Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable
Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer’s request.
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
Power cable are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
|
TYPE |
NAME |
Main Application |
|
|
CU core |
AL core |
|
|
|
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
|
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
|
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
|
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
| 1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
| 1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
| 1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
| 1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
| 1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
| 1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
| 1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
| 1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
| 1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
| 1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
| 1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
| 1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
| 1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
| 1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
| 1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
| 2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
| 2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
| 2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
| 2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
| 2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
| 2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
| 2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
| 2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
| 2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
| 2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
| 2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
| 2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
| 2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
| 2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
| 2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
| 2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
| 3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
| 3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
| 3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
| 3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
| 3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
| 3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
| 3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
| 3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
| 3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
| 3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
| 3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
| 3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
| 3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
| 3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
| 3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
| 3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
| mm² | mm | mm | mm | mm | mm | mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
| 3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
| 3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
| 3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
| 3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
| 3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
| 3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
| 3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
| 3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
| 3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
| 3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
| 4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
| 4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
| 4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
| 4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
| 4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
| 4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
| 4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
| 4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
| 4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
| 4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
| 4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
| 4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
| 4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
| 4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
| 4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
| 4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
We are China Price Low Voltage 4 Core 95mm XLPE/PVC Insualted Armoured Submarine Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 4 Core 95mm Power Cable Products
4 Core 95mm Power Cable Made in Jinshui
Low Voltage 0.6/1kv 4 Core 95mm Power Cable 4 Core 4 Sq mm Aluminium Cable Price
IEC/BS Standard 4 Core Power Cable From Shandong New Luxing Cable Factory
Copper Conductor XLPE Insulated 4 Core 95mm Power Cable
Top Quality 4 Core 95mm Power Cable Wire Electric
4 Core 95mm Power Cable for Underground Electric Cable
Popular Armoured Power Cable Size Products
Flame Retardant Submarine XLPE Insulated Armoured Power Cable Size
Armoured Power Cable 0.6/1kv 4 Core 150mm2 XLPE Insulated Steel Wire /Aluminum Cable
4 Cores 16mm Electric Cable Armoured Power Cable
IEC 60502 0.6/1kv Low Voltage Copper Conductor XLPE Insulated Armoured Cables
Underground Armoured Power Cable Cu XLPE Swa PVC Size 120mm 240mm XLPE 4 Core Armoured Cable
Yjv22 Yjv32 600V Copper Amour Power Cable
Popular jytopcable Products
7/4 mm Stay Wire Steel Stranded Guy Wire
XLPE Insulated Steel Tape Armoured Power Cable
H03VV-F, H05VV-F 3*1.5mm Copper Flexible PVC Insulated Electric Power Cable
High Voltage 18/30 (33) Kv Aluminum Conductor XLPE Insulated Steel Tape Armored Cable
High Quality ACSR Conductor Caa for Brazil
High Quality Guy Wire, Stay Wire, Gsw Wire for ASTM A475
Popular Submarine Power Cable Products
The High Quality Europe Market Epr Sheath Nsshou-O/J 802 Rubber Insulated Flexible Mining Cable
5kv Copper Conductor Epr Insulation Rubber Sheath Mining Cable
Flexible Rubber Sheath Multi-Core Mining Cable
UL1650 Type W 2kv 8AWG to 500mcm Copper Flexible Mining Cable Rubber Mine Cable
Hot Sale Hv Submarine Power Cable 33kv 35mm 70mm 95mm 240mm
Medium Voltage Rubber Mining Cable
Tags: 4 Core 95mm Power Cable, Armoured Power Cable Size, jytopcable, Submarine Power Cable