Station Class Ceramic Housed Gapless ZnO Arresters
Station Class Ceramic Housed Gapless ZnO Arresters image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
Type | Y10W5-120/313 |
Rated voltage———kV | 120 |
MCOV —————-kV | 98 |
Nominal Current——-kA | 10 |
Residual voltage of steep impulse—-at 5kA(kV) | 360 |
8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 304 |
Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 239 |
1mA D.C reference voltage (kV) | 174 |
Line discharge level | 3 |
2mS long duration impulse current A | 850 |
4/10µS High current impulse kA | 100 |
Lightning impulse withstand kV | 550 |
Power frequency voltage withstand(dry/wet)kV | 230 |
0.1S TOV————–kV | 144 |
1S TOV—————-kV | 138 |
10S TOV—————kV | 132 |
1200S TOV————-kV | 120 |
Creepage distance —-mm | 3906 |
Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
Environment temperature: -40–+40 degree | |||||||
altitude:<1000m | |||||||
48HZ<Rated frequency<62HZ | |||||||
Power frequency voltage should not be more than continuous running voltage | |||||||
Max wind speed should be less than 35m/s | |||||||
Earthquake intensity should be less than 7 degree | |||||||
If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Station Class Ceramic Housed Gapless ZnO Arresters manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Easy Assembled 245kv 1250/4000A High Voltage Disconnect Isolator Switch
Electrical Parts Zinc Oxide Zov Varistor Resistor MOV
Hangzhou Electrical Equipment Supplies 220V Surge Protection Device
Electrical Equipment Supplies Drop-out Types Ceramic Fuses of High Voltage
Surge Protection Device Lightning Arrester
132kv Transmission Line Type 24kv 10ka Lightning Arrester Without Gap
Popular Lightning Arrester Products
12kv High Quality Electrical Lightning Arrester for Transmission Line
Rated Voltage 100kv 110kv 120kv Transmission Line Type ZnO Lightning Diverter
Kema Tested 220kv Equipment Substation Composite Moa Lightening Arrester
Yh5w-18 Polymeric Silicone Rubber Lightning Arrester
35kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
Popular Surge Arrester Products
10ka 36kv Outdoor High Voltage Lightning Protection Surge Arrester Moa
24kv Composite Surge Arrester Lightning Arrester Metal Oxide Gapless Polymer Synthetic Polymeric
30kv to 132kv Line Polymer Metal Oxide Composite Surge Arrester
Xirui Ceramic Surge Arrester 10kv Porcelain Lighting Arrester
Medium Voltage 18kv 10ka Composite Zinc Oxide Surge Arrester
12kv 100A 10ka Polymer Housed Gapless Surge Arrester
Popular Surge Arresters Products
30kv/10ka Metal-Oxide Polymeric Surge Arrester
High Voltage Transmission Line Polymer Silicone Rubber Zinc-Oxide Lightning Arrestor
Porcelain Housing Zinc Oxide Lightning Arrester with Kema
Rated Current 5ka Polymeric Housed Station Class Surge Diverters with Counter
3-36kv Polymeric Lightning Arresters/Surge Arrester with Gap &Gap-Less Polymer Housed
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters