PVC Insulated Copper Conductor Building Wires

China 
                        PVC Insulated Copper Conductor Building Wires
                      manufacture and supplier

PVC Insulated Copper Conductor Building Wires image

Get Latest Price Request a quote

Quick Details

PVC Insulated Copper Conductor Building Wires

Building Wire

Rmjt

ISO9001, CCC

Flame Retardant

Flat Wire

PVC

PVC

Copper

Heating

Solid or Strand

Insulated

Copper Core PVC Coated Wire Electrical Wire for Ho

Single, 2, 3 or 4 Cores

GB 5023.1~7-1997 IEC 60227

ISO9001-2008, ISO14001-2004, CCC, SGS, BV etc

BV, Blv, BVV, Blvv, BVVB, Blvvb, RV, Rvb, Rvs, Rvv

300/300V, 450/750V

Packing in Rolls or as Your Requirement

L/C, D/a, D/P, T/T, Western Union, Moneygram

High Quality, Competitive Price, Fast Delivery

RMJT

Package in Rolls or as Your Request

1.5mm2-400mm2

Henan, China

8544492100

Product Details

PVC Insulated Copper Conductor Building Wires

Description
Electric wire: Copper or aluminum conductor, pvc insulated wire
Electric wire: THW wire, the cable, H07V-U, H05V-U,H07V-R
The conductor type of electric wire: Solid core and stranded core
Cores of electric wire: single core, two cores, three cores

Section area of electric wire
300/500v:0.5mm2,0.75mm2m1.0mm2 
450/750v 1.5mm2,2.5mm2,4mm2,6mm2,10mm2,16mm2,25mm2,35mm2,50mm2,70mm2,95mm2,
120mm2,150mm2,185mm2,240mm2,300mm2m400mm2
300/500v; 2×0.75, 2×1.0, 2×1.5, 2×2.5, 2×4, 5×6, 2×10, 3×0.75, 3×1, 3×1.5, 3×2.5, 3×4, 3×6, 3x10mm2

 

Application
PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or less

Specification
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.

H07V-U Specification

450/750V,Copper Conductor PVC Insulated Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 1.5 1 1.38 0.7 2.78 19.7
1 X2.5 1 1.78 0.8 3.38 31.2
1 X4.0 1 2.25 0.8 3.85 46.1
1 X6.0 1 2.76 0.8 4.36 65.7
1 X10 1 3.55 1.0 5.55 108.0
450/750V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90ºC
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 0.5 1 0.8 0.6 2.00 8.16
1 X 0.75 1 0.97 0.6 2.17 10.71
1 X 1.0 1 1.13 0.6 2.33 13.48
1 X 1.5 1 1.38 0.7 2.78 19.70
1 X 2.5 1 1.78 0.8 3.38 31.20

H07V-R Specification

450/750V,Copper Conductor PVC Insulated Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 1.5 7 0.52 0.7 2.96 20.4
1 X2.5 7 0.67 0.8 3.61 32.3
1 X4.0 7 0.85 0.8 4.15 47.8
1 X6.0 7 1.04 0.8 4.72 67.7
1 X10 7 1.35 1.0 6.05 113.1
1 X 16 7 1.70 1.0 7.1 170.9
1 X 25 7 2.14 1.2 8.82 268.5
1 X 35 7 2.52 1.2 9.96 362.8
1 X 50 19 1.78 1.4 11.7 492.2
1 X 70 19 2.14 1.4 13.5 694.2
1 X 95 19 2.52 1.6 15.8 959.2
1 X 120 37 2.03 1.6 17.41 1197.1
1 X 150 37 2.25 1.8 19.35 1472.9
1 X 185 37 2.52 2.0 21.64 1846.1
1 X 240 61 2.25 2.2 24.65 2416.5
1 X 300 61 2.52 2.4 27.48 3023.6
1 X 400 61 2.85 2.6 30.85 3851.7

H07V-K Specification

450/750V,Copper Conductor PVC Insulated Flexible Wire
Nominal Cross Section Conductor Construction Insulation Thickness Overall Diameter Approx. Net Weight
mm2 No. Diameter mm mm kg/km
1 X 1.5 30 0.25 0.7 3.00 20.6
1 X2.5 49 025 0.8 3.70 32.2
1 X4.0 56 0.30 0.8 4.21 48.
1 X6.0 84 0.30 0.8 5.57 71.2
1 X10 84 0.40 1.0 7.30 124.4
1 X 16 126 0.40 1.0 8.00 175.8
1 X 25 196 0.40 1.2 10.10 272.5
1 X 35 276 0.40 1.2 11.87 373.9
1 X 50 396 0.40 1.4 13.93 532.8
1 X 70 360 0.50 1.4 16.12 737.9
1 X 95 475 0.50 1.6 19.24 978.1
1 X 120 608 0.50 1.6 19.95 1222.5
1 X 150 756 0.50 1.8 23.34 1529.7
1 X 185 925 0.50 2.0 25.54 1870.1
1 X 240 1221 0.50 2.2 27.85 2443.4
1 X 300 1525 0.50 2.4 32.49 3032.9
1 X 400 2013 0.50 2.6 35.35 3958.6

HO3VV-F and AO3VV-F Specification

Rated Voltage Copper Conductor PVC Insulated PVC Sheathed Round Flexible Connecting Wire
Nominal Cross Section Conductor Construction Insulation Thickness PP Tape Sheath Thickness Overall Diameter Approx. Net Weight
mm2 No./mm mm No./mm mm mm kg/km
300/300V 2 X0.5 16/0.20 0.5 1/0.05 0.6 5.87 34.80
2 X 0.75 24/0.20 0.5 1/0.05 0.6 6.50 43.40
3 X 0.5 16/0.20 0.5 1/0.05 0.6 6.22 44.01
3 X 0.75 24/0.20 0.5 1/0.05 0.6 6.90 55.64
300/500V 2 X 0.5 16/0.20 0.6 1/0.05 0.7 5.78 36.69
2 X 0.75 24/0.20 0.6 1/0.05 0.8 6.78 47.02
2 X 1.0 32/0.20 0.6 1/0.05 0.8 6.78 54.79
2 X 1.5 30/0.25 0.7 1/0.05 0.8 7.71 72.31
2 X 2.5 49/0.25 0.8 1/0.05 0.8 9.51 111.90
3 X 0.5 16/0.20 0.6 1/0.05 0.7 6.11 46.72
3 X 0.75 24/0.20 0.6 1/0.05 0.8 6.74 59.71
3 X 1.0 32/0.20 0.6 1/0.05 0.8 7.17 71.03
3 X 1.5 30/0.25 0.7 1/0.05 0.8 8.17 95.26
3 X 2.5 49/0.25 0.8 1/0.05 1.2 10.48 156.81
3 X 4.0 50/0.30 0.8 1/0.05 1.2 11.38 199.81
4 X 1.0 32 X 0.20          
4 X 1.5 48 X 0.20          
4 X 2.5 77 X 0.20          
4 X 4.0 56 X 0.30          
4 X 6.0 84 X 0.30          
4 X 10 84 X 0.40          
4 X 16 126 X 0.40          
5 X 1.5 48 X 0.20          
5 X 2.5 77 X 0.20          
5 X 4.0 56 X 0.30          
5 X 6.0 84 X 0.30          
5 X 10 84 X 0.40          
5 X 16 126 X 0.40          

H03VVH2-F Specification

300/500V,Copper Conductor PVC Insulated PVC Sheathed Flat Wire
Nominal Cross Section Conductor Construction Insulation Thickness Sheath Thickness Overall Diameter Approx. Net Weight
mm2 No./mm mm mm mm x mm kg/km
2 X 0.75 1/0.97 0.6 0.9 3.97 x 6.14 39.0
2 X 1.0 1/1.13 0.6 0.9 4.13 x6.46 45.6
2 X1.5 1/1.37 0.7 0.9 4.57×7.34 60.5
2 X2.5 1/1.76 0.8 1.0 5.36×8.72 89.9
2 X4 1/2.24 0.8 1.0 5.84×9.68 123.5
2 X4 7/0.85 0.8 1.0 6.15×10.30 130.6
2 X6 1/2.74 0.8 1.1 6.54×10.88 169.4
2 X6 7/1.04 0.8 1.1 6.92×11.64 179.2
2 X10 7/1.35 1.0 1.2 9.45×14.50 286.5
2 X16 7/1.70 1.0 1.2 9.50×16.60 412.3
3 X0.75 1/0.97 0.6 0.9 3.97×8.31 55.2
3 X1.0 1/1.13 0.6 0.9 4.13×8.79 65.0
3 X1.5 1/1.38 0.7 0.9 4.58×10.14 87.7
3 X2.5 1/1.76 0.8 1.0 5.36×12.08 129.9
3 X4 1/2.24 0.8 1.1 6.04×13.72 184.7
3 X 4 7/0.85 0.8 1.1 6.35×14.65 195.4
3 X6 1/2.74 0.8 1.1 6.54×15.22 247.7
3 X 6 7/1.04 0.8 1.1 6.92×16.36 262.0
3 X10 7/1.35 1.0 1.2 8.45×20.55 420.8

