All Aluminum Conductor is used in overhead electric power transmission and distribution lines with various grade voltage. It can replace part of the aluminum conductors or ACSR for overhead distribution lines. Temperature for continuous use is up to 90.C, Temperature of heat-resistant aluminum alloy strands is up to 150.C and above. it has high current carrying capacity and good corrosion performance.
Specification
Area:from 10mm2 to 1500mm2 The detailed speicification is as follows.
All Aluminum stranded conductor according to ASTM B231
Code name | Total Area | Stranding and wire diameter | Approox. Overall diameter | Weight | Nominal breaking load | Nom. DC resistance at 20 deg. | |
AWG or MCM | mm2 | mm | mm | kg/km | daN | ohm/km | |
PEACHBELL | 6 | 13.29 | 7/1.554 | 4.67 | 37 | 249 | 2.1692 |
ROSE | 4 | 21.16 | 7/1.961 | 5.89 | 58 | 396 | 1.3624 |
IRIS | 2 | 33.61 | 7/2.474 | 7.42 | 93 | 597 | 0.8577 |
PANSY | 1 | 42.39 | 7/2.776 | 8.33 | 117 | 732 | 0.6801 |
POPPY | 1/0 | 53.48 | 7/3.119 | 9.36 | 147 | 873 | 0.539 |
ASTER | 2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 1100 | 0.4276 |
PHLOX | 3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 1347 | 0.339 |
OXLIP | 4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 1698 | 0.2688 |
VALERIAN | 250 | 126.71 | 19/2.913 | 14.57 | 349 | 2062 | 0.2275 |
SNEEZEWORT | 250 | 126.71 | 7/4.80 | 14.4 | 349 | 2007 | 0.2275 |
LAUREL | 266.8 | 135.16 | 19/3.01 | 15.05 | 373 | 2200 | 0.2133 |
DAISY | 266.8 | 135.16 | 7/4.96 | 14.9 | 373 | 2141 | 0.2133 |
PEONY | 300 | 152.0 | 19/3.193 | 15.97 | 419 | 2403 | 0.1896 |
TULIP | 336.4 | 170.45 | 19/3.381 | 16.91 | 470 | 2695 | 0.1691 |
DAFFODIL | 350 | 177.35 | 19/3.447 | 17.24 | 489 | 2804 | 0.1625 |
CANNA | 397.5 | 201.42 | 19/3.673 | 18.36 | 555 | 3184 | 0.1431 |
GOLDENTUFT | 450 | 228.0 | 19/3.909 | 19.55 | 629 | 3499 | 0.1264 |
SYRINGA | 477 | 241.68 | 37/2.882 | 20.19 | 666 | 3849 | 0.1193 |
COSMOS | 477 | 241.68 | 19/4.023 | 20.12 | 666 | 3708 | 0.1193 |
HYACINTH | 500 | 253.35 | 37/2.951 | 20.65 | 698 | 4035 | 0.1138 |
All Aluminum stranded conductor according to IEC61089
Sectional area | Conductor qty/diameter | Outer diameter | Measured sectional | Approx weight | 20 ºC DC | 90ºC ampacity |
(mm2) | (mm) | (mm) | area | (kg/km) | max resistance | |
(mm2) | (Ω/km) | |||||
16 | 7/1.70 | 5.1 | 15.89 | 43.5 | 1.802 | 110 |
25 | 7/2.15 | 6.45 | 25.41 | 69.6 | 1.127 | 145 |
35 | 7/2.50 | 7.5 | 34.36 | 94.1 | 0.8332 | 180 |
50 | 7/3.00 | 9 | 49.48 | 135.5 | 0.5786 | 225 |
70 | 7/3.60 | 10.8 | 71.25 | 195.1 | 0.4018 | 285 |
95 | 7/4.16 | 12.48 | 95.14 | 260.5 | 0.3009 | 340 |
120 | 19/2.85 | 14.25 | 121.24 | 333.5 | 0.2373 | 390 |
150 | 19/3.15 | 15.75 | 148.07 | 407.4 | 0.1943 | 455 |
185 | 19/3.50 | 17.75 | 182.8 | 503 | 0.1574 | 520 |
210 | 19/3.75 | 18.75 | 209.85 | 577.4 | 0.1371 | 575 |
240 | 19/4.00 | 20 | 238.76 | 656.9 | 0.1205 | 610 |
300 | 37/3.20 | 22.4 | 297.57 | 820.4 | 0.09689 | 710 |
400 | 37/3.70 | 25.9 | 397.83 | 1097 | 0.07247 | 850 |
500 | 37/4.16 | 29.12 | 502.9 | 1387 | 0.05733 | 980 |
630 | 61/3.63 | 32.67 | 631.3 | 1744 | 0.04577 | 1140 |
800 | 61/4.10 | 36.9 | 805.36 | 2225 | 0.03588 | 1340 |
All Aluminum Alloy stranded conductor according to BS EN50183
Code name | Area | Diameter | Approox. Overall diameter | Weight | Nominal breaking load | Nom. DC resistance at 20 deg. | |
Wire | Cond. | ||||||
mm2 | mm | mm | mm | kg/km | kN | ohm/km | |
BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.748 |
ACACLA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
HAZEL | 59.9 | 7 | 3.3 | 9.9 | 163.4 | 17.66 | 0.5494 |
PLNE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245 | 26.47 | 0.3665 |
OAK | 118.9 | 7 | 4.65 | 14 | 324.5 | 35.07 | 0.2767 |
MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.183 |
ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
SYCAMORE | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.4 | 0.1095 |
UPAS | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
YEW | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
TOTARA | 498.1 | 37 | 4.14 | 29 | 1372.1 | 146.93 | 0.0666 |
RUBUS | 586.9 | 61 | 3.5 | 31.5 | 1622 | 173.13 | 0.0567 |
SORBUS | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
ARAUCARIA | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
REDWOOD | 996.2 | 61 | 4.56 | 41 | 2753.2 | 293.88 | 0.0334 |
Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminum conductor steel supported (ACSS)
(9) aluminum conductor carbon core(ACCC)
About Us
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Our mainly products as follow:
1–pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2–pvc and xlpe insulated power cable with or without armor upto 35kv.
3–rubber cable like welding cable, mine cable, EPR cable and so on.
4–aerial bundled cable(ABC cable) up to 10kv.
5–bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Packing & Delivery
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
Certification
We have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test.
Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
FAQ
Q:I didn’t find the cable which I need in this page?
A:If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What’s your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What’s your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
Welcome your inquiry! Any question please feel free to contact me.
We are China Popular Aluminum AAC AAAC Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Products
DIN 48201 95/15 All Aluminium Bare Conductor
Round Wire Concentric Lay Aerial Electrical Stranded Conductor IEC 61089
Lowest Price (all aluminum conductor) AAC Electric Cable Wire
ASTM BS Standard All Aluminum Conductor AAC AAAC Acar ACSR
ASTM B231 BS215 Power Line Conductor, Asc / AAC Conductors Used in Transmission Lines
0.6/1kV ABC Aerial Cable 3X50+35mm2, Overhead Spacer Cable
Popular Bare Conductor Products
AAAC 2AWG, 4AWG, 2/0AWG, 4/0AWG Overhead Bare Conductor Astmb399
DIN48201 185sqmm Aerial All Aluminum AAC Conductor
ACSR Hare Conductor (Aluminium Conductor Steel Reinforced)
High Voltage Overhead Cable ACSR Steel Wire Reinforced Cable Code Wren ASTM Standard
BS Standard AAAC Deodar Conductor Bare Aluminum Alloy Conductor
Cable Factory ASTM Standard Bare Copper Earth Wire/Ground Conductor 50mm2
Popular kingyear Products
8 Core Silicone Rubber Cable for Auto Control Armoured
2*120mm2 ABC Duplex Aluminum Overhead Cable
XLPE Power Cable 3c 95mm2 4 Core 50mm2 3X95 Power Cable
11kv ABC Cable 3 Core Aerial Bundled Cable
ASTM BS IEC Standards Overhead Bare Aluminium ACSR Conductor
Mirror Polished Aluminum Alloy, Aluminum Circle, Aluminum Sheet Price
Popular Overhead Conductor Products
ASTM B-231 AAC AAAC ACSR All Aluminum Bare
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Quail
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Catbird
Aluminum Electrical Cable Manufacturer AAC, AAAC, ABC, ACSR Conductor
Triplex Service Drop ACSR Neutral Conductor Cuttlefish
Triplex Service Drop ACSR Neutral Conductor Cavolinia
Tags: AAC, Bare Conductor, kingyear, Overhead Conductor