3.1 Strain clamp
3.18.1 Design

Bolted dead-end strain clamps, clevis type, minimum breaking load 70kN, all ferrous parts to be hot-dip galvanized. Suitable for conductor diameter 5 – 14mm complying with the following standards.
 
DIN 48215 Clamps and connectors for overhead power line
IEC 60228 Conductors of insulated cables
BS 6360 Specification for conductors in insulated cables
BS 03288 Insulator and conductor fittings for overhead power lines
 
3.18.2. Material
The parts of the clamps shall be manufactured from materials, which withstand the mechanical loads and environmental circumstances. All ferrous parts shall be hot-dip galvanized.
Each clamp shall be marked with the name or trademark of the manufacturer. The markings shall be legible and durable.
3.18.3. Testing
Type and sample tests shall be as per the relevant standard including;
Verification of dimensions
Mechanical test
Electrical test
Galvanizing test

3.1 Stay rod for MV

3.17.1 Standard
Any Standard which fits our design requirements is acceptable.
3.17.2. Material
* To protect corrosion stay rod shall be well hot dip-galvanized.
3.17.3 Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.17.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

Stay rod for LV

3.16.1 Standard
Any Standard which fits our design requirements is acceptable.
3.16.2. Material
* To protect corrosion stay rod shall be well hot dip-galvanized.
3.16.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.16.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

3.1  Stay plate for MV
3.15.1 Standard
Any Standard which fits our design requirements is acceptable.
3.15.2. Material
* To protect corrosion stay plate shall be well hot dip-galvanized.
3.15.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.15.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

3.1  Stay plate for LV
3.14.1 Standard
Any Standard which fits our design requirements is acceptable.
3.14.2. Material
* To protect corrosion stay plate shall be well hot dip-galvanized.
3.14.3 Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
3.14.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection.
           c.    Galvanizing test

     M16, 400mm long bolt nut and washer 
3.12.1. Standard
BS 4190 or equivalent is acceptable.
3.12.2. Design
Long bolt nominal diameter (d) 16 mm and lead 2.
Minor threaded diameter (dk) 14mm.
Thickness of head (k) as per BS standard
The nut shall fit long bolt threaded diameter.
Thickness of nut head (m) as per BS standard
Width of head across flats (s) as per BS standard.
Width of head across angle (e) as per BS standard
Washer diameter (d1) as per BS standard.
Thickness of washer as per BS standard.
Inside diameter of washer (h) as per  BS standard
To protect corrosion long bolt shall be well hot dip-galvanized.
3.12.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of long bolt shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.12.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

3.1   M16, 300mm long bolt nut and washer 
3.11.1 Standard
BS 4190 or equivalent is acceptable.
3.11.2 Design
Long bolt nominal diameter (d) 16 mm and lead 2.
Minor threaded diameter (dk) 14mm.
Thickness of head (k) as per BS standard
The nut shall fit long bolt threaded diameter.
Thickness of nut head (m) as per BS standard
Width of head across flats (s) as per BS standard.
Width of head across angle (e) as per BS standard
Washer diameter (d1) as per BS standard.
Thickness of washer as per BS standard.
Inside diameter of washer (h) as per  BS standard
To protect corrosion long bolt shall be well hot dip-galvanized.
3.11.3. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of long bolt shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.11.4 Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

3.1 Earthing Rod with Clamp
Profiled earthing rods of hot dip galvanized steel with connecting lugs. Cross-section and length of profile shall be 50x50x3 mm and 3 m long, respectively. The earthing rod should also be in accordance with the corresponding drawing of this tender.
Earthing rod clamps suitable for stranded copper conductor of 25-35 mm2.
 
3.10.1 Guaranteed Value
 
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Each and every dimension according to the given drawing.
 
3.10.2. Testing
 
The following testing shall be carried out.
 
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

 Standard :BS or equivalent is acceptable.
 Design
– Small collar nominal diameter (d) 12 mm and lead 2.
– Minor threaded diameter (dk) 10mm.
– Thickness of head (k) as per BS standard
– The nut shall fit small collar threaded diameter.
– Thickness of nut head (m) as per BS standard
– Width of head across flats (s) as per BS standard.
– Width of head across angle (e) as per BS standard
– Washer diameter (d1) as per BS standard.
– Thickness of washer as per BS standard.
– Inside diameter of washer (h) as per  BS standard
To protect corrosion small collar shall be well hot dip-galvanized.
3.13.3 Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of small collar shall be according to the design dimension.
* Each and every dimension according to the given drawing.
3.13.4. Testing
The following testing shall be carried out.
           a.   Visual inspection
           b. Size inspection
           c.   Galvanizing test
 Big collar, type 2
Standard

BS or equivalent is acceptable.
 Design
– Big collar nominal diameter (d) 16 mm and lead 2.
– Minor threaded diameter (dk) 14mm.
– Thickness of head (k) as per BS standard
– The nut shall fit big collar threaded diameter.
– Thickness of nut head (m) as per BS standard
– Width of head across flats (s) as per BS standard.
– Width of head across angle (e) as per BS standard
– Washer diameter (d1) as per BS standard.
– Thickness of washer as per BS standard.
– Inside diameter of washer (h) as per  BS standard
To protect corrosion big collar shall be well hot dip-galvanized.
. Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
* Threads of big collar shall be according to the design dimension.
* Each and every dimension according to the given drawing.
 Testing
The following testing shall be carried out.
 
           a.   Visual inspection
           b. Size inspection
           c.    Galvanizing test

Tie Strap
The strap shall have a cross section dimension of 50 x 5 mm
The strap shall have a cross section dimension of 50 x 5 mm.
The strap manufactured for suspension/intermediate assembly according to the given drawing (see the drawing)
Yield strength of tie strap must be 240N/mm2.
To protect tie strap from corrosion it shall be hot dip-galvanized.

Guaranteed Value
The following values are guaranteed by the manufacturers as stipulated by the guaranteed characteristics table
§ Each and every dimension
§ Material strength.
3.7.4. Testing
The following testing must be carried out.
a. Visual inspection
b. Size and dimension verification.
 U channel cross-arm for 33kV

Any standard equivalent to GB/T 707 1988, 80×43, 5/8 and 100×48, 5.3/8.5 is accepted.
For suspension, T-off, angle and dead end assembly shall have a cross section dimension of
80 x 43 x 5/8mm
For transformer base U-cross arms shall have a  dimension of 100x48x5.3/8.5
U-cross arms manufactured for suspension, T-off, angle, dead end and transformer base
assembly as per the drawing
To protect U-cross arms against corrosion U-cross arms shall be hot dip-galvanized
Yield strength of U-cross arm 240N/mm2

Test for ultimate tensile strength
 Test for yield stress
 Percentage elongation test
Bend test
 Chemical composition test
 Galvanization tests thickness of  Zn coating
 Weight of Zn Coating
 Uniformity of Zn coating
 Adhesion test of Zn coating
 Visual inspection
Weight verification
 

Dead end hook 382
Hook threaded nominal diameter (A) 16mm
Minor threaded diameter (W) 14
Thickness of nut (M), washer diameter and thickness as per BS standard
Yield strength of pin must be 240N/mm2
LV Hook from corrosion it shall be hot dip-galvanized
Visual inspection
Size inspection
 Galvanizing test
Strength test

Suspension hook M16-380
Hook threaded nominal diameter (A) 16mm
Minor threaded diameter (W) 14
Thickness of nut (M), washer diameter and thickness as per BS standard
Yield strength of pin must be 240N/mm2
To protect LV Hook from corrosion it shall be hot dip-galvanized
Testing

Visual inspection
Size inspection
Galvanizing test
Strength test

The following testing shall be carried out

Dead End Clamp ,Anchoring Clamp

The clamps should be designed to Anchor LV AB cable with insulated messenger. The clamp
should anchor/hold the neutral messenger without damaging the insulation.
The clamp should conform to the standard NFC 33041 and 33042 or equivalent. The clamp
body should be made of corrosion resistant Aluminium alloy, bail should be of stainless steel
and self adjusting wedges should be weather and UV resistant polymer.

Anchoring assemblies are used to firmly attach the messenger of ABC to a support and
transmit the mechanical tension at the end of a run or to the supporting structures at a major
change in direction.
 

neutral messenger should be fixed by an adjustable grip device.
The suspension clamp shall be manufactured from weather and UV light resistant reinforced

nylon and aluminum alloy. The clamp should provide an additional insulation between the
cable and the pole.
Clamps should be fixed with pole by eyehook/bracket. Breaking load should not be less than
15kN
Suspension Assembly is used for supporting an ABC by installation on the messenger at an

intermediate point of support such as a pole. It can accommodate small angles of deviation up
to 30o. The clamp should hold insulated messenger of diameter range from 6mm up to 12 mm.
Visual examination
Dimensional and material verification
Tensile strength
Dielectric voltage test
Climatic & corrosion ageing
Endurance test under mechanical and thermal stresses
Electrical ageing
 

TYPE:APG-C4
NAME:Parallel groove clamp APG-C4
Specification
 

Material
 
   
Material standard
 
   
Range of conductor cross-section
 
16…50/2.5…35
 
 
Range of conductor diameter, Al/Cu
 
mm2
 
 
Tensile strength
 
KN 5
Thickness of zinc coating,
 
mm
 
43
Test voltage at 50Hz for one minute in water
 
kV
 
6

  Al 35-300mm²     Size 105*65mm  Tri-bolts  Bolt M10*60  Weight 560g

We are China Strain Clamp 70kn 5-14mm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Anchoring Clamp Products

Plastic Tension Clamp for ADSS Cable

Tension Clamp Strain Clamp Anchoring Clamp Tension Connector

Stainless Tension Clamp Aerial Power Fittings Anchor Clamp

M16, 300mm Long Bolt Nut and Washer

Hot Selling Acadss ADSS Clamp

Small Collar 50*8

Popular jgtrade1 Products

High -Voltage Isolate Switch 35kv 6000A

Fuseholder, 200 AMPS, 15kv, 110kv Bil, Chance Cat

Multi Tight Line Device (iron)

Load Break Switch Fuse Disconnector 36kv 200A

"K" and "T" Type Fuse Link

Yh10W-21, 21kv 10ka Surge Arrester

Popular Stay Rod Products

Power Fittings: Stay Rod(Stay Set)

Hot-DIP Galvanized Stay Rod Stay Assembly Accessories Fastener Power Fittings

Stay Rod Equipment and Binding Accessories

Bow Stay Rod Bsr-Z18/180

Turnbuckle Stay Rod Tsr18X2440

High Quality Anchorrod Adjustable Turnbuckle Stay Rod

Popular Strain Clamp Products

Strain Clamps Straight Type NLZ-1L

High Quality Bolted Type Strain Clamp

Tension Clamps/Aluminum Anchoring Clamps for Lines

Nut Wedge Type Adiustable Strain Clamp

L&R Aluminum Alloy Tension Clamp

Aluminium Alloy Suspension Clamp Csg-3

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION