4.25 | 6790 | 19/2.39 | 1.52 | 1166 |
Walking | 3*4/0AWG+ 1*246.9 | 7/4.77 | 8560 | 19/2.68 | 1.52 | 1442 |
Executive Standard:NFC
Des cr iption |
Nom inal cros s -s ection aera |
Wire num ber in Conductor | Max res is tance at 20 | Average diam eter of conductor |
Rated Strength | Average ins ulation thick nes s | |
m m 2 | No. | Ohm /k m | Min(m m ) | Max(m m ) | KN | m m | |
PHASE, NEUTRAL, |
16 | 7 | 1.91 | 4.6 | 5.1 | 1.9 | 1.2 |
25 | 7 | 1.2 | 5.8 | 6.3 | 1.4 | ||
35 | 7 | 0.868 | 6.8 | 7.3 | 1.6 | ||
50 | 7 | 0.641 | 7.9 | 8.4 | 1.6 | ||
70 | 12 | 0.443 | 9.7 | 10.2 | 1.8 | ||
95 | 19 | 0.32 | 11 | 12 | 1.8 | ||
120 | 19 | 0.253 | 12 | 13.1 | 1.8 | ||
150 | 19 | 0.206 | 13.9 | 15 | 1.7 | ||
PORTER | 54.6 | 7 | 0.63 | 9.2 | 9.6 | 1.6 | |
70 | 7 | 0.5 | 10 | 10.2 | 1.5 | ||
95 | 19 | 0.343 | 12.2 | 12.9 | 27.5 | 1.6 |
Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers’ requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics
Certifications
ISO9001:2008, OHSAS, CCC, TUV Certifications.
Package&Shipping:
For Package: Support to pack as rolls, or with wooden drum or wooden steel drums.
Shipment terms:
By FOB, CFR or CIF by sea.
By DHL, UPS, Fedex express etc are also available.
Our Services
Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 200,081 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;
4. Payment terms: T/T, L/C, O/A;
5. Guarantee: 20 years;
6. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
Customers Visiting:
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
We are China NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
ABC Cable 4X16sqmm Overhead Line Power Cable
Mv Aerial Bundled Conductor ABC Overhead Cables Distribution Line
Triplex Service Drop 0.6/1kv Cable
0.6/1kv 4 Core 35mm 50mm 70mm 95mm Aluminum Conductor X-90 Insulation Aerial Bundle Cable
LV Aerial Bundled Conductor 0.6/1kv-XLPE Insulation NFC 33-209
AAC AAAC Conductor XLPE PE PVC Insulated 0.6/1kv ABC Cable
Popular dycable Products
Overhead Service Aerial Bundled Cable ABC Cable
25mm2 35mm2 50mm2 70mm2 Service Drop Overhead Bunched Aerial Bundled ABC Cable
Bare Conductor ACSR Conductor Overhead Bare Steel Core Conductor
High Quality All Aluminium Conductor AAC Overhead Line Conductor
0.6/1kv Multicore Underground Cables PVC Cable, Electric Cable
ACSR Shepherd Conductor AWG 6 Duplex Service Drop
Popular NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line Cable Products
Popular XLPE Insulated Aerial Bundled Cable Products
0.6/1 Kv Aerial Bundled Cable, Quadruplex XLPE Insulated Cable
3 X150mm2 + 1 X 70mm2 XLPE Insulated Aerial Bundled Aluminum ABC Power Cable
NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line
0.6/1kv AAC Conductor XLPE Insulated Aerial Bundled Cable ABC Cable
Electrical Aluminium Conductor PE/XLPE Insulated ABC Cverhead Wire Cable
Service Drop Cable Areal Bundle Aluminum Cable ABC Aluminum Cable
Tags: ABC Cable, dycable, NFA2X AAC Conductor Self-Supporting Transmission Overhead ABC Drop Line Cable, XLPE Insulated Aerial Bundled Cable