Product Description
ONE-STOP SOLUTIONS FOR WIRES&CABLES – HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
AAC Conductor has been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity.
2. Construction
These aluminium conductors are made up of one or more aluminium wires strands depending on their usage.
3. Standards
IEC 61089, DIN 48201-5, AS 1531, BS EN 50182, ASTM B231, GB/T 1179
IEC 61089
| Code Name |
Nominal Area |
No. & Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
| mm2 | No./mm | mm | kg/km | kN | Ω/km | |
| 10 | 10.0 | 7/1.35 | 4.05 | 27.4 | 2.0 | 2.8633 |
| 16 | 16.0 | 7/1.71 | 5.13 | 43.8 | 3.0 | 1.7896 |
| 25 | 25.0 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
| 40 | 40.0 | 7/2.70 | 8.10 | 109.4 | 6.8 | 0.7158 |
| 63 | 63.0 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
| 100 | 100.0 | 19/2.59 | 12.95 | 274.8 | 17.0 | 0.2877 |
| 125 | 125.0 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
| 160 | 160.0 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
| 200 | 200.0 | 19/3.66 | 18.30 | 549.7 | 32.0 | 0.1439 |
| 250 | 250.0 | 19/4.09 | 20.45 | 687.1 | 40.0 | 0.1151 |
| 315 | 315.0 | 37/3.29 | 23.03 | 867.9 | 52.0 | 0.0916 |
| 400 | 400.0 | 37/3.71 | 25.97 | 1102.0 | 64.0 | 0.0721 |
| 450 | 450.0 | 37/3.94 | 27.58 | 1239.8 | 72.0 | 0.0641 |
| 500 | 500.0 | 37/4.15 | 29.05 | 1377.6 | 80.0 | 0.0577 |
| 560 | 560.0 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630.0 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710.0 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800.0 | 61/4.09 | 36.81 | 2207.4 | 128.0 | 0.0361 |
| 900 | 900.0 | 61/4.33 | 38.97 | 2483.3 | 144.0 | 0.0321 |
| 1000 | 1000.0 | 61/4.57 | 41.13 | 2759.2 | 160.0 | 0.0289 |
| 1120 | 1120.0 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250.0 | 91/4.18 | 45.98 | 3452.6 | 200.0 | 0.0231 |
| 1400 | 1400.0 | 91/4.43 | 48.73 | 3866.9 | 224.0 | 0.0207 |
| 1500 | 1500.0 | 91/4.58 | 50.38 | 4143.1 | 240.0 | 0.0193 |
DIN 48201-5
| Area | No. & Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
|
| Nominal | Actual | |||||
| mm2 | mm2 | No./mm | mm | kg/km | kN | Ω/km |
| 16 | 15.9 | 7/1.70 | 5.10 | 43.0 | 2.8 | 1.8022 |
| 25 | 24.3 | 7/2.10 | 6.30 | 66.0 | 4.2 | 1.1810 |
| 35 | 34.4 | 7/2.50 | 7.50 | 94.0 | 5.8 | 0.8333 |
| 50 | 49.5 | 7/3.00 | 9.00 | 135.0 | 7.9 | 0.5787 |
| 50 | 48.4 | 19/1.80 | 9.00 | 133.0 | 8.5 | 0.5951 |
| 70 | 65.8 | 19/2.10 | 10.50 | 181.0 | 11.3 | 0.4372 |
| 95 | 93.3 | 19/2.50 | 12.50 | 256.0 | 15.7 | 0.3085 |
| 120 | 117.0 | 19/2.80 | 14.00 | 322.0 | 18.8 | 0.2459 |
| 150 | 147.1 | 37/2.25 | 15.80 | 406.0 | 25.3 | 0.1960 |
| 185 | 181.6 | 37/2.50 | 17.50 | 500.0 | 30.5 | 0.1588 |
| 240 | 242.5 | 61/2.25 | 20.30 | 670.0 | 39.5 | 0.1191 |
| 300 | 299.4 | 61/2.50 | 22.50 | 827.0 | 47.7 | 0.0965 |
| 400 | 400.1 | 61/2.89 | 26.00 | 1104.0 | 60.9 | 0.0722 |
| 500 | 499.8 | 61/3.23 | 29.10 | 1379.0 | 74.7 | 0.0578 |
