Overhead Application and Aluminum Alloy Conductor AAAC 120mm
Overhead Application and Aluminum Alloy Conductor AAAC 120mm image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
Advantage:
1. AAAC exhibits excellent corrosion resistance specially in sea coast areas and in polluted industrial areas due to absence of steel core.
2. Since AAAC is homogeneous (with all strands of Aluminium Alloy) with no steel component the resistance of AAAC is lower as compared to ACSR.
3. Higher Ampacity: AAAC can carry atleast 15-20% extra current as compared to ACSR of equal size.
4. Experience in foreign countries shows that All Aluminium Alloy Conductors are in service for over 60 years, which is about double the life of ACSR Conductors.
Standard
IEC 61089, ASTM B399, BS 3242, BS EN50182, DIN 48201
| IEC 61089 | ||||||
| Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Linear Mass | Rated Strength | Max.DC Resistance at 20° C |
| mm2 | No./mm | mm | kg/km | KN | Ω/Km | |
| 10 | 10 | 7/1.35 | 4.05 | 27.4 | 1.95 | 2.8633 |
| 16 | 16 | 7/1.71 | 5.13 | 43.8 | 3.04 | 1.7896 |
| 25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
| 40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
| 63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.39 | 0.4545 |
| 100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
| 125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.25 | 0.2302 |
| 160 | 160 | 19/3.27 | 16.35. | 439.8 | 26.4 | 0.1798 |
| 200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
| 250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
| 315 | 315 | 37/3.29 | 23.03 | 867.9 | 51.97 | 0.0916 |
| 400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
| 450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
| 500 | 500 | 37/4.15 | 29.05. | 1377.6 | 80 | 0.0577 |
| 560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
| 900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
| 1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
| 1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250 | 91/4.18 | 45.98. | 3452.6 | 200 | 0.0231 |
| 1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
| 1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
| AAAC conductor-ASTM B 399B 399M | |||||||
| Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | |
| AWG&MCM | mm^2 | No.xmm | mm | kg/km | KN | Ω/Km | A |
| 6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 |
| 4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 |
| 2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 |
| 0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 |
| 2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 |
| 3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 |
| 4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 |
| 250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 |
| 300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 |
| 350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 |
| 400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 |
| 450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 |
| 500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 |
| 550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 |
| 600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 |
| 650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 |
| 700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 |
| 750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 |
| 800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 |
| 900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 |
| 1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 |
| 1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 |
| 1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 |
| 1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |
| ASTM B 399/B 399M | ||||||||
| Code Name | Total Area | 1350 Grade Equivalent | No./Dia. of Wire |
Approx. Overall Diameter | Approx. Weight | Calculated Breaking Load |
Max.DC Resistance at 20° C | |
| AWG or MCM | mm2 | (Approx.) AWG or MCM |
No. / mm | mm | kg/km | kN | Ohm/km | |
| Akron | 30.6 | 15.5 | 6 | 7/1.68 | 5.04 | 43 | 4.9 | 2.1588 |
| Alton | 48.7 | 24.7 | 4 | 7/2.12 | 6.36 | 68 | 7.8 | 1.3557 |
| Ames | 77.5 | 39.2 | 2 | 7/2.67 | 8.01 | 108 | 12.4 | 0.8547 |
| Azusa | 123.3 | 62.4 | 1 | 7/3.37 | 10.11 | 171 | 18.9 | 0.5365 |
| Anaheim | 155.4 | 78.6 | 2/0 | 7/3.78 | 11.34 | 216 | 23.8 | 0.4264 |
| Amherst | 195.7 | 99.3 | 3/0 | 7/4.25 | 12.75 | 272 | 30 | 0.3373 |
| Alliance | 246.9 | 125.1 | 4/0 | 7/4.77 | 14.31 | 343 | 37.8 | 0.2678 |
| Butte | 312.8 | 158.6 | 266.8 | 19/3.26 | 16.3 | 435 | 46.5 | 0.2112 |
| Canton | 394.5 | 199.9 | 336.4 | 19/3.66 | 18.3 | 548 | 58.6 | 0.1676 |
| Cairo | 465.4 | 236.4 | 397.5 | 19/3.98 | 19.9 | 649 | 69.3 | 0.1417 |
| Darien | 559.5 | 283.6 | 477 | 19/4.36 | 21.8 | 778 | 83.1 | 0.1181 |
| Elgin | 652.6 | 331 | 556.5 | 19/4.71 | 23.55 | 908 | 97 | 0.1012 |
| Flint | 740.8 | 374.5 | 636 | 19/3.59 | 25.13 | 1028 | 107.4 | 0.0894 |
| Greeley | 927.2 | 469.6 | 795 | 19/4.02 | 28.14 | 1289 | 134.6 | 0.0713 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Overhead Application and Aluminum Alloy Conductor AAAC 120mm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 120mm Aluminum Alloy Electrical Wire Products
Popular Aluminum Conductor AAAC 120mm Products
70mm2 AAAC Conductor AAC Concrete Overhead Application and Aluminum Conductor AAAC 120mm
Overhead Application and Aluminum Alloy Conductor AAAC 120mm Electrical Wire
Popular kingyear Products
450/750V 10 Core 1.5mm2 XLPE or PVC Insulated and Sheathed Flexible Copper Control Cable
AAC Conductor En 215 All Aluminum Conductor Stranded Bare Conductor for Overhead Lines
Low or Medium Voltage Cable 3 Cores Cable with Armor and XLPE Insulation Underground
4X70mm2 Sta/Swa Armored Power Cable XLPE/PVC Insulated 4 Core Electrical Power Cable
ISO ABC Cable CE Certified Cherrystone Cockle for Overhead Insulated Cable
Popular Overhead Application AAAC Wire Factory Price Products
Overhead Application and Aluminum Alloy Conductor AAAC 120mm Electrical Wire
Tags: 120mm Aluminum Alloy Electrical Wire, Aluminum Conductor AAAC 120mm, kingyear, Overhead Application AAAC Wire Factory Price