1. 0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
2. Surge Arrester Technical Parameters:
Type |
MOA rated voltage
|
MCOV | Current impulse residual voltage |
2ms |
4/10us high |
||
1/4us lighting |
8/20us lighting |
30/60us switching |
|||||
kV(rms) | kV(rms) | kV(crest) | kV(crest) | kV(crest) | kV(crest) | kV(crest) | |
YH5W-3 | 3 | 2.55 | 11.3 | 9 | 8.9 | 150/250 | 65/100 |
YH5W-6 | 6 | 5.1 | 22.6 | 18 | 16.8 | 150/250 | 65/100 |
YH5W-9 | 9 | 7.65 | 33.7 | 27 | 23.8 | 150/250 | 65/100 |
YH5W-10 | 10 | 8.4 | 36 | 30 | 23 | 150/250 | 65/100 |
YH5W-12 | 12 | 10.2 | 42.2 | 36 | 27 | 150/250 | 65/100 |
YH5W-15 | 15 | 12.7 | 51 | 45 | 38.5 | 150/250 | 65/100 |
YH5W-18 | 18 | 15.3 | 61.5 | 54 | 46.2 | 150/250 | 65/100 |
YH5W-21 | 21 | 17.0 | 71.8 | 63 | 54.2 | 150/250 | 65/100 |
YH5W-24 | 24 | 19.5 | 82 | 72 | 62 | 150/250 | 65/100 |
YH5W-27 | 27 | 22.0 | 92 | 81 | 69.8 | 150/250 | 65/100 |
YH5W-30 | 30 | 24.4 | 102 | 90 | 79 | 150/250 | 65/100 |
YH5W-33 | 33 | 27.5 | 112 | 99 | 86.7 | 150/250 | 65/100 |
YH5W-36 | 36 | 29.0 | 123 | 108 | 92.4 | 150/250 |
65/100 |
3. Surge Arrester Working Condition:
Environment temperature: -40–+40 degree |
altitude:<1000m |
48HZ<Rated frequency<62HZ |
Power frequency voltage should not be more than continuous running voltage |
Max wind speed should be less than 35m/s |
Earthquake intensity should be less than 7 degree |
If used in contamination area, should be noted in advance. |
4. Other Surge Arrester
Company Information
Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. We are one of the recommended model companies for national power grid of China. Our company is the professional manufacturer of 0.22KV-500KV metal oxide surge arresters, Zinc oxide varistors, 10-220KV outdoor disconnectors, earthing switches, composite insulators and fuse cutouts.
Yongde sticks to the quality policy of "being the technical forerunner, supreme in quality, supremacy of customers, and innovative progressing", so that our products and services successfully satisfy our users. We warmly welcome friends and customers from at home and abroad to contact us for exchange and corporation. We also welcome the feedback from our users.
Production Lead Time & Quality Guarantee:
1. Sample deliery time is about 2-3 days;
big order quantity is about 30-35 days after we receive 30%~50% deposit from you.
Generally, it takes 4 working days by DHL/UPS, and 7-10 days by EMS.
2. 12 months’ warranty period. 20 years’ quality guarantee period
With ISO9001:2008approvals.
Customer Services:
Our salesmen will reply your inquiry within 24 hours. Any order is welcome. If you like to be our agent in your country, we can give you any support on the technique & other aspects.
We are China Polymeric Housing Metal Oxide Surge Arrester for Low Voltage System manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Arreste Products
Popular hzyddq Products
Polymeric Zinc Oxide Surge Arrester 24kv 5ka for Electrical Substation
Substation 11kv/15kv Ceramic Silicone Lightning Surge Arrester with Bracket
132kv Transmission Line Type 24kv 10ka Lightning Arrester Without Gap
220KV Porcelain Housed Station Surge Arrester
Silicon Rubber Insulator Post Insulator
Motor-Driven Operating Mechanism Boxes for Earthing Switch
Popular Lightning Protection Products
Electrical Component Light Diverter Lightning Protection with Cap
Electrical Transformer Type High Quality Lightning Protection Materials
3-36kv Composite Moa Thunder Gapless Surge Arrester for Transmission Line
Rated Voltage 15kv/Nominal Current 10ka Surge Arrester
Lightning Protection Products Silicone Arrester with Kema Type Test Report
Transformer Type Medium Voltage Class1 24kv Surge Arrestor with Kema
Popular Surge Arrester Products
Hy1.5W-0.5/2.6 Zinc-Oxide Arrester
Kema 11kv Surge Arrester Zinc Oxide Lightning Arrester
Line 2ms Current 600A Porcelain Composite Polymer Surge Absorber
220KV Porcelain Housed Station Surge Arrester
11kv/24kv Station Class Polymeric Lightning Arrester with Bracket
6kv Polymeric Housed Metal-Oxide Surge Arrester Without Gaps
Tags: Arreste, hzyddq, Lightning Protection, Surge Arrester