Construction:
Conductors are concentric stranded or compressed conductors of aluminum 1350-H19 covered for weather proofing with polyethylene, High Density polyethylene (HDPE) or Cross-linked polyethylene (XLPE) insulation, concentric stranded AAC,ACSR or 6210 AAAC alloy neutral messenger.
Applications:
Duplex Service Drop is to supply 120V or 240V and below aerial service for temporary service at construction sites, outdoor or street lighting, for service at 600V or below at a conductor temperature of 70ºC maximum for polyethylene insulation , or 90ºC maximum for cross-linked polyethylene insulation.
Standards:
Duplex service drop cable meets or exceeds the following ASTM specifications:
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-399 Concentric-Lay-Stranded Aluminum Alloy Conductors 6201-T81.
Service drop conductor meets or exceeds all applicable requirement of ANSI/ ICEA-S-76-474:
Ampacity rating base on 75ºC conductor temperature; 25ºC ambient temperature. Emissivity 0.91 and coefficient of absorbtion of 0.95.
| Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | |||||||
| Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Insul. Thick. (mils) | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
| 6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
| Chihuahua | 6 | 1 | 45 | 6 | 30.58 | 7 | 1110 | 65 | 65 | 85 | 70 |
| Vizsla | 6 | 7 | 45 | 6 | 30.58 | 7 | 1110 | 68 | 68 | 85 | 70 |
| Harrier | 4 | 1 | 45 | 4 | 48.69 | 7 | 1760 | 99 | 99 | 115 | 90 |
| Whippet | 4 | 7 | 45 | 4 | 48.69 | 7 | 1760 | 103 | 103 | 115 | 90 |
| Schnauzer | 2 | 7 | 45 | 2 | 77.47 | 7 | 2800 | 157 | 157 | 150 | 120 |
| Heeler | 1/0 | 9 | 60 | 1/0 | 123.3 | 7 | 4460 | 250 | 250 | 205 | 160 |
| * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++ Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. | |||||||||||
| Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | ||||||
| Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
| AAC NEURAL-MESSENGER | ||||||||||
| Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 61 | 61 | 85 | 70 |
| Collie | 6 | 7 | 45 | 6 | 7 | 563 | 64 | 64 | 85 | 70 |
| DachShund | 4 | 1 | 45 | 4 | 7 | 881 | 92 | 92 | 115 | 90 |
| Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 96 | 96 | 115 | 90 |
| Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 147 | 147 | 150 | 120 |
| Bull | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 234 | 234 | 205 | 160 |
| * Code Words For XLP Insulated Products Are Formed By Adding "/XLP" to the Conventional Code Words Above (e.g.-Chihuahua/XLP).+ Conductor Temperature of 90°C For XLP, 75°C For Poly; Ambient Temperature of 40°C; Emissivity 0.9; 2 ft./sec. Wind In Sun. | ||||||||||
| Code Word | Phase Conductor | Bare Neutral Messenger | Weight Per 1000 ft. (lbs.) | Allowable Ampacity+ | ||||||
| Size (AWG or kcmil) | Stranding | Insul. Thick. (mils) | Size (AWG) | Strand- ing | Rated Strength (lbs.) | XLP | POLY | XLP | POLY | |
| ACSR NEUTRAL-MESSENGER | ||||||||||
| Setter | 6 | 1 | 45 | 6 | 6/1 | 1190 | 72 | 72 | 85 | 70 |
| Shepherd | 6 | 7 | 45 | 6 | 6/1 | 1190 | 75 | 75 | 85 | 70 |
| Eskimo | 4 | 1 | 45 | 4 | 6/1 | 1860 | 110 | 110 | 115 | 90 |
| Terrier | 4 | 7 | 45 | 4 | 6/1 | 1860 | 115 | 115 | 150 | 120 |
| Chow | 2 | 7 | 45 | 2 | 6/1 | 2850 | 176 | 176 | 150 | 120 |
| Bull | 1/0 | 9 | 60 | 1/0 | 6/1 | 4380 | 280 | 280 | 205 | 160 |
| * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. | ||||||||||
We are China Overhead Transmission Aluminium Cable Duplex Service Drop ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cables Products
Overhead Transmission Line ABC Aerial Bunched Cables
Shepherd Core XLPE Insulated Overhead ABC Cable
ABC Cables Overhead Aerial Bundle Cable
Hersatene Rhvs Aluminium 12/20 Kv XLPE Insulated Overhead A2xs2yt Cable
3 Core XLPE Insulated Aluminum Twisted Cables - ABC
Mv Aerial Bundled Conductor ABC Cables for Overhead Distribution Lines
Popular Aerial Bundled Cable Products
ABC Cable, Aerial Bundle Cable. Triplex Service Drop Cable Gammarus,
Aerial Bundled Cable XLPE Insulated 2*50mm2 - AS/NZS 3560.1
Triplex ABC Cable---Aerial Bundled Conductor
China Cable Factory Overhead Insulated Aerial Bundled Cable/ABC Cable/Service Drop Cables
Aerial Bundled Cable - IEC 60502
Popular jytopcable Products
Low Voltage LV Copper XLPE Insulated PVC Sheathed Electric Power Cable
Low Voltage Control Cable with PVC Insulated
BVVB Flat Twin PVC Insulated PVC Sheathed Cable
Low Voltage1kv Nyy N2xy Copper Cable with CE Certificate
450V Flame Retardant Control Cable
Popular Overhead Cable Products
Standard Power Transmission Line Aluminum AAC/AAAC/ACSR Overhead Bare Conductor
Overhead Triplex Service Drop Cable
Cable Autoportante Tipo Caai-S VW-1 0, 6/1 Kv with Public Lighting Caai Cable
70sqmm Horse BS Standard Aluminum Conductor Steel Reinforeced ACSR Hot Product
Overhead Aluminum Covered Line Wire ABC Cable
Tags: ABC Cables, Aerial Bundled Cable, jytopcable, Overhead Cable