Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor

China 
                        Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor
                      manufacture and supplier

Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor image

Get Latest Price Request a quote

Quick Details

Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor

3×50+54.6

Jytop

ISO9001, CCC

Primarily Overhead Secondary Distribution

Round Wire

XLPE

PVC

Aluminum

Overhead

Stranded

Insulated

ASTM

25 ºC

75ºC

0.91

0.95

Aerial Buindled Cable Overhead Transmission Line

JYTOP

500m / Rolls

ASTM standards

Zhengzhou, China

8544492100

Product Details

Quadruplex Service Drop ABC Aerial bundled Cable 3×25+54.6 Aluminium conductor

Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum, Insulated with either polyethylene or XLP cross-linked polyethylene, Neutral messengers are concentrically stranded 6201, AAC or ACSR .
 
Applications:
Quadruplex Service Drop is used to supply 3 phase power, usually from a pole mounted transformer to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
 
Standards:
Quadruplex service drop cable meets or exceeds the following ASTM specifications:
ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded.
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-399 Concentric-Lay-Stranded Aluminum Alloy Conductors 6201-T81.
 
Service drop cable meets or exceeds all applicable requirement of ANSI/ ICEA-S-76-474:

 

Technical characteristics :

Cores Nominal cross-sectional area Phase Conductors
insulation
Dia. Of cable R. of conductors at 20ºC Break strength of conductor
Ω/km KN
3C+1C mm2 Thickness (mm) mm Phase cores Neutral cores Phase cores Neutral cores
3C+1C 3×25+54.6 1.4 23.57 1.2 0.630 16.6 16.6
3C+1C 3×35+54.6 1.6 26.08 0.868 0.630 16.6 16.6
3C+1C 3×50+54.6 1.6 28.15 0.641 0.630 16.6 16.6
3C+1C 3×70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3×70+54.6 1.8 32.15 0.443 0.630 16.6 16.6
3C+1C 3×70+70 1.8 32.75 0.443 0.500 20.5 20.5
3C+1C 3×95+70 1.8 35.78 0.32 0.500 20.5 20.5
3C+1C 3×120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3×120+70 1.8 37.93 0.253 0.500 20.5 20.5
3C+1C 3×120+95 1.8 39.26 0.253 0.343 27.5 27.5
3C+1C 3×150+95 1.9 41.81 0.206 0.343 27.5 27.5


More about ABC Cable types, Plz contact our team. we’ll give reply ASAP.

1. Duplex Service Drop cable : 

Code
Word
Phase Conductors Bare Natural Nominal Weight Ampacity Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
AAC
Pekingese 6-Solid 1.14 4.1 6.4 6-7 255 20.8 72.9 94 78 305 1000
Collie 6-7 1.14 4.6 6.9 6-7 255 23.8 72.9 97 78 305 1000
Cocker 6-7 1.52 4.6 7.7 6-7 255 32.7 72.9 106 78 305 1000
Dachshund 4-Solid 1.14 5.2 7.5 6-7 400 26.8 114.6 141 103 305 500
Spaniel 4-7 1.14 5.9 8.2 6-7 400 29.8 116.1 146 103 305 500
Cairn 4-7 1.52 5.9 8.9 6-7 400 40.2 116.1 156 103 305 500
Doberman 2-7 1.14 7.4 9.7 2-7 612  38.7 184.5 223 136 152 500
Airedale 1-19 1.52 8.4 11.5 1-7 56.5 233.6 290 158 152 500
Basset 1/0-7 1.52 9.3 12.4 1/0-7 903  64.0  294.7 359 182 152 457
Malemure 1/0-19 1.52 9.4 12.5 1/0-7 903  64.0  294.7 359 182 152 457
                         
AAAC
Chihuahua 6-Solid 1.14 4.1 6.4 6-7 499 20.8 72.9 94 78 305 1000
Vizsla 6-7 1.14 4.6 6.9 6-7 499 23.8 72.9 97 78 305 1000
Harrier 4-Solid 1.14 5.2 7.5 4-7 798 26.8 116.1 143 103 305 500
Whippet 4-7 1.14 5.9 8.2 4-7 798 29.8 116.1 146 103 305 500
Schnauzer 2-7 1.14 7.4 9.7 2-7 1,270  38.7 184.5 223 136 152 500
Afghan 1/0-7 1.52 9.3 12.4 1/0-7 2,023  64.0  296.1 360 182 152 457
heeler 1/0-19 1.52 9.4 12.5 1/0-7 2,023  64.0  296.1 360 182 152 457
                         
ACSR
Setter 6-Solid 1.14 4.1 6.4 6/6/01 540 20.8 72.9 94 78 305 1000
Shepherd 6-7 1.14 4.6 6.9 6/6/01 540 23.8 72.9 97 78 305 1000
Retriever 6-7 1.52 4.6 7.7 6/6/01 540 32.7 72.9 106 78 305 1000
Eskimo 4-Solid 1.14 5.2 7.5 4/6/01 844 26.8 114.6 141 103 305 500
Terrier 4-7 1.14 5.9 8.2 4/6/01 844 29.8 116.1 146 103 305 500
Yorkshire 4-7 1.52 5.9 8.9 4/6/01 844 40.2 116.1 156 103 305 500
Chow 2-7 1.14 7.4 9.7 2/6/01 1,293  38.7 184.5 223 136 152 500
Labrador 1-19 1.52 8.4 11.5 1/6/01 1,610  56.5 233.6 290 158 152 500
Bloodhound 1/0-7 1.52 9.3 12.4 1/0-6/1 1,987  64.0  294.7 359 182 152 457
Bull 1/0-19 1.52 9.4 12.5 1/0-6/1 1,987  64.0  294.7 359 182 152 457

2. Triplex Service Drop cable :

Code
Word
Phase Conductors Bare Natural Nominal Weight Ampacity Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Al Total
mm mm mm kg A m m
                         
AAC
Halotis 6-Solid 1.14 4.115 6.4 6-7 255 42  110 152 78 305 762
Pike 6-7 0.76 4.67 6.2 6-7 255 31  112 143 78 305 762
Patella 6-7 1.14 4.67 7.0  6-7 255 48  112 159 78 305 762
Albus 6-7 1.52 4.67 7.7 6-7 255 64  132 198 78 305 762
Fusus 4-Solid 1.14 5.182 7.5 4-7 400 52  177 229 103 152 518
Oyster 4-7 1.14 5.89 8.2 4-7 400 60  177 237 103 152 457
Argo 4-7 1.52 5.89 8.9 4-7 400  80  177 258 103 152 457
Clam 2-7 1.14 7.42 9.7 2-7 612  76  281 359 136 152 549
Thia 2-7 1.52 7.42 10.5 2-7 612  100  281 383 136 152 549
Mussel 2-7 1.14 7.42 9.7 2-7 612  76  281 359 136 152 549
Pyrula 1-7 1.52 8.33 11.4 1-7 744 113  356 467 158 152 457
Hyas 1-19 1.52 8.43 11.5 1-7 744 115  356 469 158 152 457
Murex 1/0-7 1.52 9.35 12.4 1/0-7 903 128  385 513 182 152 366
Purpura 1/0-19 1.52 9.47 12.5 1/0-7 903 130  385 515 182 152 366
Nasa 2/0-7 1.52 10.52 13.6 2/0-7 1,139  146  566 710 210 457
Trophon 2/0-19 1.52 10.64 13.7 2/0-7 1,139  147  566 713 210 457
Quahog 3/0-7 2.03 11.79 15.9 3/0-7 1,379  214  713 926 242 396
lone 3/0-19 2.03 11.94 16.0  3/0-7 1,379  217  713 929 242 396
Melita 3/0-19 1.52 11.94 15.0  3/0-19 1,501  168  713 881 242 396
Coquila 4/0-7 1.52 13.26 16.3 4/0-7 1,737  191  899 1,089  279 305
Tusk 4/0-7 2.03 13.26 17.3 4/0-7 1,737  243  899 1,141  279 305
Apus 4/0-19 2.03 13.41 17.5 4/0-7 1,737  246  899 1,144  279 305
Portunus 4/0-19 1.52 13.41 16.5 4/0-19 1,823  194  899 1,091  279 305
Chiton 266.8-19 2.03 14.88 18.9 266.8-19 2,254  277  1,133  1,409  310 305
Nannynose 336.4-19 2.03 16.92 21.0  336.4-19 2,790  321  1,427  1,749  330 305

 

Code
Word

Phase Conductors Bare Natural Nominal Weight Ampacity Standard
 Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
AAAC
Homarus 6-Solid 1.14 4.115 6.4 6-7 499 42  118 159 78 305 762
Minex 6-Solid 1.14 4.115 13.3 6-7 499 42  118 159 78 305 762
Cabera 6-7 1.14 4.65 6.9  6-7 499 48  118 165 78 305 671
Hippa 6-7 1.14 4.65 6.9 6-7 499 48  118 165 78 305 671
Artemia 4-Solid 1.14 5.182 7.5 6-7 499 52  162 214 103 305 518
Maira 4-7 1.14 5.89 8.2 6-7 499 60  188 247 103 305 518
Crab 4-7 1.14 5.89 8.2 6-7 499 60  162 222 103 305 518
Luidia 4-Solid 1.14 5.182 7.5 6-7 499 52  162 214 103 152 518
Prawn 4-Solid 1.14 5.182 7.5 4-7 798  52  188 240 103 152 518
Metalia 4-7 1.14 5.89 8.2 4-7 798  60  188 247 103 152 457
Barnacles 4-7 1.14 5.89 8.2 4-7 798  60  188 247 103 152 457
Solaster 2-7 1.14 7.42 9.7 4-7 798  76  258 333 136 152 549
Pagarus 2-7 1.52 7.42 10.5 4-7 798  100  258 357 136 152 549
Shrimp 2-7 1.14 7.42 9.7 2-7 1,270  76  298 374 136 152 549
Lobster 2-7 1.52 7.42 10.5 2-7 1,270  100  298 397 136 152 549
Encope 1-19 1.52 8.43 11.5 2-7 1,270  115  347 461 158 152 366
Sanderab 1/0-7 1.52 9.35 12.4 2-7 1,270  128  409 537 182 152 366
Echinus 1/0-19 1.52 9.47 12.5  2-7 1,270  130  409 539 182 152 366
Gammarus 1/0-7 1.52 9.35 12.4 1/0-7 2,023  128  473 601 182 152 366
Leda 1/0-19 1.52 9.47 12.5 1/0-7 2,023  130  473 603 182 152 366
Crayfish 2/0-7 1.52 10.5 13.6  2-7 1,270  146  487 631 210 457
Sipho 2/0-19 1.52 10.6 13.7 2-7 1,270  147  487 634 210 457
Dungenese 2/0-7 1.52 10.5 13.6  2/0-7 2,445  146  595 740 210 457
Cyclops 2/0-7 1.52 10.6 13.7 2/0-7 2,445  147  595 743 210 457
Slug 3/0-7 1.52 11.8 14.8 1/0-7 2,023  165  650 816 242 366
Fulgur 3/0-19 1.52 11.9 15.0  1/0-7 2,023  168  650 819 242 366
Balanus 3/0-19 2.03 11.9 16.0  1/0-7 2,023  216  650 868 242 366
Stonecrab 3/0-7 1.52 11.8 14.8  3/0-7 3,080  165  752 917 242 366
Flustra 3/0-7 1.52 11.9 15.0  3/0-7 3,080  168  752 920 242 366
Crisia 3/0-19 2.03 11.9 16.0  3/0-7 3,080  216  752 969 242 305
Squid 4/0-7 1.52 13.3 16.3 2/0-7 2,431  191  820 1,011  279 305
Arca 4/0-19 1.52 13.4 16.5 2/0-7 2,431  192  820 1,012  279 305
Bugula 4/0-19 2.03 13.4 17.5 2/0-7 2,431  246  820 1,066  279 305
Kingerab 4/0-7 1.52 13.3 16.3 4/0-7 3,883  191  948 1,137  279 305
Lepas 4/0-19 1.52 13.4 16.5 4/0-7 3,883  192  948 1,140  279 305
Cassi 4/0-19 2.03 13.4 17.5  4/0-7 3,883  246  948 1,194  279 305

 

Code
Word

Phase Conductors Bare Natural Nominal Weight Ampacity Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Al Total
mm mm mm kg A m m
ACSR
Paludina 6-Solid 1.14 4.115 6.401  6-6/1 540 42  112 170 79 305 762
Voluta 6-7 1.14 4.67 6.960  6-6/1 540 48  112 176 79 305 671
Bolma 6-7 1.52 4.67 7.722  6-6/1 540 64  112 194 79 305 671
Scallop 4-Solid 1.14 5.182 7.468  6-6/1 540 52  155 225 138 152 518
Strombus 4-7 1.14 5.89 8.179  6-6/1 540 60  155 232 138 152 457
Carnea 4-7 1.52 5.89 8.941  6-6/1 540 80  155 253 138 152 457
Whelk 4-Solid 1.14 5.182 7.468  4-6/1 844 52  177 258 138 152 518
Periwinkle 4-7 1.14 5.89 8.179  4-6/1 844 60  177 263 138 152 457
Calma 4-7 1.52 5.89 8.941  4-6/1 844 80  177 284 138 152 457
Cockle 2-7 1.14 5.89 8.179  4-6/1 844 60  247 335 183 152 549
Gebia 2-7 1.52 5.89 8.941  4-6/1 844  80  247 354 183 152 549
Conch 2-7 1.14 5.89 8.179  2-6/1 1,293  60  281 384 183 152 549
Uca 2-7 1.52 5.89 8.941  2-6/1 1,293  80  281 405 183 152 549
Vermeths 1-7 1.52 8.33 11.379  1-6/1 1,610  113  354 522 210 152 457
Atya 1-19 1.52 8.33 11.379  1-6/1 1,610  113  430 524 210 152 457
Janthina 1/0-7 1.52 8.33 11.379  2-6/1 1,293  113  393 549 242 152 366
Ranella 1/0-19 1.52 9.47 12.522  2-6/1 1,293  130  393 566 242 152 366
Neritina 1/0-7 1.52 9.35 12.395  1/0-6/1 1,987  128  448 644 242 152 366
Cenia 1/0-19 1.52 9.47 12.522  1/0-6/1 1,987  130  448 646 242 152 366
Cavolinia 2/0-7 1.52 10.5 13.564  1-6/1 1,610  146  496 697 279 579
Clio 2/0-19 1.52 10.6 13.691  1-6/1 1,610  147  496 698 279 457
Runcina 2/0-7 1.52 10.5 13.564  2/0-6/1 2,404  146  564 796 279 457
Triton 2/0-19 1.52 10.6 13.691  2/0-6/1 2,404  147  564 799 279 457
Sanddollar 3/0-7 1.52 11.8 14.834  1/0-6/1 1,987  165  625 860 322 396
Aega 3/0-19 1.52 11.9 14.986  1/0-6/1 1,987  168  625 862 322 396
Pisa 3/0-19 2.03 11.9 16.002  1/0-6/1 1,987  216  625 911 322 396
Cherrystone 3/0-7 1.52 11.8 14.834  3/0-6/1 3,003  165  711 987 322 396
Mursia 3/0-19 1.52 11.9 14.986  3/0-6/1 3,003  168  711 990 322 396
Mysis 3/0-19 2.03 11.9 16.002  3/0-6/1 3,003  216  711 990 322 396
Cuttlefish 4/0-7 1.52 13.3 16.307  2/0-6/1 2,404  191  787 1,066  372 305
Cerapus 4/0-19 1.52 13.4 16.459  2/0-6/1 2,404  192  787 1,069  372 305
Nepatus 4/0-19 2.03 13.4 17.475  2/0-6/1 2,404  246  787 1,121  372 305
Razor 4/0-7 1.52 13.3 16.307  4/0-6/1 3,788  191  897 1,226  372 305
Zuzara 4/0-19 1.52 13.4 16.459  4/0-6/1 3,788  192  897 1,229  372 305
Alima 4/0-19 2.03 13.4 17.475  4/0-6/1 3,788  246  897 1,281  372 305
Callista 266.8-19 2.03 15.1 19.126  3/0-6/1 3,003  280  994 1,384  410 305
Dosinia 266.8-19 2.03 15.1 19.126  266.8-18/1 3,121  280  1,133  1,472  410 305
Cowry 336.4-19 2.03 16.9 20.980  4/0-6/1 3,788  320  1,253  1,713  506 305
Limpet 336.4-19 2.03 16.9 20.980  336.4-18/1 3,937  320  1,429  1,823  506 305

3.Quadruplex Service Drop Cable :

Code
Word
Phase Conductors Bare Natural Nominal Weight Ampacity* Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
AAC
Quarter 6-Solid 1.143 4.115 6.401 6-7 255.371 63 149 211 78 152.4 762.0
Clydesdale 4-Soild 1.143 5.182 7.468 4-7 399.613 79 237 315 103 152.4 518.2
Pinto 4-7 1.143 5.893 8.179 4-7 399.613 89 237 326 136 152.4 518.2
Musang 2-7 1.143 7.417 9.703 2-7 612.347 115 377 491 158   548.6
Shire 1-19 1.524 8.433 11.481 1-19 743.888 171 475 646 158   457.2
Libyan 1/0-7 1.524 9.347 12.395 1/0-7 902.644 192 598 790 182   365.8
Criollo 1/0-19 1.524 9.474 12.522 1/0-19 902.644 193 598 793 182   365.8
Orloff 2/0-7 1.524 10.516 13.564 2/0-7 1138.511 217 754 973 210   457.2
Percheron 2/0-19 1.524 10.643 13.691 2/0-19 1138.511 220 754 976 210   457.2
Mongolian 3/0-7 1.524 11.786 14.834 3/0-7 1378.914 249 951 1199 242   396.2
Hanoverian 3/0-19 1.524 11.938 14.986 3/0-19 1378.914 251 951 1204 242   396.2
Singlefoot 4/0-7 1.524 13.259 16.307 4/0-7 1737.250 286 1199 1485 279   335.3
Oldenburg 4/0-19 1.524 13.411 16.459 4/0-19 1737.250 289 1199 1490 279   335.3

 

Code
Word

Phase Conductors Bare Natural Nominal Weight Ampacity* Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
AAAC
Bay 6-Solid 1.143 4.115 6.401 6-7 503.485 63 155 217 78 152.4 762.0
French-conch 6-7 1.143 4.674 6.960 6-7 503.485 71 155 226 78 152.4 762.0
German-conch 4-solid 1.143 5.182 7.468 4-7 798.318 79 247 324 103 152.4 518.2
Arabian 4-7 1.143 5.893 8.179 4-7 784.711 89 247 336 103   518.2
Belgian 2-7 1.143 7.417 9.703 2-7 1270.052 115 391 506 136   548.6
Saddle 1-19 1.524 8.433 11.481 2-7 1270.052 171 466 637 158   457.2
Plow 1/0-7 1.524 9.347 12.395 1/0-7 2023.011 192 624 814 182   365.8
Sherland 1/0-19 1.524 9.474 12.522 1/0-7 2023.011 193 624 817 182   365.8
Dapple-grey 2/0-7 1.524 10.516 13.564 2/0-7 2444.850 217 786 1005 210   457.2
Thoroughbred 2/0-19 1.524 10.643 13.691 2/0-7 2444.850 220 786 1007 210   457.2
Dobbin 3/0-7 1.524 11.786 14.834 3/0-7 3079.876 249 991 1238 242   396.2
Troter 3/0-19 1.524 11.938 14.986 3/0-7 3079.876 251 991 1243 242   396.2
Pony 4/0-7 1.524 13.259 16.307 4/0-7 3882.730 286 1250 1534 279   335.3
Walking 4/0-19 1.524 13.411 16.459 4/0-7 3882.730 289 1250 1539 279   335.3

 

Code
Word

Phase Conductors Bare Natural Nominal Weight Ampacity* Standard 
Package
Size &
Number
of wires
Insulation
Thickness
Nominal Diameter Size &
Number
of Wires
Rated
Strength
kg / km Coils Reels
Bare OD XLPE Aluminum Total
mm mm mm kg A m m
                         
ACSR
Morochuca 6-Solid 1.143 4.115 6.401 6-6/1 539.772 63 149 229 78 152.4 762.0
Chola 6-7 1.143 4.674 6.960 6-6/1 539.772 71 149 237 78 152.4 762.0
Morgan 4-solid 1.143 5.182 7.468 4-6/1 843.667 79 238 344 103 152.4 518.2
Hackney 4-7 1.143 5.893 8.179 4-6/1 843.667 89 238 356 103   518.2
Palomino 2-7 1.143 7.417 9.703 2-6/1 1292.732 115 377 557 136   548.6
Albina 1-19 1.524 8.433 11.481 2-6/1 1610.245 171 473 699 158   457.2
Standardbred 1/0-7 1.524 9.347 12.395 1/0-6/1 1986.724 192 598 859 182   365.8
Costena 1/0-19 1.524 9.474 12.522 1/0-6/1 1986.724 193 598 862 182   365.8
Chicoeagues 2/0-7 1.524 10.516 13.564 2/0-6/1 2404.027 217 753 1060 210   457.2
Grullo 2/0-19 1.524 10.643 13.691 2/0-6/1 2402.027 220 753 1063 210   457.2
Mare 3/0-7 1.524 11.786 14.834 3/0-6/1 3002.766 249 951 1308 242   396.2
Suffolk 3/0-19 1.524 11.938 14.986 3/0-6/1 3002.766 251 951 1313 242   396.2
Stallion 4/0-7 1.524 13.259 16.307 4/0-6/1 3787.477 286 1198 1622 279   335.3
Appaloosa 4/0-19 1.524 13.411 16.459 4/0-6/1 3787.477 289 1198 1627 279   335.3

* Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201. Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft/sec. wind in sun.
** To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.
The data is approximate and subject to normal manufacturing tolerances.

We are China Quadruplex Service Drop ABC Aerial Bundled Cable 3X25+54.6 Aluminium Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

15kv Spacer Cable-Tree Wire 10kv ABC Cable ANSI/Icea S-76-474

0.6/1 Kv ABC Cable Triplex Service Drop Hippa /Shrimp/Dungenese

ASTM Standard Duplex, Triplex AAC ACSR Neutral ABC Cable

ABC Cable Aluminum PE/XLPE for Overhead

LV NFC Standard 3X70+54.6+16mm2 Aluminum XLPE Aerial Bundled Cable

0.6/1 Kv Low Voltage ABC Cable 2X4 AWG ASTM

Popular jytopcable Products

Flexible Wire H07z1-K with Lsoh or Lsfh or LSZH Insulation

Rvv Type 300/300V Circular Light Flexible Cable with PVC Sheathed

All Aluminum Conductor AAC Spider AAC Conductor to BS215-1

Bare Conductor AAAC All Aluminum Alloy Conductor Almelec Conductor

H07V-U PVC Insulated Solid Wire

450/750V PVC Coated Wire, Electric Wire H07V-K Cable

Popular Overhaed Cable Products

  • No related articles
  • Popular Quadruplex Cable Products

    Quadruplex Service Drop Power XLPE Electric Aluminum ABC Cable

    ABC Aerial Bunded Cable Aluminium Conductor XLPE Insulated Bundled Cable

    Duplex/Triplex/Quadruplex Cable ASTM Standard XLPE Insulated Service Drop Cables

    Overhead Quadruplex Cable Aerial Bundled Cable

    Duplex Triplex Quadruplex ABC Cable Aerial Bundled Cable

    PE Insulted Quadruplex Overhead Cable ABC Cable Bare Neutral Conductor