Nyy Cu/PVC/PVC Low Voltage Power Insulted Electrical Cable
Nyy Cu/PVC/PVC Low Voltage Power Insulted Electrical Cable image
Get Latest Price Request a quote
Quick Details
Product Details
NYY CU/PVC/PVC Low Voltage Power Insulted Cable Construction:
Solid or Stranded Copper Conductor,PVC Insulation,PVC Outer Sheath
NYY CU/PVC/PVC Low Voltage Power Insulted Cable Standard:
IEC60502-1
NYY CU/PVC/PVC Low Voltage Power Insulted Cable Application:
NYY cables are used for electricity supply in low voltage installation system, Iec 60502-1 cables are
suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching
stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
NYY Cu/PVC/PVC Low Voltage Power Insulted Cable Technical Data:
Conductors: Copper or Aluminium conductor, round solid (Class 1)or standed(Class2) copper wire
Test Voltage: 4000V
Maxium Working Temperature:-70 º C
Short-circuit max. Conductor temperature:160°C
Insulation resistance: 20 MΩ x km
NYY Cu/PVC/PVC Low Voltage Power Insulted Cable Colour Code:
| Colour Code(1) | |
| 1 Core : | Red or Black |
| 2 Cores : | Red, Black |
| 3 Cores : | Red, Yellow, Blue |
| 4 Cores : | Red, Yellow, Blue, Black |
| 5 Cores : | Red, Yellow, Blue, Black, Green |
| Above 5 Cores: | Black Cores with White numerals |
| Colour Code (2) : | |
| 1 Core : | Brown or Blue |
| 2 Cores : | Brown or Blue |
| 3 Cores : | Brown, Black, Grey |
| 4 Cores : | Blue, Brown, Black, Grey |
| 5 Cores : | Green/Yellow, Blue, Brown, Black, Grey |
| Above 5 Cores: | Black Cores with White numerals |
NYY Cu/PVC/PVC Low Voltage Power Insulted Cable Parameter:
| Section | Conductor Diameter | Insulation Thickness | Sheath Thickness | Overall Diameter | Cable Weight | ||
| No.xmm² | mm | mm | mm | mm | Kg/Km | ||
| Single Core PVC Insulated Power Cable | |||||||
| 1×4 | 2.6 | 1 | 1.4 | 7.5 | 95 | ||
| 1×6 | 3.1 | 1 | 1.4 | 8 | 120 | ||
| 1×10 | 4 | 1 | 1.4 | 9 | 165 | ||
| 1×16 | 5 | 1 | 1.4 | 10 | 230 | ||
| 1×25 | 6.3 | 1.2 | 1.4 | 12 | 340 | ||
| 1×35 | 7.4 | 1.2 | 1.4 | 13 | 450 | ||
| 1×50 | 8.8 | 1.4 | 1.4 | 14.5 | 570 | ||
| 1×70 | 10.6 | 1.4 | 1.4 | 16 | 800 | ||
| 1×95 | 12.4 | 1.6 | 1.5 | 18.5 | 1070 | ||
| 1×120 | 14 | 1.6 | 1.5 | 20 | 1300 | ||
| 1×150 | 15.5 | 1.8 | 1.6 | 22 | 1600 | ||
| 1×185 | 17.4 | 2 | 1.7 | 24 | 1980 | ||
| 1×240 | 20.3 | 2.2 | 1.7 | 27 | 2560 | ||
| 1×300 | 22.7 | 2.4 | 1.8 | 30 | 3180 | ||
| 1×400 | 25.4 | 2.6 | 1.9 | 33 | 4060 | ||
| 1×500 | 28.8 | 2.8 | 2 | 37 | 5140 | ||
| 1×630 | 30.4 | 2.8 | 2.2 | 42 | 6600 | ||
| Two Cores PVC Insulated Power Cable | |||||||
| 2×1.5 | 1.6 | 0.8 | 1.8 | 12 | 205 | ||
| 2×2.5 | 2 | 0.8 | 1.8 | 13 | 250 | ||
| 2×4 | 2.6 | 1 | 1.8 | 15 | 330 | ||
| 2×6 | 3.1 | 1 | 1.8 | 16 | 400 | ||
| 2×10 | 4 | 1 | 1.8 | 18 | 525 | ||
| 2×16 | 5 | 1 | 1.8 | 20 | 720 | ||
| 2×25 | 6.3 | 1.2 | 1.8 | 24 | 1030 | ||
| 2×35 | 7.4 | 1.2 | 1.8 | 26 | 1320 | ||
| 2×50 | 8.8 | 1.4 | 1.8 | 29 | 1670 | ||
| 2×70 | 10.6 | 1.4 | 1.8 | 32 | 2290 | ||
| 2×95 | 12.4 | 1.6 | 1.9 | 37 | 3060 | ||
| 2×120 | 14 | 1.6 | 2 | 40 | 3700 | ||
| 2×150 | 15.5 | 1.8 | 2.2 | 44 | 4500 | ||
| 2×185 | 17.4 | 2 | 2.3 | 48 | 5570 | ||
| 2×240 | 20.3 | 2.2 | 2.5 | 55 | 7180 | ||
| Three Cores PVC Insulated Power Cable | |||||||
| 3×1.5 | 1.6 | 0.8 | 1.8 | 13 | 230 | ||
| 3×2.5 | 2 | 0.8 | 1.8 | 14 | 280 | ||
| 3×4 | 2.6 | 1 | 1.8 | 16 | 380 | ||
| 3×6 | 3.1 | 1 | 1.8 | 17 | 470 | ||
| 3×10 | 4 | 1 | 1.8 | 19 | 630 | ||
| 3×16 | 5 | 1 | 1.8 | 21 | 880 | ||
| 3×25 | 6.3 | 1.2 | 1.8 | 25 | 1280 | ||
| 3×35 | 7.4 | 1.2 | 1.8 | 27 | 1660 | ||
| 3×50 | 8.8 | 1.4 | 1.8 | 30 | 2110 | ||
| 3×70 | 10.6 | 1.4 | 1.9 | 35 | 2980 | ||
| 3×95 | 12.4 | 1.6 | 2 | 40 | 3930 | ||
| 3×120 | 14 | 1.6 | 2.1 | 43 | 4780 | ||
| 3×150 | 15.5 | 1.8 | 2.3 | 48 | 5880 | ||
| 3×185 | 17.4 | 2 | 2.4 | 52 | 7230 | ||
| 3×240 | 20.3 | 2.2 | 2.6 | 59 | 9390 | ||
| 3×300 | 22.7 | 2.4 | 2.7 | 65 | 11620 | ||
| 3×400 | 25.4 | 2.6 | 3 | 72 | 14730 | ||
| 3+1 Cores PVC Insulated Power Cable | |||||||
| 3 (mm) | 1 (mm) | 3 (mm) | 1 (mm) | ||||
| 3x 16/10 | 5 | 4 | 1 | 1 | 1.8 | 22 | 1000 |
| 3x 25/16 | 6.3 | 5 | 1.2 | 1 | 1.8 | 26 | 1460 |
| 3x 35/16 | 7.4 | 5 | 1.2 | 1 | 1.8 | 28 | 1830 |
| 3x 50/25 | 8.8 | 6.3 | 1.4 | 1.2 | 1.8 | 32 | 2410 |
| 3x 70/35 | 10.6 | 7.4 | 1.4 | 1.2 | 1.9 | 36 | 3360 |
| 3x 95/50 | 12.4 | 8.8 | 1.6 | 1.4 | 2.1 | 41 | 4440 |
| 3×120/70 | 14 | 10.6 | 1.6 | 1.4 | 2.2 | 46 | 5580 |
| 3×150/70 | 15.5 | 10.6 | 1.4 | 1.2 | 2.3 | 49 | 6580 |
| 3×185/95 | 17.4 | 12.4 | 1.6 | 1.4 | 2.5 | 54 | 8200 |
| 3×240/120 | 20.3 | 14 | 1.6 | 1.4 | 2.6 | 61 | 10570 |
| 3×300/150 | 22.7 | 15.5 | 1.8 | 1.6 | 2.8 | 67 | 13020 |
| 3×400/185 | 25.4 | 17.4 | 2 | 1.6 | 3.1 | 75 | 16560 |
| Four Cores PVC Insulated Power Cable | |||||||
| 4×1.5 | 1.6 | 0.8 | 1.8 | 14 | 265 | ||
| 4×2.5 | 2 | 0.8 | 1.8 | 15 | 325 | ||
| 4×4 | 2.6 | 1 | 1.8 | 17 | 450 | ||
| 4×6 | 3.1 | 1 | 1.8 | 18 | 560 | ||
| 4×10 | 4 | 1 | 1.8 | 20 | 770 | ||
| 4×16 | 5 | 1 | 1.8 | 23 | 1080 | ||
| 4×25 | 6.3 | 1.2 | 1.8 | 27 | 1580 | ||
| 4×35 | 7.4 | 1.2 | 1.8 | 30 | 2070 | ||
| 4×50 | 8.8 | 1.4 | 1.8 | 34 | 2680 | ||
| 4×70 | 10.6 | 1.4 | 2 | 38 | 3760 | ||
| 4×95 | 12.4 | 1.6 | 2.1 | 44 | 4960 | ||
| 4×120 | 14 | 1.6 | 2.3 | 48 | 6110 | ||
| 4×150 | 15.5 | 1.8 | 2.4 | 53 | 7450 | ||
| 4×185 | 17.4 | 2 | 2.6 | 58 | 9220 | ||
| 4×240 | 20.3 | 2.2 | 2.8 | 65 | 11900 | ||
| 4×300 | 22.7 | 2.4 | 3 | 72 | 14730 | ||
| 4×400 | 25.4 | 2.6 | 3.3 | 81 | 18830 | ||
| Multi-Cores PVC Insulated Power Cable | |||||||
| 5×1.5 | 1.6 | 0.8 | 1.8 | 15 | 300 | ||
| 7×1.5 | 1.6 | 0.8 | 1.8 | 16 | 360 | ||
| 10×1.5 | 1.6 | 0.8 | 1.8 | 19 | 460 | ||
| 12×1.5 | 1.6 | 0.8 | 1.8 | 20 | 510 | ||
| 14×1.5 | 1.6 | 0.8 | 1.8 | 20 | 570 | ||
| 19×1.5 | 1.6 | 0.8 | 1.8 | 22 | 710 | ||
| 21×1.5 | 1.6 | 0.8 | 1.8 | 23 | 770 | ||
| 24×1.5 | 1.6 | 0.8 | 1.8 | 25 | 870 | ||
| 30×1.5 | 1.6 | 0.8 | 1.8 | 26 | 1020 | ||
| 40×1.5 | 1.6 | 0.8 | 1.8 | 29 | 1290 | ||
| 48×1.5 | 1.6 | 0.8 | 1.8 | 32 | 1520 | ||
| 61×1.5 | 1.6 | 0.8 | 1.8 | 35 | 1900 | ||
| 5×2.5 | 2 | 0.8 | 1.8 | 16 | 375 | ||
| 7×2.5 | 2 | 0.8 | 1.8 | 17 | 460 | ||
| 10×2.5 | 2 | 0.8 | 1.8 | 20 | 590 | ||
| 12×2.5 | 2 | 0.8 | 1.8 | 21 | 660 | ||
| 14×2.5 | 2 | 0.8 | 1.8 | 22 | 740 | ||
| 19×2.5 | 2 | 0.8 | 1.8 | 24 | 940 | ||
| 21×2.5 | 2 | 0.8 | 1.8 | 25 | 1030 | ||
| 24×2.5 | 2 | 0.8 | 1.8 | 27 | 1150 | ||
| 30×2.5 | 2 | 0.8 | 1.8 | 29 | 1370 | ||
| 40×2.5 | 2 | 0.8 | 1.8 | 32 | 1810 | ||
| 48×2.5 | 2 | 0.8 | 1.8 | 36 | 2130 | ||
| 61×2.5 | 2 | 0.8 | 1.8 | 39 | |||
We are China Nyy Cu/PVC/PVC Low Voltage Power Insulted Electrical Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
4 Cores 50 Sqmm Overhead ABC Aerial Bundled Cable Insulated Electrical Power Cable Wire
Ymekrvasdlwd Fca 8, 7/15 Kv Longitudinal Water Blocking Power Cables
1/2/3/4/ 3+1/4+1core Aluminium Cable 95mm2 0.6/1kv Rated
XLPE Insulated Power Cable Best Quality Smart Power off Cable
Aluminum Tape Interlock/Welded Armoured Multi Thhn Inner Core Mc Cable
Overhead ACSR Conductor Service Drop Cable XLPE ABC Cable
Popular Insulted Cable Products
Na2xby XLPE Steel Tape Armored Insulted Power Cable
Popular jinlingcable Products
UL2586 Double Shield Underground Communication Date Cable UL 2586
Yy/Ysly Control Flexible Wire Cable
AAC AAAC ACSR Acar All Aluminium Conductor Alloy Overhead Bare Conductor 95mm Price
36kv Sac Cable Al/XLPE/XLPE (HDPE) Cable
PVC Insulated Oil-Proof Electrical Cord Wire Building Cable Wire
PV1-F H1z2z2-K Solar PV DC Cables Solar 6mm2
Popular Power Cable Products
0.6/1kv PVC Insulated Copper Conductor Nyy 4X16mm2 Power Cable
18/30kv Aluminum Cable 1X120mm2
0.6/1kv Cable-3.6/6kv Cable 4 Cores Al/PVC/Sta/PVC Steel Tape Armored Power Cable DIN VDE 0271
Water Proof Fire Resistant PVC Sheathed Control Electric Power Cable
Cu/XLPE/Cts/PVC/Sta/PVC, Power Cable, 8.7/15 (17.5) Kv, 3/C (IEC 60502-2)
Communication Cable XLPE Insulation Steel Armoured Power Cable
Tags: Cable, Insulted Cable, jinlingcable, Power Cable