Overhead Bare Conductor ACSR Moose
Overhead Bare Conductor ACSR Moose image
Get Latest Price Request a quote
Quick Details
Product Details
Overhead Bare Conductor ACSR moose
Productor description:
1.Aluminum conductor and Alumum Alloy Conductor
(1). All aluminium conductor (AAC)
(2). All aluminimum alloy conductor(AAAC)
(3). Aluminum conductor steel reinforced (ACSR)
(4). Anti-corrosion type ACSR
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
What are Aluminium Conductors used for?
Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution.
The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity.
AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to.
AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.
What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.
What do ACSR, AAC and AAAC Conductors have in common?
ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.
Bare conductors are designed and manufactured according to customer’s special request .
We are China Overhead Bare Conductor ACSR Moose manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Conductor Products
Types of AAAC Conductor Aluminum Alloy Conductor
AAAC All Alloy Aluminum Conductor with BS En50183 Standard
DIN 48201 AAAC Conductor-All Aluminum Alloy Conductor AAAC 70mm2
ASTM B232 Standard Bare Conductor Aluminum Conductor Steel Reinforced ACSR Conductor
Overhead Application and Aluminum Conductor Material ACSR /AAC/AAAC Conductor Products
4AWG Alton ASTM Standard Aluminium Alloy Conductor AAAC Conductor
Popular AAC Conductor Products
Low Voltage 0.6/1kv Ume Brand Bare Aluminum Conductor Aluminum Conductor AAC
BS Standard AAC All Aluminium Conductor
300mcm Peony AAC All Aluminum Stranded Bare Conductor Overhead Cable
Hard Drawn Aluminum Conductor Hda Conductor AAC Conductor for Transmission
Aluminum Bare Stranded Cable AAC Conductor for Overhead Use Tender
ASTM Standard 8030, 6201 AAAC Alloy Overhead Bare Conductor
Popular ACSR Conductor Products
Overhead ACSR, AAC, AAAC, Acss/Tw, Accc, Aacsr, Acar, Opgw Bare Conductor
600/1000V Bare ACSR Cable BS Standard ACSR Conductor
CSA C49 Canadian Standard Overhead Conductor ACSR Conductor ACSR Cable
ACSR Asc Cable Aluminum Conductor ACSR Bare Conductor
BS 215 Standard Racoon 75mm2 Aluminum Conductor Steel Reinforced ACSR Bare Conductor Cable
ASTM B-231 AAC AAAC ACSR All Aluminum Bare Conductor
Popular yifangcable Products
66kv 110kv 132kv 220kv Copper Conductor XLPE Insulated Power Cable (YJV22)
XLPE Insulation Service Drop Cable
PE Insulation Mutlipairs Screened Instrument Cable with Steel Wire Armor
18/30 Kv Na2xsy 1*120mm2 3*95mm2 Industry Electric Power Cable
Alumimiun Bear Conductor Galvanized Steel Stay Gay Wire
Tags: AAAC Conductor, AAC Conductor, ACSR Conductor, yifangcable