Station Class Ceramic Housed Gapless ZnO Arresters
Station Class Ceramic Housed Gapless ZnO Arresters image
Get Latest Price Request a quote
Quick Details
Product Details
Main features:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type | Y10W5-120/313 |
| Rated voltage———kV | 120 |
| MCOV —————-kV | 98 |
| Nominal Current——-kA | 10 |
| Residual voltage of steep impulse—-at 5kA(kV) | 360 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 304 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 239 |
| 1mA D.C reference voltage (kV) | 174 |
| Line discharge level | 3 |
| 2mS long duration impulse current A | 850 |
| 4/10µS High current impulse kA | 100 |
| Lightning impulse withstand kV | 550 |
| Power frequency voltage withstand(dry/wet)kV | 230 |
| 0.1S TOV————–kV | 144 |
| 1S TOV—————-kV | 138 |
| 10S TOV—————kV | 132 |
| 1200S TOV————-kV | 120 |
| Creepage distance —-mm | 3906 |
| Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Station Class Ceramic Housed Gapless ZnO Arresters manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
OEM Polymer Silicone Material 30kv 10ka Class 2 Type High Voltage Arrester
Wholesale Price High Quality Transmission Line 18kv Metal-Oxide Surge Arrester
110kv Metal Oxide Lightning Arrester
Transmission Line Type Coaxial Lightning Current Metal-Oxide Surge Arrestor
Double-Column High Voltage Centre Break Disconnector
3 Phase Three Column Disconnector Gw9
Popular Lightning Arrester Products
500kv Outdoor Substation Ceramic Housing Zinc-Oxide Surge Arrester Without Gaps
Y10W-11kv Porcelain Housed Suege Arrester for AC Power Distribution System
Hy10W-12, 12kv 10ka Surge Arrester
Class 3 SL Type Surge Arrester
Surge Protection Surge Arrester Suppressor
Yh10W-54, Sharp Head 54kv 10ka Surge Arrester
Popular Surge Arrester Products
Load Break Switch Fuse Disconnector 35kv 200A
9-12kv Silicon Polymer Surge Arrester, Lightning Arrester
Yh10W Polymeric Housed Metal-Oxide Lightning Surge Arrester Without Gaps
Ruitian Zinc Oxide Arrester 11kv Porcelain Surge Arrester
Line Material High Quality Disconnector, Hoop, Copper Wires for Lightning Arrestor
Popular Surge Arresters Products
24kv 10ka Polymer Housed Surge Arrester
Metal Oxide Polymeric Lightning Arresters
5kv 10kv 10ka Composite Silicon Rubber Surge Arresters with Kema
3kv Polymeric Housed Zinc Oxide Lightning Arresters
Line Equipment 3-60kv Surge Arrestors in Hangzhou Fuyang
10ka (3-36KV) Polymer Housed Lightning Arrester
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters