Smico 1 Kv Insulating Piercing Connector for ABC Cable
Smico 1 Kv Insulating Piercing Connector for ABC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Insulation piercing connector is mainly suitable for the connection of the overhead insulation conductor, branch connection and grounding protection, It is used for the voltage which is 20KV, 10KV and 1KV and below. Applicable for Al-Cu conductor, different diameter wire connection, and equal diameter wire butt, and is suitable for the transition of copper aluminum insulation conductor link.
| Modle | Conductor Range(mm2) | Bolts | |
| Main | Tap | ||
| DP10 | 50-70 | 50-70 | M8 |
General of insulation piercing connector(lPC)
1.1 Piercing connector, simple installation, need not strip the cable coat.
1.2 Moment nut, piercing pressure is constant, keep good electrìc connection and make no damage to lead
1.3 Self-seam frame,wetproof, waterproof,and anti-corrosion, extend the using life of insulated lead and connector
1.4 Adopted special connectìng tablet, apply to joint of Cu(Al) and Cu(Al) or Cu and Al
1.5 Small electric connecting resistance, connecting resistance less than 1.1 tìmes of the resistance of branch conductor wìth the same length
1.6 Special insulated case body, resistance to illuminatìon and environmental aging, the insulation strength can up to 12KV
1. 7 Arc surface design,apply to connection with the same(different) diameter, wide connection scope(0.75mm2-400mm2)
(Performance testing)
2.1 Mechanical performance:the grip force of the wire clamp is 1/10 bigger than the break force of the lead. It comply with GB2314-1997
2.2 Temperature rise performance: under the conditìon of big current, the temperature rise of connector is less than that of connection lead.
2.3 Heat circle performance:confirms to GB/T2317.3-2000,the beat circle trial standard for electric fitting.
2.4 Waterproof insulatìon performance:confirms to the relevant requirements in Part 2 of GB/TI3140.4-1998,
2.5 Resistance to corrosion performance: under the conditìon of SO, and salt fog, it can do three tìmes of fourteen days circle testìng.
2.6 Environmental aging performance:under the circumstance of ultraviolet, radiation, dry and moist, expose if with change of temperature and beat impulse for six weeks.
2.7 Fire-proof performance: insulation material of the connector withstands glowing filament test. Confirm to the requirements in Chapter4-1 0 of GBrr5169.4
We are China Smico 1 Kv Insulating Piercing Connector for ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1 Kv Products
Popular cnsmico Products
EMC Auto Maker Industrial Heavy Duty Connector
Male Female 6 Pins Connector Plug and Socket HSB-006 35A Heavy Duty Connector
Pneumatic Contact with Shut off Used for Module Docking Heavy Duty Connector
H48b-Sg-CV-1L Han B Series Connector
35 AMP 6 Pin Heavy Duty Wire Connector Harting Han Sb Rectangular Connector 09310062601
Four Core Adjustable Plastic Four Core Dead End Clamps
Popular Insulated Piercing Clamp Products
Ce TUV Electric Insulated Piercing Cable Clamp
Waterproof Insulation Piercing Connector for 1kv Insulation Cable Connecting
Low Voltage ABC Cable Insulation Piercing Connector for Cable Joint
Low Voltage Insulation Piercing Connector for ABC Cable
ABC Cable Insulation Piercing Connector (IPC) (50-185, 50-150, JMA185)
RoHS Waterproof Insulation Piercing Tap Clamp
Popular Insulating Piercing Connector Products
Insulating Piercing Connector Ipc3.4
Insulating Piercing Connector Jjc10-240/95
Tags: 1 Kv, cnsmico, Insulated Piercing Clamp, Insulating Piercing Connector