RW12f 15kv 24kv 100A 200A Outdoor High Voltage Drop out Fuse Cut out

China 
                RW12f 15kv 24kv 100A 200A Outdoor High Voltage Drop out Fuse Cut out
              manufacture and supplier

RW12f 15kv 24kv 100A 200A Outdoor High Voltage Drop out Fuse Cut out image

Get Latest Price Request a quote

Basic Info.

Model NO.
RW12F

Standard
UL

Rated Voltage
15/24/36kv

Rated Currrent
100-200A

Fuse Current
100-200A

Rated Frequency
50Hz

Use
Transmission Line Branch and Transformer Protecti

Place of Use
Outdoor

Material
Ceramic

Frequency Voltage Wet
30kv

Frequency Voltage to Dry
42kv

The Rated Voltage Lightning Shock
125kv

Leakae Distance
250/320/530/900mm

Mechanical Life
500 Times

Breaking Current
6300-12500A

Weight
6-8kg

Impulse Voltage Bil
110/125/150/170 Bil

Transport Package
Carton/ Shipping

Specification
40*36*11.5cm/50*38*16cm

Trademark
CNKC

Origin
China

Production Capacity
5000PCS/Monthly

Product Description

Product Description
RW12F series drop-out fuses are outdoor high-voltage protection appliances in power transmission and distribution systems. They are installed on the high-voltage side of distribution transformers or on branch lines of distribution lines, and are used for short-circuit and overload protection of transformers and lines, as well as split and combined load currents. The high-voltage ceramic drop-out fuse is composed of a ceramic insulating bracket and a fuse tube. The static contact is installed at both ends of the insulating bracket, and the moving contact is installed at both ends of the fuse tube. The fuse tube is composed of the inner arc suppression tube and the fuse tube. The outer layer is composed of phenolic paper tube or epoxy glass cloth tube. The load drop type fuse enhances the elastic auxiliary contact and arc extinguishing cover to divide and combine the load current.

Model Description

Product technical parameters and installlation size

Bracket installation diagram: 

Product installation effect:

Product features and scope of use

Melt tube structure:
Fuse take made of flberglsaa, damp-proof & corrosion-proof.
Fuse base:
Product base embedded mechanical structure and insulator. Install metal rod mechanism using special binder materials and insulator together , can with stand short-circuit current open the electric power.
Moistureproof fuse has not blister, deformation, open ,large capacity, UV,long life, superior electric properties, dielectric strength and excellent mechanical stiffness and consecrated ability.
The whole organization to neutral, convenient installation, safe and reliable.
1. The ambient temperature is not higher than +40 C, not lower than-40 C
2. The altitude does not exceed 3000m
3.The maximum wind speed does not exceed 35m/s
4. The earthquake intensity does not exceed 8 degrees

Fuse Installation and Operation

1. Installation of drop fuse:
(1) The melt should be tightened during installation (so that the melt is subjected to a tensile force of about 24.5N), otherwise it is easy to cause the contact to overheat.
(2) The fuse installed on the cross arm (frame) should be firm and reliable, and there should be no shaking or shaking.
(3) The melting tube should have a downward inclination angle of 25°±2°, so that the melting tube can quickly fall by its own weight when the melt is blown.
(4) The fuse should be installed on the cross arm (frame) with a vertical distance of not less than 4m from the ground. If it is installed above the distribution transformer, it should maintain a horizontal distance of more than 0.5m from the outer contour boundary of the distribution transformer. A fall of a melting tube caused other accidents.
(5) The length of the fuse tube should be adjusted moderately. It is required that the duckbill tongue can hold more than two-thirds of the length of the contact after closing, so as to avoid the misoperation of self-falling during operation, and the fuse tube should not hit the duckbill. , in order to prevent the melting tube from falling in time after the melt is blown.
(6) The melt used must be a standard product of a regular manufacturer, and has a certain mechanical strength. Generally, the melt is required to withstand a tensile force of more than 147N.
(7) The 10kV drop-out fuse is installed outdoors, and the distance between phases is required to be greater than 70cm.
Second, the operation of the drop fuse:
Under normal circumstances, it is not allowed to operate the drop fuse with load, only it is allowed to operate the no-load equipment (line). However, branch lines of 10kV distribution lines in rural power grids and distribution transformers with rated capacity less than 200kVA are allowed to operate with load according to the following requirements:
(1) The operation shall be carried out by two persons (one to monitor and one to operate), but must wear qualified insulating gloves, insulating boots, and goggles, and operate with qualified insulating rods with matching voltage levels. Operation is prohibited in heavy rain.
(2) During the operation of the gate, it is generally stipulated that the middle phase is pulled first, then the leeward side phase is pulled, and then the windward side phase is pulled. This is because the distribution transformer is changed from three-phase operation to two-phase operation, and the arc spark generated when the intermediate phase is broken is small, which will not cause a short circuit between phases. The second is to break the leeward side phase, because the middle phase has been pulled apart, and the distance between the leeward side phase and the windward side phase has doubled. Even if there is an overvoltage, the possibility of short circuit between phases is very small. When the windward side phase is pulled back, there is only a capacitive current to the ground, and the spark generated is very slight.
(3) When closing, the operation sequence is reversed when closing, first close the windward side phase, then close the leeward side phase, and then close the middle phase.
(4) Operating the melting tube is a frequent item. If you don’t pay attention, it will cause the contact to burn and cause poor contact, overheat the contact, and anneal the spring, which will make the contact worse and form a vicious circle. Therefore, when pulling and closing the fusion tube, use moderate force. After closing, carefully check that the duckbill tongue can be tightly buckled for more than two-thirds of the length of the tongue. You can use the brake lever to hook the upper duckbill and press down a few times. Try pulling again to check if it fits properly. When the switch is closed, it is not in place or not firmly closed, and the static contact pressure on the fuse is insufficient, which can easily cause the contact to burn or the fuse tube to fall by itself.

Product details

Products real shot

A corner of the production workshop

Product packaging

Product application case

 

 
/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

We are China RW12f 15kv 24kv 100A 200A Outdoor High Voltage Drop out Fuse Cut out manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular cnkcele Products

Kc 30-4000kVA Single-Phase Gasket Transformer

Ybf-35/0.4kv 630-2500kVA Special Box-Type Substation for Photovoltaic Wind Power Station

Zr-Bvr 1.5/2.5/4/6mm² 450/750V Low-Voltage Flame-Retardant Multi-Core Soft Copper Wire

Jdz9 3/6/10kv 30-500va Dry-Type Fully Enclosed Single-Phase Indoor Hv Voltage Transformer

Metering Current Transformer Voltage and Current Combined Transformer (measuring box)

Tl 185-630mm² 22-34.5mm The Pressure Plate Type T-Connectors for Single Conductor of Bolt Type

Popular Drop out Fuse Cut out Products

Xrnt 10/24 Kv Type Hhd Fuse for Air and Gas Switch

Hrw 12kv 35kv 100A 200A Outdoor High Voltage Drop-out Fuse Cut out

11kv-33kv High Voltage Drop out Fuse Cutout K, T Type Fuse Link 5A 10A 15A 200A

Popular Outdoor Drop out Fuse Products

Hrw 12/24kv High Voltage Composite Drop Fuse Drop Switch with Arc Chute

Hy5wbg Outdoor 10kv Line Pillar Zinc Oxide Arrester with Bracket No Gap Discharge

Bdgh Series 7.2-40.5kv 50ka Low Price High Voltage Current Limiting Fuses Link for Transformer Protection British BS Standards

Xrnp 6kv 12kv 40.5kv 50ka High Voltage Current Limiting Fuses Link for Protection of Voltage Transformers

Yh5ws 10/35kv Compound Zinc Oxide Surge Arrester High Voltage Distribution Type

Rn Series 3-40.5kv 50ka 2023 Made in China New Type Indoor Medium and High Voltage Fuses Link

Popular RW12f 15kv 24kv 100A 200A Outdoor High Voltage Drop out Fuse Cut out Products

  • No related articles
  • Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION