Stranded Bare Aluminum Overhead Conductor AAC
Stranded Bare Aluminum Overhead Conductor AAC image
Get Latest Price Request a quote
Quick Details
Product Details
Standard
ASTM B231: Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B230: Standard Specification for Aluminum 1350-H19 Wire for Electrical Purposes
Application
This stranded bare overhead conductor AAC is used in high voltage overhead power transmission lines. Compared with ACSR of the same diameter, it has a smaller breaking load and is used in lines where short span and low resistance are required.
Product Details
1) Conductor: stranded 1350 aluminum
2) Sectional area: 10~1250 mm2
3) No. of strands: 7, 19, 37, 61, 91, 127
4) Aluminum wire performance
| Diameter | Min tensile strength (MPa) | Min. elongation (%) | ||
| mm | Average | Individual | Average | Individual |
| 0.227~1.25 | 170 | 160 | … | … |
| 1.26~1.50 | 200 | 185 | 1.4 | 1.2 |
| 1.51~1.75 | 195 | 185 | 1.5 | 1.3 |
| 1.76~2.00 | 195 | 185 | 1.6 | 1.4 |
| 2.01~2.25 | 190 | 180 | 1.6 | 1.5 |
| 2.26~2.50 | 185 | 175 | 1.6 | 1.5 |
| 2.51~2.75 | 180 | 170 | 1.6 | 1.5 |
| 2.76~3.00 | 175 | 165 | 1.7 | 1.6 |
| 3.01~3.50 | 170 | 160 | 1.8 | 1.7 |
| 3.51~3.75 | 170 | 160 | 1.9 | 1.8 |
| 3.76~4.50 | 165 | 160 | 2.0 | 1.9 |
| 4.51~5.25 | 165 | 160 | 2.1 | 2.0 |
| 5.26~6.50 | 160 | 155 | 2.3 | 2.2 |
5) AAC conductor specification
| Code | Area (AWG/MCM) |
Stranding (No./mm) |
Overall Dia. (mm) |
Approx. Weight (kg/km) |
Min. Breaking Load (kN) |
Max. DC Resist. @ 20ºC (Ω/km) |
| Peachbell | 6 | 7/1.55 | 4.67 | 37 | 2.49 | 2.1692 |
| Rose | 4 | 7/1.96 | 5.89 | 58 | 3.96 | 1.3624 |
| Iris | 2 | 7/2.47 | 7.42 | 93 | 5.97 | 0.8577 |
| Pansy | 1 | 7/2.78 | 8.33 | 117 | 7.32 | 0.6801 |
| Poppy | 1/0 | 7/3.12 | 9.36 | 147 | 8.73 | 0.539 |
| Aster | 2/0 | 7/3.50 | 10.51 | 186 | 11.0 | 0.4276 |
| Phlox | 3/0 | 7/3.93 | 11.80 | 234 | 13.47 | 0.3390 |
| Oxlip | 4/0 | 7/4.42 | 13.26 | 296 | 16.98 | 0.2688 |
| Valerian | 250 | 19/2.91 | 14.57 | 349 | 20.62 | 0.2275 |
| Sneezewort | 250 | 7/4.80 | 14.40 | 349 | 20.07 | 0.2275 |
| Laurel | 266.8 | 19/3.01 | 15.05 | 373 | 22.00 | 0.2133 |
| Daisy | 266.8 | 7/4.96 | 14.90 | 373 | 21.41 | 0.2133 |
| Peony | 300 | 19/3.19 | 15.97 | 419 | 24.03 | 0.1896 |
| Tulip | 336.4 | 19/3.38 | 16.91 | 470 | 26.95 | 0.1691 |
| Daffodil | 350 | 19/3.45 | 17.24 | 489 | 28.04 | 0.1625 |
| Canna | 397.5 | 19/3.67 | 18.36 | 555 | 31.84 | 0.1431 |
| Goldentuft | 450 | 19/3.91 | 19.55 | 629 | 34.99 | 0.1264 |
| Syringa | 477 | 37/2.88 | 20.19 | 666 | 38.49 | 0.1193 |
| Cosmos | 477 | 19/4.02 | 20.12 | 666 | 37.08 | 0.1193 |
| Hyacinth | 500 | 37/2.95 | 20.65 | 698 | 40.35 | 0.1138 |
| Zinnia | 500 | 19/4.12 | 20.60 | 698 | 38.88 | 0.1138 |
| Dahlia | 556.5 | 19/4.35 | 21.73 | 777 | 43.27 | 0.1022 |
| Mistiletoe | 556.5 | 37/3.11 | 21.79 | 777 | 43.62 | 0.1022 |
| Meadowsweet | 600 | 37/3.23 | 22.63 | 838 | 47.03 | 0.0948 |
| Orchid | 636 | 37/3.33 | 23.31 | 888 | 49.85 | 0.0894 |
| Heuchera | 650 | 37/3.37 | 23.56 | 908 | 50.95 | 0.0875 |
| Flag | 700 | 61/2.72 | 24.48 | 978 | 51.46 | 0.0813 |
| Verbena | 700 | 37/3.49 | 24.45 | 978 | 54.87 | 0.0813 |
| Nasturtium | 715.5 | 61/2.75 | 24.76 | 1000 | 58.74 | 0.0795 |
| Violet | 715.5 | 37/3.53 | 24.74 | 1000 | 56.09 | 0.0795 |
| Cattail | 750 | 61/2.82 | 25.35 | 1048 | 59.85 | 0.0795 |
| Petunia | 750 | 37/3.62 | 25.32 | 1048 | 5875 | 0.0795 |
| Lilac | 795 | 61/2.90 | 26.11 | 1111 | 63.45 | 0.0715 |
| Arbutus | 795 | 37/3.72 | 26.06 | 1111 | 6232 | 0.0715 |
| Snapdragon | 900 | 61/3.09 | 27.78 | 1257 | 69.78 | 0.0632 |
| Cockscomb | 900 | 37/3.96 | 27.73 | 1257 | 68.48 | 0.0632 |
| Goldenrod | 954 | 61/3.18 | 28.60 | 1333 | 78.96 | 0.0596 |
| Magnolia | 954 | 37/4.08 | 28.55 | 1333 | 72.58 | 0.0596 |
| Camellia | 1000 | 61/3.25 | 29.36 | 1397 | 77.53 | 0.0569 |
| Hawkweed | 1000 | 37/4.18 | 29.23 | 1397 | 76.08 | 0.0569 |
| Larkspur | 1033.5 | 61/3.31 | 29.76 | 1444 | 80.12 | 0.0550 |
| Bluebell | 1033.5 | 37/4.24 | 29.72 | 1444 | 78.63 | 0.0550 |
| Marigold | 1113 | 61/3.43 | 30.89 | 1555 | 86.28 | 0.0511 |
| Hawthorn | 1192.5 | 61/3.55 | 31.05 | 1666 | 92.45 | 0.0477 |
| Narcissus | 1272 | 61/3.67 | 33.02 | 1777 | 98.61 | 0.0477 |
| Columbine | 1351.5 | 61/3.78 | 34.01 | 1888 | 104.78 | 0.0421 |
| Carnation | 1431 | 61/3.89 | 35.03 | 1999 | 107.68 | 0.0398 |
| Gladiolus | 1510.5 | 61/4.00 | 35.09 | 2110 | 113.65 | 0.0376 |
| Coreopsis | 1590 | 61/4.10 | 36.51 | 2221 | 119.64 | 0.0358 |
| Jessamine | 1750 | 61/4.30 | 38.72 | 2445 | 131.68 | 0.0325 |
| Cowslip | 2000 | 91/3.76 | 41.40 | 2791 | 153.00 | 0.0285 |
| Lupine | 2500 | 91/4.21 | 46.30 | 3524 | 187.00 | 0.0230 |
| Trillium | 3000 | 127/3.90 | 50.75 | 4232 | 225.00 | 0.0192 |
| Bluebonnet | 3500 | 127/4.21 | 54.80 | 4985 | 262.00 | 0.0166 |
Packaging details
| Polyethylene film packaging 1) Usually used for cables with an overall diameter 10mm and below 2) 100 meters per roll or as per customer’s requirements 3) Packaging dimension: 50cm * 50cm * 20cm or below 4) Weight: 30 kg/roll or below |
Steel-wood drum packaging 1) Used for cables with a overall diameter of 10mm and above 2) Drum size: 180cm * 180cm *110cm (different sizes are available according to packaging length) 3) Standard length: as per customer’s requirements. |
Customer service
1) Select the right cable as per customer’s requirements
2) Design suitable packaging to guarantee safe and the most economic delivery
3) Provide installation and use guidance
4) Product quality guarantee under the normal use
Company Information
We are China Stranded Bare Aluminum Overhead Conductor AAC manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Overhead Conductor Products
AAC Bare Aluminum Overhead Conductor
AAC Bare Aluminum Overhead Conductor for Overhead Transmission
Bare Conductor Aluminum Conductors, Aluminum Steel Reinforced Conductor
Aluminum Overhead Conductor, AAC, AAAC, ACSR Conductors Manufacturer
Popular Overhead Conductor Products
ACSR Bare Conductor Used in Power Transmission
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Rook
USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Chickadee
Aluminum Conductor Steel Reinforced AAC AAAC ACSR Overhead Conductor
Overhead ASTM Standard Bare All Aluminum Conductor (AAC, AAAC, ACSR)
AAC Bare Aluminum Overhead Conductor
Popular Overhead Conductor AAC Products
Popular zzjinshui Products
Aerial Bundle Cable / ABC Cable with PE or XLPE Insulation
High Quality Overhead Bare Conductor AAC 70mm2 for Sale
110kv XLPE Power Cable for Heavy Duty
0.6/1kv Cu Conductor PVC Isnulation Aluminum Tape PVC Power Cable
Al/XLPE 3X16+16mm2 3X25 Quadruplex ABC Cable
Tags: Aluminum Overhead Conductor, Overhead Conductor, Overhead Conductor AAC, zzjinshui