Products details

Packing and Delivery

Our Company

 

FAQ and contact information

Q: Do you accept customize?
A: Yes, we have our own factory, all communication cables are customized. 
Q: Can you print our logo or company name? 
A: Yes, we could print your logo or company name on our products.
Q: Can you design for us? 
A: Yes, we have professional designer, please tell us your requirement, let us do it for you. 
Q: Is it possible to get a free sample?
A: Yes, stock samples are free, but shipping cost you collect. We could also customize sample for you,the specific price will be confirmed according to the sample’s workmanship.If we have a further cooperation in the future, the sample fee will be returned. 
Q: What is your MOQ?
A: Usually, MOQ of communication cable is 1,000 meter, MOQ of rf connector is 500 pcs. But depend on the different material, size and workmanship, the MOQ will be changed. 
Q: How long can we receive your quotation? 
A: If your information is very detail, quotation will be offered within 6 hours. In order to receive our quotation as soon as possible, please give us following information: 
1) Type; 2) Size; 3) Specification; 4) Quantity. 
If it is possible, please also provide with pictures or design for checking. Sample will be best for clarifying. 
Q: Do you have a range of stock items for sale? 
A: We have enough neutral storage for hot-selling items. 
Q: What is your delivery time?
A: Usually 7-10 days. According to the product and quantity, delivery time will have different.

Ivan Fan | Sales Manager | People’s Cable Group
 
 
 
Web: renmincable.en. 

For more information, please kindly contact us freely! 
Welcome your inquiry of building wires and cables, please kindly inform us the section area, material, application, quantity you needed, so that we could quote accordingly

We are China PVC Insulated Copper Conductor Building Wires manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Electrical Wire Products

Price H03vvh2-F Copper Electric Wire PVC Flat Electrical Wire

LV 600V PVC Insulated Flexible Green/Yellow 35mm 50mm 70mm Earth Wire AS/NZS5000.1

PVC Insulated Flexible Building Electric Wire IEC Standard

High Quality XLPE Power Cable 0.6/1kv

Building Electricity transmission PVC Insulated Wire

High Quality Electrical Building Wire

Popular PVC Coated Wire Products

Single Core PVC Insulated Solid Copper H07V-U 1.5mm2 2.5mm2 Electrical Wire Cable

Customized 2.5mm Electric Cable PVC Coated Wire

Copper Core PVC Coated Wire Electrical Wire for House Using

Solid Copper Conductor PVC Coated Electric Cable Building Wire

1.5mm2 2.5mm2 Copper Core PVC Coated Electrical Building House Wire

450/750V Copper Core PVC Coated Electric Building Wire Cable

Popular renmincable Products

UL 3122 Fiberglass Braid Silicone Rubber Heat Resisting Cable/Wire

Overhead Aluminum Conductor XLPE Insulation PVC Sheath Amoured Power Cable

People's Cable Group Aluminium Alloy Conductor Steel Reinforced Aacsr

High Quality Copper Conductor Electric Cable Control Cable

PVC Insulated PVC Sheath Felxible Cable /Rvv Cable

0.6/1kv PV1-F XLPE Insulated Class 5 Flexible Tinned Copper Solar Panels AC DC Photovoltaic Wire Solar PV Cable

Popular Wire Products

BS Standard All Aluminum Conductor 150mm AAC Conductor

XLPE Insulated Power Electric Cable

Liycy Cable Liyy Cable 5mm Copper Wire

10kv 15kv 35kv Copper or Aluminum Cable for Underground Use

795 Mcm ACSR Conductor Aluminum

Factory Price 3 Core 0.75mm2 1.5mm2 2.5mm2 Flexible Wire

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION