High Voltage Substation Lightning Arresters Manufacturers of 66kV Surge Arrester
0.25kV~750kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Surge Arresters’ Technical Parameters:
Type | Y10W5-66/176 |
Rated voltage———kV | 66 |
MCOV —————-kV | 52.8 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 221 |
8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 178 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 137 |
1mA D.C reference voltage (kV) | 96 |
Line discharge level | 1 |
2mS long duration impulse current A | 400 |
4/10μS High current impulse kA | 100 |
Lightning impulse withstand kV | 325 |
Power frequency voltage withstand(dry/wet)kV | 140 |
0.1S TOV————–kV | 79.2 |
1S TOV—————-kV | 75.9 |
10S TOV—————kV | 72.6 |
1200S TOV————-kV | 66 |
Creepage distance —-mm | 2500 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition: | Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | ||||||||
48HZ<Rated frequency<62HZ | ||||||||
Power frequency voltage should not be more than continuous running voltage | ||||||||
Max wind speed should be less than 35m/s | ||||||||
Earthquake intensity should be less than 7 degree | ||||||||
If used in contamination area, should be noted in advance. |
Lightning Arresters Production:
We are China SPD Gray Brown Surge Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Arrester Products
33kv Drop out Type Lighting Arrester
Low Voltage 12V 12kv Moa Surge Lightning Arrester
Yh5w-10, Seamless Composite Lighting Arrester
Porcelain Surge Arrester/Lightning Arrester
Xirui Porcelain Surge Arrester/Lightning Arrester
Wholesale High Voltage Porcelain Metal Oxide Lightning Arrestors Surge Arresters
Popular hzyddq Products
High Voltage Horizontal Centre - Break Disconnector
Metal Oxide Varistor MOV Block Electrical Railway Surge Protection
30kv/33kv Moa Porcelain Composite Surge Arrester ZnO Arrestor for Station
Motor-Driven Operating Mechanism Boxes for Earthing Switch
Electric Motor Operator for Isolator
Arresteor Low Voltage Rated Voltage 12kv/Hangzhou Professional Manufactory
Popular Surge Arrester Products
245kv-362kv AC System Gapless Metal Oxide Arrester with Polymer Housed
Fuse Cutout, Drop out Fuses 60kv 100A
Fuselink, Cartridge 415V - 30 AMPS -Me30A
Yh10W-9, Sharp Head 10kv 9ka Surge Arrester
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
High Quality 33kv Outdoor Metal Oxide Lightning Arrester
Popular Surge Protector Products
15kv Metal Oxide Surge Protector Arrester for Outdoor
High Voltage Surge Protective Silicon Polymer Lightening Arrester 50 Ka
18kv Electrical Accessories Metal Oxide 3 Phase Ese Lighting Arrester
30 Kv Metal-Oxide Polymer Surge Arrester with Bracket
Polymer Housed Transformer Protector Arrestor Lightning
Substation Surge Arrester 132kv 66kv 275kv
Tags: Arrester, hzyddq, Surge Arrester, Surge Protector