| 625 | 626.2 | 91/2.96 | 32.60 | 1732.0 | 95.3 | 0.0462 |
| 800 | 802.1 | 91/3.35 | 36.90 | 2218.0 | 118.4 | 0.0360 |
| 1000 | 999.7 | 91/3.74 | 41.10 | 2767.0 | 145.8 | 0.0289 |
AS 1531
| Code Name |
Nominal Area |
No. & Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
| mm2 | No./mm | mm | kg/km | kN | Ω/km | |
| Leo | 34.4 | 7/2.50 | 7.50 | 94.3 | 5.7 | 0.8330 |
| Leonids | 41.6 | 7/2.75 | 8.25 | 113.0 | 6.7 | 0.6890 |
| Libra | 49.5 | 7/3.00 | 9.00 | 135.0 | 8.0 | 0.5790 |
| Mars | 77.3 | 7/3.75 | 11.30 | 211.0 | 11.8 | 0.3700 |
| Mercury | 111.0 | 7/4.50 | 13.50 | 304.0 | 16.9 | 0.2580 |
| Moon | 124.0 | 7/4.75 | 14.30 | 339.0 | 18.9 | 0.2320 |
| Neptune | 158.0 | 19/3.25 | 16.30 | 433.0 | 24.7 | 0.1830 |
| Orion | 183.0 | 19/3.50 | 17.50 | 503.0 | 28.7 | 0.1570 |
| Pluto | 210.0 | 19/3.75 | 18.80 | 576.0 | 31.9 | 0.1370 |
| Saturn | 262.0 | 37/3.00 | 21.00 | 721.0 | 42.2 | 0.1100 |
| Sirius | 307.0 | 37/3.25 | 22.80 | 845.0 | 48.2 | 0.0940 |
| Taurus | 337.0 | 19/4.75 | 23.80 | 924.0 | 51.3 | 0.0857 |
| Triton | 409.0 | 37/3.75 | 26.30 | 1120.0 | 62.2 | 0.0706 |
| Uranus | 506.0 | 61/3.25 | 29.30 | 1400.0 | 75.2 | 0.0572 |
| Ursula | 587.0 | 61/3.50 | 31.50 | 1620.0 | 87.3 | 0.0493 |
| Venus | 673.0 | 61/3.75 | 33.80 | 1860.0 | 97.2 | 0.0429 |
BS EN 50182
| Code Name |
No.& Dia. of Wire | Approx. Overall Dia. |
Total Area |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
| No./mm | mm | mm2 | kg/km | kN | Ω/km | |
| Gnat | 7/2.21 | 6.63 | 26.9 | 73.0 | 4.8 | 1.0643 |
| Mosquito | 7/2.59 | 7.77 | 36.9 | 101.0 | 6.3 | 0.7749 |
| Ladybird | 7/2.79 | 8.37 | 42.8 | 117.0 | 7.3 | 0.6678 |
| Bluebottle | 7/3.66 | 10.98 | 73.6 | 201.0 | 11.8 | 0.3880 |
| Earwig | 7/3.78 | 11.34 | 78.6 | 215.0 | 12.6 | 0.3638 |
| Grasshopper | 7/3.91 | 11.73 | 84.1 | 230.0 | 13.5 | 0.3400 |
| Clegg | 7/4.17 | 12.51 | 95.6 | 261.0 | 15.3 | 0.2989 |
| Beetle | 19/2.67 | 13.35 | 106.4 | 292.0 | 18.1 | 0.2701 |
| Bee | 7/4.90 | 14.70 | 132 | 361.0 | 21.1 | 0.2165 |
| Caterpillar | 19/3.53 | 17.65 | 185.9 | 511.0 | 29.8 | 0.1546 |
| Spider | 19/3.99 | 19.95 | 237.6 | 653.0 | 38.0 | 0.1210 |
| Moth | 19/5.00 | 25.00 | 373.1 | 1025.0 | 59.7 | 0.0770 |
| Drone | 37/3.58 | 25.06 | 372.4 | 1027.0 | 59.6 | 0.0774 |
| Maybug | 37/4.09 | 28.63 | 486.1 | 1341.0 | 77.8 | 0.0593 |
| Scorpion | 37/4.27 | 29.89 | 529.8 | 1461.0 | 84.8 | 0.0544 |
| Cicada | 37/4.65 | 32.55 | 628.3 | 1733.0 | 100.5 | 0.0459 |
ASTM B231
| Code Name |
Nominal Area | No./ Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
|
| AWG or MCM | mm2 | No./mm | mm | kg/km | kN | Ω/km | |
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6.0 | 0.8567 |
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
| Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
| Aster | 2/0.0 | 67.4 | 7/3.50 | 10.50 | 185.7 | 11.1 | 0.4267 |
| Phlox | 3/0.0 | 85.0 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
| Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17.0 | 0.2675 |
| Valerian | 250.0 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
| Sneezewort | 250.0 | 126.7 | 7/4.80 | 14.40 | 348.8 | 20.1 | 0.2269 |
| Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
| Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
| Peony | 300.0 | 152.0 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.90 | 469.5 | 27.3 | 0.1686 |
| Daffodil | 350.0 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
| Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.1430 |
| Goldentuft | 450.0 | 228.0 | 19/3.91 | 19.55 | 627.6 | 35.0 | 0.1260 |
| Syringa | 477.0 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
| Cosmos | 477.0 | 241.7 | 19/4.02 | 20.10 | 664.8 | 37.0 | 0.1192 |
| Hyacinth | 500.0 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
| Zinnia | 500.0 | 253.3 | 19/4.12 | 20.60 | 697.1 | 38.9 | 0.1134 |
| Dahlia | 556.5 | 282.0 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
| Mistletoe | 556.5 | 282.0 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
| Meadowsweet | 600.0 | 304.0 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
| Orchid | 636.0 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
| Heuchera | 650.0 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
| Flag | 700.0 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
| Varbena | 700.0 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
| Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
| Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
| Cattail | 750.0 | 380.0 | 61/2.82 | 25.38 | 1046.0 | 60.3 | 0.0754 |
| Petunia | 750.0 | 380.0 | 37/3.62 | 25.34 | 1046.0 | 58.6 | 0.0755 |
| Lilac | 795.0 | 402.8 | 61/2.90 | 26.10 | 1110.0 | 63.8 | 0.0713 |
| Arbutus | 795.0 | 402.8 | 37/3.72 | 26.04 | 1109.0 | 61.8 | 0.0715 |
| Snapdragon | 900.0 | 456.0 | 61/3.09 | 27.81 | 1256.0 | 70.8 | 0.0628 |
| Cockscomb | 900.0 | 456.0 | 37/3.96 | 27.72 | 1256.0 | 68.4 | 0.0631 |
| Goldenrod | 954.0 | 483.4 | 61/3.18 | 28.62 | 1331.0 | 75.0 | 0.0593 |
| Magnolia | 954.0 | 483.4 | 37/4.08 | 28.56 | 1331.0 | 72.6 | 0.0594 |
| Camellia | 1000.0 | 506.7 | 61/3.25 | 29.25 | 1394.0 | 78.3 | 0.0568 |
| Hawkweed | 1000.0 | 506.7 | 37/4.18 | 29.26 | 1395.0 | 76.2 | 0.0566 |
| Larkspur | 1033.5 | 523.7 | 61/3.31 | 29.79 | 1442.0 | 81.3 | 0.0547 |
| Bluebell | 1033.5 | 523.7 | 37/4.25 | 29.75 | 1441.0 | 78.8 | 0.0547 |
| Marigold | 1113.0 | 564.0 | 61/3.43 | 30.87 | 1553.0 | 87.3 | 0.0510 |
| Hawthorn | 1192.5 | 604.2 | 61/3.55 | 31.95 | 1662.0 | 93.5 | 0.0476 |
| Narsissus | 1272.0 | 644.5 | 61/3.67 | 33.03 | 1774.0 | 98.1 | 0.0445 |
| Columbine | 1351.0 | 694.8 | 61/3.78 | 34.02 | 1884.0 | 104.0 | 0.0420 |
| Carnation | 1431.0 | 725.1 | 61/3.89 | 35.01 | 1997.0 | 108.0 | 0.0396 |
| Gladiolus | 1510.5 | 765.4 | 61/4.00 | 36.00 | 2108.0 | 114.0 | 0.0375 |
| Coreopsis | 1590.0 | 805.7 | 61/4.10 | 36.90 | 2216.0 | 120.0 | 0.0357 |
| Jassamine | 1750.0 | 886.7 | 61/4.30 | 38.70 | 2442.0 | 132.0 | 0.0324 |
| Cowslip | 2000.0 | 1013.0 | 91/3.77 | 41.47 | 2787.0 | 153.0 | 0.0286 |
| Sagebrush | 2250.0 | 1140.0 | 91/3.99 | 43.89 | 3166.0 | 167.0 | 0.0255 |
| Lupine | 2500.0 | 1267.0 | 91/4.21 | 46.31 | 3519.0 | 186.0 | 0.0229 |
| Bitterrot | 2750.0 | 1393.0 | 91/4.42 | 48.62 | 3872.0 | 205.0 | 0.0208 |
| Trillium | 3000.0 | 1520.0 | 127/3.90 | 50.70 | 4226.0 | 223.0 | 0.0193 |
| Bluebonnet | 3500.0 | 1773.0 | 127/4.22 | 54.86 | 4977.0 | 261.0 | 0.0165 |
GB/T 1179
| Nominal Area |
Total Area |
No./Dia. of Wire | Approx. Overall Dia. |
Approx. Weight |
Nominal Breaking Load |
Max. DC Resistance at 20°C |
| mm2 | mm2 | No./mm | mm | kg/km | kN | Ω/km |
| 35 | 34.4 | 7/2.50 | 7.50 | 94.0 | 6.0 | 0.8333 |
| 50 | 49.5 | 7/3.00 | 9.00 | 135.3 | 8.4 | 0.5787 |
| 70 | 71.3 | 7/3.60 | 10.80 | 194.9 | 11.4 | 0.4019 |
| 95 | 95.1 | 7/4.16 | 12.50 | 260.2 | 15.2 | 0.3010 |
| 120 | 121.2 | 19/2.85 | 14.30 | 333.2 | 20.6 | 0.2374 |
| 150 | 148.1 | 19/3.15 | 15.80 | 407.0 | 24.4 | 0.1943 |
| 185 | 182.8 | 19/3.50 | 17.50 | 502.4 | 30.2 | 0.1574 |
| 210 | 209.9 | 193.75 | 18.80 | 576.8 | 33.6 | 0.1371 |
| 240 | 238.8 | 19/4.00 | 20.00 | 656.3 | 38.2 | 0.1205 |
| 300 | 297.6 | 19/3.20 | 22.40 | 819.8 | 49.1 | 0.0969 |
| 500 | 502.9 | 19/4.16 | 29.10 | 1385.5 | 80.5 | 0.0573 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
- Raw material inspection and test
- Production process test
- Unqualified product control
- Regular test and examination
- Finished product inspection
UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s’ Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.
We are China Power Transmission Line Electrical Cable All Aluminum Conductor AAC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Products
Aluminum Conductor Steel Reinforced AAC AAAC ACSR Overhead Conductor
Almenec Cable 34, 4mm2 NF C 34-125
Overhead AAC Bare Conductor / Aluminum
Overhead Conductor AAC/AAAC/ACSR Bare Conductors
Stranded Aluminium Wire 1350 Series Aluminium Conductor AAC
All Aluminum Conductor AAC Cable
Popular AAC Conductor Products
BS215 Bare AAC All Aluminium Conductor Ant Wasp
ASTM Wholesale Bluebonnet Bare Conductor Aluminum Alloy Conductor AAC
AAC AAAC ACSR Steel Wire Bare Aluminum Overhead Conductor Manufacture
Overhead Transmission Line All Aluminum Conductor Bare AAC Conductor
54/6 mm2 Almelec Bare Cable ACSR/AAC/AAAC Conductor ACSR Bare Overhead Conductor
ASTM B231 61 Wire Strand 61*3.668mm 1272 Mcm Narcissus AAC All Aluminum Conductor
Popular Power Transmission Line Electrical Cable All Aluminum Conductor AAC Products
Popular umecable Products
0.6/1kv XLPE Insulation PVC Sheath Swa Cable
Accc Aluminum Conductor Composite Core Electrical Wire Aluminum Bare Cable Accc
Copper Conductor Fire Resistant Steel Tape Armored Power Cable
Tags: AAC, AAC Conductor, Power Transmission Line Electrical Cable All Aluminum Conductor AAC, umecable