PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2

China 
                        PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2
                      manufacture and supplier

PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2 image

Get Latest Price Request a quote

Quick Details

PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2

Zhonghua

CE, CCC

Electrical Device/Domestic Appliance, etc

Round Wire

PVC

None

Electrical Device/Domestic Appliance, etc

Solid

Insulated

Black, Red, Yellow, Blue, White

ZHONGHUA

Roll in

1.5-400mm2

Hubei, Wuhan

8544110000

Product Details

450/750V Copper Core PVC Insulated Electric Wire 

Application 
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of  flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.

Pruduct Structure

Reference Data of the Product Structure:  IEC 60227
1. 01(BV)Cable

Nominal Section
of the conductor
(mm2)
Conductor Types Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(/km)
Minumum Insulation Resistance at 70ºC
(M·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BV Minimum Maximum BV
1.5 1 2.82 2.6 3.2 19.70 12.1 0.011 18
1.5 2 3.00 2.7 3.3 20.31 12.1 0.010 18
2.5 1 3.43 3.2 3.9 31.20 7.41 0.010 25
2.5 2 3.69 3.3 4.0 32.82 7.41 0.009 25
4 1 3.90 3.6 4.4 46.08 4.61 0.0085 33
4 2 4.20 3.8 4.6 47.45 4.61 0.0077 33
6 1 4.41 4.1 5.0 65.71 3.08 0.0070 42
6 2 4.77 4.3 5.2 67.19 3.08 0.0065 42
10 1 5.65 5.3 6.4 109.09 1.83 0.0070 58
10 2 6.13 5.6 6.7 113.07 1.83 0.0065 58
16 2 7.18 6.4 7.8 170.90 1.15 0.0050 78
25 2 8.92 8.1 9.7 268.52 0.727 0.0050 105
35 2 10.06 9.0 10.9 362.82 0.524 0.0043 130
50 2 11.81 10.6 12.8 492.15 0.387 0.0043 155
70 2 13.61 12.1 14.6 694.19 0.268 0.0035 200
95 2 15.93 14.1 17.1 959.23 0.193 0.0035 250
120 2 17.54 15.6 18.8 1197.15 0.153 0.0032 290
150 2 19.49 17.3 20.9 1472.95 0.124 0.0032 335
185 2 21.80 19.3 23.3 1846.14 0.0991 0.0032 390
240 2 24.83 22.0 26.6 2416.54 0.0754 0.0032 470
300 2 27.67 24.5 29.6 3023.55 0.0601 0.0030 540
400 2 31.06 27.5 33.2 3851.72 0.0470 0.0028 635

 
2.02(RV)Cable

Nominal Section
of the conductor
(mm2)
Conductor Types Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
RV Minimum Maximum RV
1.5 5 3.00 2.8 3.4 20.30 13.3 0.010 18
2.5 5 3.64 3.4 4.1 31.59 7.98 0.009 25
4 5 4.21 3.9 4.8 47.54 4.95 0.0070 33
6 5 4.81 4.4 5.3 67.42 3.3 0.0060 42
10 5 6.28 5.7 6.8 118.00 1.81 0.0056 58
16 5 7.20 6.7 8.1 169.44 1.21 0.0046 78
25 5 10.10 8.4 10.2 269.71 0.78 0.0044 105
35 5 11.23 9.7 11.7 364.35 0.554 0.0038 130
50 5 13.75 11.5 13.9 522.86 0.386 0.0037 155
70 5 15.40 13.2 16.0 720.89 0.272 0.0032 200
95 5 18.15 15.1 18.2 953.89 0.206 0.0032 250
120 5 19.70 16.7 20.2 1199.28 0.161 0.0029 290
150 5 21.10 18.6 22.5 1485.62 0.129 0.0029 335
185 5 24.03 20.6 24.9 1824.52 0.106 0.0029 390
240 5 26.70 23.5 28.4 2389.69 0.0801 0.0028 470

 
3.05(BV)Cable

Nominal Section
of the conductor
(mm2)
Conductor Types Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BV Minimum Maximum BV
0.5 1 2.04 1.9 2.3 8.16 36.0 0.015 9
0.75 1 2.21 2.1 2.5 10.71 24.5 0.012 12
1 1 2.37 2.2 2.7 13.48 18.1 0.011 14

 
4.06(RV)Cable

Nominal Section
of the conductor
(mm2)
Conductor Types Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
RV Minimum Maximum RV
0.5 5 2.18 2.1 2.5 8.58 39.0 0.013 9
0.75 5 2.43 2.2 2.7 11.50 26.0 0.011 12
1 5 2.52 2.4 2.8 14.00 19.5 0.010 14

 
5.10(BVV)Cable

Core No.×Nominal Section
of the conductor
(mm2)
Conductor Types Cable Reference Diameter
(mm)
Cable Average Diameter
(mm)
Cable Reference Weight
(kg/km)
Maximum Resistance of the conductor at 20ºC
(Ω/km)
Minumum Insulation Resistance at 70ºC
(MΩ·km)
Reference Current
(Ambient temperature is 40ºC,highest temperature is 70ºC)
(A)
BVV Minimum Maximum BVV
2×1.5 1 9.36 7.6 10.0 98.94 12.1 0.011 18
2×1.5 2 9.72 7.8 10.5 103.09 12.1 0.010 18
2×2.5 1 10.56 8.6 11.5 130.99 7.41 0.010 25
2×2.5 2 11.08 9.0 12.0 138.55 7.41 0.009 25
2×4 1 11.50 9.6 12.5 171.31 4.61 0.0085 33
2×4 2 12.10 10.0 13.0 179.24 4.61 0.0077 33
2×6 1 12.52 10.5 13.5 218.41 3.08 0.0070 42
2×6 2 13.24 11.0 14.0 227.77 3.08 0.0065 42
2×10 1 15.64 13.0 16.5 361.55 1.83 0.0070 65
2×10 2 16.70 13.5 17.5 384.71 1.83 0.0065 65
2×16 2 18.80 15.5 20.0 532.01 1.15 0.0052 87
2×25 2 22.64 18.5 24.0 798.61 0.727 0.0050 110
2×35 2 25.72 21.0 27.5 1055.97 0.524 0.0044 140
3×1.5 1 9.8 8.0 10.5 124.61 12.1 0.011 15
3×1.5 2 10.19 8.2 11.0 129.71 12.1 0.010 15
3×2.5 1 11.10 9.2 12.0 168.94 7.41 0.010 21
3×2.5 2 11.66 9.4 12.5 178.67 7.41 0.009 21
3×4 1 12.12 10.0 13.0 228.20 4.61 0.0085 28
3×4 2 12.76 10.5 13.5 238.21 4.61 0.0077 28
3×6 1 13.62 11.5 14.5 307.47 3.08 0.0070 36
3×6 2 14.40 12.0 15.5 319.96 3.08 0.0065 36
3×10 1 16.52 14.0 17.5 476.74 1.83 0.0070 56
3×10 2 17.67 14.5 19.0 507.40 1.83 0.0065 56
3×16 2 20.34 16.5 21.5 726.41 1.15 0.0052 74
3×25 2 24.05 20.5 26.0 1074.22 0.727 0.0050 98
3×35 2 27.31 22.0 29.0 1431.17 0.524 0.0044 120
4×1.5 1 10.51 8.6 11.5 159.43 12.1 0.011 15
4×1.5 2 10.95 9.0 12.0 165.62 12.1 0.010 15
4×2.5 1 11.96 10.0 13.0 216.48 7.41 0.010 21
4×2.5 2 12.59 10.0 13.5 228.55 7.41 0.009 21
4×4 1 13.49 11.5 14.4 296.50 4.61 0.0085 28
4×4 2 14.22 12.0 15.0 309.46 4.61 0.0077 28
4×6 1 15.13 12.5 16.0 398.92 3.08 0.0070 36
4×6 2 15.99 13.0 17.0 414.94 3.08 0.0065 36
4×10 1 17.93 15.5 19.0 594.97 1.83 0.0070 56
4×10 2 19.20 16.0 20.5 633.59 1.83 0.0065 56
4×16 2 22.14 18.0 35.5 916.62 1.15 0.0052 74
4×25 2 27.09 22.5 28.5 1414.08 0.727 0.0050 98
4×35 2 28.84 24.5 32.0 1826.39 0.524 0.0044 120
5×1.5 1 11.31 9.4 12.0 191.08 12.1 0.011 15
5×1.5 2 11.79 9.8 12.5 198.39 12.1 0.010 15
5×2.5 1 12.93 11.0 14.0 260.97 7.41 0.010 21
5×2.5 2 13.63 11.0 14.5 275.46 7.41 0.009 21
5×4 1 15.00 12.5 16.0 370.96 4.61 0.0085 28
5×4 2 15.81 13.0 17.0 387.08 4.61 0.0077 28
5×6 1 16.37 13.5 17.5 482.44 3.08 0.0070 36
5×6 2 17.34 14.5 18.5 501.42 3.08 0.0065 36
5×10 1 19.50 17.0 21.0 725.11 1.83 0.0070 56
5×10 2 20.94 17.5 22.0 771.84 1.83 0.0065 56
5×16 2 24.57 20.5 26.0 1142.09 1.15 0.0052 74
5×25 2 29.61 24.5 31,5 1732.02 0.727 0.0050 98
5×35 2 33.09 27.0 35.0 2272.06 0.524 0.0044 120

Notes: Conductor Types–1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
     which are suitable for different applications.

We are China PVC Insulated Copper Conductor Electric Building Wire Cable 1.5mm2 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 450/750V Cable Products

1.5 2.5mm2 4sqmm H07V-R 450/750V House Building Electric Wire Cable

PVC Insulated Single Solid Copper Core Plastic Electrical Cabl Wire 450V/750V BV 1.5 2.5 4 6 10 Sq mm Flexible 2.5mm2 4mm2

Rated Voltage 450/750 V and Below PVC Insulation and Flexible Cable

Plastic Insulation Control Cable 300/500V

UL1283 Tinned Bare Cooper Conductor PVC Insulation Underwater Electrical Cable

Cooper Core PVC Insulated Wire with Custom Color

Popular Cable Products

061kv Yjv Yjv22 3X50mm2 120mm2 Copper Low Voltage 240mm XLPE 4 Core Armoured Cable

Stay Wire ASTM Standard 7/32inch Galvanized Steel Wire

10kv Aluminum Core PE Insulated Cable Overhead

Mining Type41 Rneda Drum 50mm2 China Power Drailing Cable Type61

20kv 1 2 3 4 Core Overhead Line ABC Cable ABC Aerial Bundle Cable

11kv Medium Voltage Overhead Cable 3X1X120mm2

Popular Power Cable Products

PVC Insulated PVC Sheathed Electric Wire and Cables

XLPE Insulated PVC Sheathed Power Cable Yjv Yjlv

LAN Cable PVC/XLPE Insulated Electrical Wire BV Bvr BVV BVVB Rvs

Underground Cable Steel Wire/Type Armoured Copper Power Cable

TUV Psb Losh Sheathed XLPE Insulated Fir Resistance Steel Wire Armored Cable

Security Fire Proof Resistance Rubber Cable Flame Retardance Copper Electric Power Cable

Popular wuhancable Products

Overhead Aluminum Alloy Conductor Service Drop XLPE/PVC Aerial Bundled Cable

11kv XLPE Covered Conductor

Aerial Bundled Cable up to 1kv

BV/BVVB/BVV PVC Insualted Electrical Wire (Housing Electrical Wire)

IEC61089 All Aluminum Alloy Condcutor AAAC 250

Tacsr Thermo-Resistance Aluminum Alloy Conductor Steel Reinforced

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION