PVC Insulated and Sheathed Copper Cce Ccv Control Cable 0.6/1kv

China 
                        PVC Insulated and Sheathed Copper Cce Ccv Control Cable 0.6/1kv
                      manufacture and supplier

PVC Insulated and Sheathed Copper Cce Ccv Control Cable 0.6/1kv image

Get Latest Price Request a quote

Quick Details

PVC Insulated and Sheathed Copper Cce Ccv Control Cable 0.6/1kv

Control Cable

OEM

ISO9001, CE, CCC

Flame Retardant

Round Wire

PVC

PVC

Copper

Heating

Stranded

Insulated

OEM

Wooden Drum

1.5mm to 50mm2

China(Mainland)

8544492100

Product Details

Application:   Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.

Construction- Conductors:Annealed Copper Wire
– Insulation : PVC
– Core Identification : Coloring Method – below 4 cores
  (2 cores – Black, White /3 cores – Black, White, Red )
  Numbering Method (Above 5 cores)
– Sheath : PVC

Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS

3 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
3 0.5 7/0.30 0.8 1.8 10.0 36.0 0.0162 110 500/D
0.75 7/0.37 0.8 1.8 10.5 24.5 0.0142 125 500/D
1 7/0.40 0.8 1.8 11.0 18.1 0.0135 135 500/D
1.5 7/0.50 0.8 1.8 11.5 12.1 0.0115 160 500/D
2.5 7/0.67 0.8 1.8 13.0 7.41 0.0093 220 500/D
4 7/0.85 1.0 1.8 15.0 4.61 0.0092 315 500/D
6 7/1.04 1.0 1.8 16.5 3.08 0.0078 405 500/D

4 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
4 0.5 7/0.30 0.8 1.8 11.0 36.0 0.0162 130 500/D
0.75 7/0.37 0.8 1.8 11.5 24.5 0.0142 150 500/D
1 7/0.40 0.8 1.8 11.5 18.1 0.0135 160 500/D
1.5 7/0.50 0.8 1.8 12.5 12.1 0.0115 195 500/D
2.5 7/0.67 0.8 1.8 14.0 7.41 0.0093 265 500/D
4 7/0.85 1.0 1.8 16.5 4.61 0.0092 390 500/D
6 7/1.04 1.0 1.8 17.0 3.08 0.0078 510 500/D

5 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
5 0.5 7/0.30 0.8 1.8 11.5 36.0 0.0162 150 500/D
0.75 7/0.37 0.8 1.8 12.5 24.5 0.0142 175 500/D
1 7/0.40 0.8 1.8 12.5 18.1 0.0135 190 500/D
1.5 7/0.50 0.8 1.8 13.5 12.1 0.0115 230 500/D
2.5 7/0.67 0.8 1.8 15.0 7.41 0.0093 320 500/D
4 7/0.85 1.0 1.8 18.0 4.61 0.0092 470 500/D
6 7/1.04 1.0 1.8 19.5 3.08 0.0078 620 500/D

6 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
6 0.5 7/0.30 0.8 1.8 12.5 36.0 0.0162 165 500/D
0.75 7/0.37 0.8 1.8 13.0 24.5 0.0142 190 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 205 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 255 500/D
2.5 7/0.67 0.8 1.8 16.0 7.41 0.0093 355 500/D
4 7/0.85 1.0 1.8 19.5 4.61 0.0092 525 500/D
6 7/1.04 1.0 1.8 21.0 3.08 0.0078 690 500/D

7 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
7 0.5 7/0.30 0.8 1.8 12.5 36.0 0.0162 170 500/D
0.75 7/0.37 0.8 1.8 13.0 24.5 0.0142 200 500/D
1 7/0.40 0.8 1.8 13.5 18.1 0.0135 215 500/D
1.5 7/0.50 0.8 1.8 14.5 12.1 0.0115 270 500/D
2.5 7/0.67 0.8 1.8 16.0 7.41 0.0093 380 500/D
4 7/0.85 1.0 1.8 19.5 4.61 0.0092 570 500/D
6 7/1.04 1.0 1.8 21.0 3.08 0.0078 795 500/D

8 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia.
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
8 0.5 7/0.30 0.8 1.8 13.5 36.0 0.0162 195 500/D
0.75 7/0.37 0.8 1.8 14.0 24.5 0.0142 230 500/D
1 7/0.40 0.8 1.8 14.5 18.1 0.0135 250 500/D
1.5 7/0.50 0.8 1.8 15.5 12.1 0.0115 310 500/D
2.5 7/0.67 0.8 1.8 17.5 7.41 0.0093 440 500/D
4 7/0.85 1.0 1.8 21.0 4.61 0.0092 660 500/D
6 7/1.04 1.0 1.8 23.0 3.08 0.0078 875 500/D

9 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
9 0.5 7/0.30 0.8 1.8 14.0 36.0 0.0162 220 500/D
0.75 7/0.37 0.8 1.8 15.0 24.5 0.0142 265 500/D
1 7/0.40 0.8 1.8 15.5 18.1 0.0135 285 500/D
1.5 7/0.50 0.8 1.8 16.5 12.1 0.0115 355 500/D
2.5 7/0.67 0.8 1.8 18.5 7.41 0.0093 505 500/D
4 7/0.85 1.0 1.8 22.5 4.61 0.0092 760 500/D
6 7/1.04 1.0 1.8 24.5 3.08 0.0078 1015 500/D

10 Core CVV Control Cable

No. of core Nominal 
cross- 
sectional area 
sq.mm
No.& dia. 
of wires No./mm
Thickness
of insulation mm
Thickness
of sheath 
mm
Overall diameter (Approx.) 
mm
Maximum conductor resistance 
(at20C) 
Ohm/km
Minimum insulation resistance 
(at70C) 
Ohm/km
Cable 
weight (Approx.) kg/km
Standard Length 
m
10 0.5 7/0.30 0.8 1.8 15.5 36.0 0.0162 240 500/D
0.75 7/0.37 0.8 1.8 16.0 24.5 0.0142 285 500/D
1 7/0.40 0.8 1.8 16.5 18.1 0.0135 310 500/D
1.5 7/0.50 0.8 1.8 18.0 12.1 0.0115 385 500/D
2.5 7/0.67 0.8 1.8 20.0 7.41 0.0093 550 500/D
4 7/0.85 1.0 1.8 24.5 4.61 0.0092 825 500/D
6 7/1.04 1.0 1.8 27.0 3.08 0.0078 1100 500/D

 Packing shipping

  

Why Choose Us ?
1. We have a large production base, and advanced production equipment 
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas

Any problem and inquiry pls contact with Tina
Phone number: +86-15737156317

We are China PVC Insulated and Sheathed Copper Cce Ccv Control Cable 0.6/1kv manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Cce Control Cable Products

  • No related articles
  • Popular Ccv Cable Products

  • No related articles
  • Popular Ccv Control Cable Products

  • No related articles
  • Popular zzhongdacable Products

    U1000 R2V RO2V Ar2V Rvfv 0.6/1kv Cu/XLPE/PVC Power Cable

    6mm 10mm 16mm 25mm 4 Core Galvanized Steel Wire Swa Armoured Copper Cable

    LV&Mv Cu/Al Conductor XLPE/PVC Insulated Power Cable

    Na2xs (FL) 2y 6/10 (12) Kv Cable Tender Project Cable

    Aerial Bunched XLPE Aluminum Cables 2X10, 2X16 Sqmm ABC Cable

    Vhov-K (PAR-POS) Vov-K (POS) 300/500 V Cable 1.0 1.5 2.5

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION