Sleeve, Pre-Insul. Service No. Es 2W2w
Sleeve, Pre-Insul. Service No. Es 2W2w image
Get Latest Price Request a quote
Quick Details
Product Details
Side A | Side B | Die Index |
Tools, Die Set Catalog Number, & (Crimps per End) | ||||
ACSR | Aluminum & Copper | Color Code |
ACSR | Aluminum & Copper | Color Code |
||
4 |
3, 4 Str. 2 Sol. |
Orange |
4 |
3, 4 Str. 2 Sol. |
Orange |
BG or 5/8 |
General
Application For Insulated Combinations of Copper, Aluminum, ACSR Compressed
Conductors and In Overhead Distribution
EU RoHS Indicator Insulation Insulation Type Material
Plated
Plating Type
Orange
Orange
BG or 5/8
Yes
Yes
Nylon
Aluminum
Yes
Tin – Hot Dipped
Prefilled Oxide Inhibitor Yes
Type Insulated Service Entrance Connectors
Dimensions
Dimension – L Length Overall mm 70 mm
Dimension – Length Overall inch 2.75 in
Dimension – Outside Diameter inch .75 in
The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
CSA CANADIAN STANDARDS ASSOCIATION
G164-4 – Hot dip galvanizing of Irregular Shaped Articles
CAN/CSA – Quality Assurance Program Categories 2299.3
ANSI – AMERICAN NATIONAL STANDARDS INSTITUTE
C29.1 – American Standard Test Method For Electrical Power Insulators
C29.7 – American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
987-1985 – IEEE Guide For Application of Composite Insulators
D750 – Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
D1499 – Recommended Practice For Exposure of Plastics.
D2240 – Rubber Properties, Durometer Hardness
D2565 – Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core
The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
i. are compressed onto the Fibreglass rod member
ii. are not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii. are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
The insulator are provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load.
Performance Characteristics
The Polymeric Insulators are meet the under listed performance characteristics.
ITEM |
11kV |
33KV |
Dry Flashover Withstand |
90kV |
180kV |
Wet flashover withstand |
70kV |
165kV |
Positive Impulse Critical flashover |
145kV |
300kV |
Maximum Radio Interference Voltage |
Below 1micro volt |
Below 1 micro volt |
Design Tension Strength |
100kN |
100kN |
Residual Strength after Power Arc |
80kN |
80kN |
Mechanical Proof Test Load |
45kN |
45kN |
Maximum Sustained Load |
34kN |
34kN |
Design Torque Rating |
83 Nm |
83 Nm |
The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.
Recommended for You
Not exactly what you want?
Post Sourcing Request
Hot Searches
Voltage Insulator
High Voltage Insulator
Rubber Insulator
Ceramic Insulator
Silicon Insulator
We are China Sleeve, Pre-Insul. Service No. Es 2W2w manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Composite Insulator Products
St-10 Electrical Porcelain Pin Type Insulators
Outdoor Grounding Wire (double tongue type)
St-20j 22kv Pin Porcelain Insualtor/22kv Porcelain Pin Type Insulator/St-20j Insulator
24kv Cantilever Composite Insulator Double Insulation Catenary
Silicon Rubber High Voltage Insulator
Xgj Suspension Clamp (1, 2, 3)
Popular jgtrade1 Products
U3 Knitted Nitrile Gloves Polyester Black 7-11
Cable 19′33kv 3core 70mm2 Insulated (Underground Cable)
Connector Wedge to Pressure 1/0 AWG with Stirrup
Metal Oxide Surge Arrester (36KV)
Terminal Connectors Type Sy, Compression Type, Group a
Stay Rod Assembly M20 Conventional
Popular Polymer Insulator Products
High Voltage120kn Suspension Glass U120BS 33kv Disc Insulator
33kv Silicon Pin Insulator 10kn SPA660XP Polymer Composite Insulator Polymeric Post 11kv 15kv 22kv
Tension Set for 11kv Overhead Lines
Terminal, Aluminium Compression-Cableto Flat-4 Hole: Ccls 642c
Polymer Composite Suspension Disc Dead End Long Rod Insulator
Popular Silicone Rubber Insulator Products
126-363kv Anti-Pollution Sol1d-Core Post Porcelain Insulator
Bolt & Nut, Machine 5/8" X 12"
Tags: Composite Insulator, jgtrade1, Polymer Insulator, Silicone Rubber Insulator