The Copper Conductors Type 0.6 Kv Electrical Cable 16 Sq mm 300mm
The Copper Conductors Type 0.6 Kv Electrical Cable 16 Sq mm 300mm image
Get Latest Price Request a quote
Quick Details
Product Details
The copper conductors type 0.6 KV electrical Cable 16 sq mm 300mm
Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction:
Conductor: | annealed copper or of plain aluminium or aluminium alloy | |
Insulation: | XLPE / PVC material | |
Armour: |
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request. | |
Sheath: | PVC compound | |
sheath colour: | black |
Technical data:
Temperature range: | |
during installation: | -5 °C up to +50 °C |
fixed installed: | -30 °C up to +70 °C |
at short circuit of max. 5 s: | up to 160 °C |
Nominal voltage: | Uο/U = 0,6/1 kV |
Test voltage: | 4 kV |
Max. operating voltage in three-phase systems: | 1,2 kV |
Maximal tensile strength: | 50 N/mm² |
Behaviour in fire: | IEC 60332-1 |
Minimal inner bending radius: | |
single core: | 15D |
multi core: | 12D |
Dimensions:
Single core(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
1×1.5 | 1.4 | 0.7 | 1.4 | 5.6 |
1×2.5 | 1.8 | 0.7 | 1.4 | 6.0 |
1×4 | 2.3 | 0.7 | 1.4 | 6.5 |
1×6 | 2.8 | 0.7 | 1.4 | 7.0 |
1×10 | 3.6 | 0.7 | 1.4 | 7.8 |
1×16 | 4.5 | 0.7 | 1.4 | 8.7 |
1×25 | 5.6 | 0.9 | 1.4 | 10.2 |
1×35 | 6.7 | 0.9 | 1.4 | 11.3 |
1×50 | 8.0 | 1 | 1.4 | 12.8 |
1×70 | 9.4 | 1.1 | 1.4 | 14.4 |
1×95 | 11.0 | 1.1 | 1.5 | 16.1 |
1×120 | 12.4 | 1.2 | 1.5 | 17.8 |
1×150 | 13.8 | 1.4 | 1.6 | 19.8 |
1×185 | 15.3 | 1.6 | 1.6 | 21.8 |
1×240 | 17.5 | 1.7 | 1.7 | 24.4 |
1×300 | 19.5 | 1.8 | 1.8 | 26.7 |
1×400 | 22.6 | 2 | 1.9 | 30.5 |
1×500 | 25.2 | 2.2 | 2.0 | 33.7 |
1×630 | 28.3 | 2.4 | 2.2 | 37.4 |
1×800 | 31.9 | 2.6 | 2.3 | 41.7 |
1×1000 | 35.7 | 2.8 | 2.4 | 46.2 |
Two cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.8 | 9.2 |
2×2.5 | 1.8 | 0.7 | 1.8 | 10.0 |
2×4 | 2.3 | 0.7 | 1.8 | 11.0 |
2×6 | 2.8 | 0.7 | 1.8 | 12.0 |
2×10 | 3.6 | 0.7 | 1.8 | 13.6 |
2×16 | 4.5 | 0.7 | 1.8 | 15.4 |
2×25 | 5.6 | 0.9 | 1.8 | 18.4 |
2×35 | 6.7 | 0.9 | 1.8 | 20.6 |
2×50 | 8.0 | 1 | 1.8 | 23.6 |
2×70 | 9.4 | 1.1 | 1.8 | 26.8 |
2×95 | 11.0 | 1.1 | 1.9 | 30.2 |
2×120 | 12.4 | 1.2 | 2.0 | 33.7 |
2×150 | 13.8 | 1.4 | 2.2 | 37.5 |
2×185 | 15.3 | 1.6 | 2.3 | 41.6 |
2×240 | 17.5 | 1.7 | 2.5 | 46.7 |
2×300 | 19.5 | 1.8 | 2.6 | 51.4 |
2×400 | 22.6 | 2 | 2.9 | 58.9 |
Three cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.8 | 9.6 |
3×2.5 | 1.8 | 0.7 | 1.8 | 10.5 |
3×4 | 2.3 | 0.7 | 1.8 | 11.6 |
3×6 | 2.8 | 0.7 | 1.8 | 12.6 |
3×10 | 3.6 | 0.7 | 1.8 | 14.4 |
3×16 | 4.5 | 0.7 | 1.8 | 16.3 |
3×25 | 5.6 | 0.9 | 1.8 | 19.5 |
3×35 | 6.7 | 0.9 | 1.8 | 21.9 |
3×50 | 8.0 | 1 | 1.8 | 25.1 |
3×70 | 9.4 | 1.1 | 1.9 | 28.7 |
3×95 | 11.0 | 1.1 | 2.0 | 32.4 |
3×120 | 12.4 | 1.2 | 2.1 | 36.1 |
3×150 | 13.8 | 1.4 | 2.3 | 40.3 |
3×185 | 15.3 | 1.6 | 2.4 | 44.6 |
3×240 | 17.5 | 1.7 | 2.6 | 50.2 |
3×300 | 19.5 | 1.8 | 2.7 | 55.2 |
3×400 | 22.6 | 2 | 3.0 | 63.3 |
Three cores+1(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
---|---|---|---|---|---|---|
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1.8 | 17.5 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1.8 | 21.2 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1.8 | 23.8 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1.8 | 27.5 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 2.0 | 31.7 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 2.1 | 35.8 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 2.3 | 39.9 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 2.4 | 44.6 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 2.6 | 49.5 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 2.8 | 55.7 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 3.0 | 61.4 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 3.2 | 70.4 |
Four cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.8 | 10.4 |
4×2.5 | 1.8 | 0.7 | 1.8 | 11.3 |
4×4 | 2.3 | 0.7 | 1.8 | 12.5 |
4×6 | 2.8 | 0.7 | 1.8 | 13.7 |
4×10 | 3.6 | 0.7 | 1.8 | 15.7 |
4×16 | 4.5 | 0.7 | 1.8 | 17.8 |
4×25 | 5.6 | 0.9 | 1.8 | 21.5 |
4×35 | 6.7 | 0.9 | 1.8 | 24.1 |
4×50 | 8.0 | 1 | 1.8 | 27.8 |
4×70 | 9.4 | 1.1 | 2.0 | 32.0 |
4×95 | 11.0 | 1.1 | 2.1 | 36.1 |
4×120 | 12.4 | 1.2 | 2.3 | 40.2 |
4×150 | 13.8 | 1.4 | 2.4 | 44.9 |
4×185 | 15.3 | 1.6 | 2.6 | 49.8 |
4×240 | 17.5 | 1.7 | 2.8 | 56.0 |
4×300 | 19.5 | 1.8 | 3.0 | 61.7 |
4×400 | 22.6 | 2 | 3.2 | 70.7 |
Multi-cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
5×1.5 | 1.4 | 0.7 | 1.8 | 11.2 |
7×1.5 | 1.4 | 0.7 | 1.8 | 12.0 |
10×1.5 | 1.4 | 0.7 | 1.8 | 14.8 |
12×1.5 | 1.4 | 0.7 | 1.8 | 15.2 |
14×1.5 | 1.4 | 0.7 | 1.8 | 16.0 |
19×1.5 | 1.4 | 0.7 | 1.8 | 17.6 |
21×1.5 | 1.4 | 0.7 | 1.8 | 18.4 |
24×1.5 | 1.4 | 0.7 | 1.8 | 20.4 |
30×1.5 | 1.4 | 0.7 | 1.8 | 21.6 |
40×1.5 | 1.4 | 0.7 | 1.8 | 26.0 |
48×1.5 | 1.4 | 0.7 | 1.8 | 26.4 |
61×1.5 | 1.4 | 0.7 | 1.9 | 29.0 |
5×2.5 | 1.8 | 0.7 | 1.8 | 12.2 |
7×2.5 | 1.8 | 0.7 | 1.8 | 13.2 |
10×2.5 | 1.8 | 0.7 | 1.8 | 16.4 |
12×2.5 | 1.8 | 0.7 | 1.8 | 16.9 |
14×2.5 | 1.8 | 0.7 | 1.8 | 17.7 |
19×2.5 | 1.8 | 0.7 | 1.8 | 19.6 |
21×2.5 | 1.8 | 0.7 | 1.8 | 20.6 |
24×2.5 | 1.8 | 0.7 | 1.8 | 22.8 |
30×2.5 | 1.8 | 0.7 | 1.8 | 24.1 |
40×2.5 | 1.8 | 0.7 | 1.9 | 29.4 |
48×2.5 | 1.8 | 0.7 | 1.9 | 29.9 |
61×2.5 | 1.8 | 0.7 | 2.0 | 32.8 |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length.
COMPANY INFORMATION:
For more information and inquiry, pls contact me without any hesitation.
We are China The Copper Conductors Type 0.6 Kv Electrical Cable 16 Sq mm 300mm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 16mm XLPE Cable Products
Popular Cable Products
240mm2 0.6/1 Kv XLPE Insulated Cable
450/750V Copper Conductor PVC Insulated Copper Wire Braided Control Cable
Power Cable 70mm2 120mm Low Voltage
BS3242 Standard 90mcm Bare Aluminum Alloy Electric Wire Cable Overhead Bare AAAC Conductor
Strain Clamp Jmac 16/2 Strain Clamp Jmac 16/2
Popular Copper Cable Products
Flexible Copper Conductor Welding Cable
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Manufacture 2 Core Cable 0.75mm PVC Flexible Cable Power Cable
Mv Voltage XLPE Insulated Swa Armoured Electric Cable, Power Cable
0.6/1kv PVC Insulated Steel Tape Armored Flame Retardant Power Cable
Popular zzhongdacable Products
N2xs2y Na2xs2y 6/10kv 18/30kv Medium Voltage Cable with XLPE Insulation
AAC Aluminum Conductor Poppy 7 Strand 1/0AWG Open Wire
400V Power Cables 3 Phase 4 Core Cable 25mm for Myanmar
Power Cable Vvg Avvg Avvgng Avvgng-Ls 2X1.5 Cable for 0.66, 1 and 3 Kv
ABC Aerial Bundled AS/NZS 3599.2 6.35/11kv ABC Cable (AL/XLPE/HDPE)
33kv Cable Single Core Al XLPE Awa 1X630mm2 Aluminum Cable
Tags: 16mm XLPE Cable, Cable, Copper Cable, zzhongdacable