Product Details

Overhead Bare Conductor AAC Tulip

Productor description:

1.Aluminum conductor and Alumum Alloy Conductor 
(1). All aluminium conductor (AAC) 
(2). All aluminimum alloy conductor(AAAC) 
(3). Aluminum conductor steel reinforced (ACSR) 
(4). Anti-corrosion type ACSR 
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW) 
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE) 
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR) 

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204. 
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182. 
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied. 
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels. 

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 
(AAAC) Conductor as per ASTM-B-399-1992 
(AAAC) Conductor as per BS-3242-1970 
(AAAC) Conductor IS: 398-IV-1994 
(ACSR) as per ASTM-B-233-1992 
(AAC) as per BS-215-1-1970 
(AAC) as per IS-398-1: 1976 
(AAC) as per ASTM-B-231-1990 
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 
(ACSR) BS-215-II-1970 
(AACSR) as per IEC-1089-1191 

AAC(All aluminum conductor) are suited for overhead power line. 

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power. 

Applications: 
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Construction: 
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. 

Specifications: 
ACSR bare conductor meets or exceeds the following ASTM specifications: 
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) 
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) 

Notes: 
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

What are Aluminium Conductors used for?

Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution. 

The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity. 

AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to. 

AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.

What is the difference between ACSR, AAC and AAAC Conductors?

The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel. 

The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium. 

In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.

What do ACSR, AAC and AAAC Conductors have in common?

ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.

 Bare conductors are designed and manufactured according to customer’s special request .

 

We are China Overhead Bare Conductor AAC Tulip manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular AAAC Conductor Products

Aluminum Overhead Conductor, AAC, AAAC, ACSR Conductors Manufacturer

All Aluminum Alloy Conductor AAAC

1370 1350 All Alloy Aluminum AAAC Cable, IEC ASTM BS DIN Standard Conductor

German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 16mm2

IEC Stabdard AAAC Bare Conductor for Transmission

AAAC/11 20 Conductors as 1 531 Chlorine Chromium Fluorine Helium Hydrogen AAAC Aluminum Alloy

Popular AAC Conductor Products

AAC Conductor for Overhead

All Aluminum Conductor (AAC) &Aluminum Conductor Steel Reinforced (ACSR)

Turkey Bare Overhead AAAC Conductor ACSR Conductors

Overhead ACSR Aluminum Conductor 120/70mm2

Bare Conductor 100mm2 7/4.39 AAC Wasp Bare Cable

as Standard ACSR Apricot Bare Overhead Conductor

Popular ACSR Conductor Products

IEC Standard Aluminum Conductor ACSR 250mm2

ACSR Sapsucker Goose Goldfinch Gull Crow Conductor

ACSR Aluminum Clad Steel Reinforced Bare Conductor ASTM Standard

ASTM/BS/IEC Standard ACSR AAAC AAC Overhead Bare Conductor

BS 215 100mm2 6/4.72 7/1.57 ACSR Dog Conductor Price List

600/1000V Bare AAC/AAAC/ACSR Cable BS Standard ACSR Conductor

Popular yifangcable Products

ABC Cable (JKLV) Duplex. Triplex, Quadruplex Cable

High Quality All Aluminium Conductor

Multi Cores XLPE Insulated Power Cable Aluminium Cable 4X70mm 4X150mm2

ABC Cable

33kv 3X240mm2 XLPE Underground Cable

Low Voltage PVC Insulated PVC Sheathed Cable