Turn-Buckles Cat

China 
                        Turn-Buckles Cat
                      manufacture and supplier

Turn-Buckles Cat image

Get Latest Price Request a quote

Quick Details

Turn-Buckles Cat

Pull-Line Fitting

Substation Fittings, Line Fittings

OEIpower

Cartons Pallets Wooden Case

IEC IEEE

China Nanyang

7318150000

Product Details

Diameter and Take Up Inches (mm) Closed Coupling length Inches (mm) Weight
Lb (kg)
12 (304.8) 23.6 (599) 5.43 (2.46)

Turnbuckles are used as adjustable extension links to maintain proper tower clearance on assemblies at tower end.
Jaw ends are supplied with bolt, nut, and humpback cotter pin.

Material: Body  galvanized forged steel
Cotter Pin – stainless steel

The Composite Insulators 

Ball socket B11A

The Composite Insulators comply with the latest editions of and amendments to, the standards/specification listed below:
 
CSA                                CANADIAN STANDARDS ASSOCIATION
 
G164-4                       –      Hot dip galvanizing of Irregular Shaped Articles
 
CAN/CSA                 –      Quality Assurance Program Categories 2299.3
 
ANSI                          –     AMERICAN NATIONAL STANDARDS INSTITUTE
 
C29.1                          –     American Standard Test Method For Electrical Power Insulators
 
C29.7                          –     American Standard For Wet-processed Porcelain Insulators (High Voltage Line Post Type) Electrical Power Insulators
 
987-1985                    –      IEEE Guide For Application of Composite Insulators
 
D750                           –     Recommended Practice for Operating Light and Weather Exposure Apparatus (Carbon Arc Type) For Artificial Weather Testing Of Rubber Compounds.
 
D1499                         –     Recommended Practice For Exposure of Plastics.
 
D2240                         –     Rubber Properties, Durometer Hardness
 
D2565                         –     Recommended Practice For Operating Xenon-Arc Light And Water Exposure Apparatus Plastics.
The weathershed of the Post Insulators shall be manufactured from either Hydrated Alumina Ethylene Propylene Copolymer (EPM) as the primary constituent or Silicone Elastomers. The weathershead shall be injection moulded and brought to final cure state in one continuous process to prevent internal undercure or surface overcure. Additionally, the weathershead shall provide hydrophobic surface, even after exposure to tropical marine environment, ultra violent rays and moisture.
Core

 
The rod or the core is manufactured from Fibreglass, having 70-75 by weight of auxiliary aligned glass fibre bonded by an organic resin. The rod is either be cast or pultruded.
The end fittings are have the following properties:
 

i.         are compressed onto the Fibreglass rod member
ii.        are  not move relative to the central Fibreglass rod at applied loads equal to two times the rated Routine Test Load or maximum designed cantilever loads
iii.       are attracted to the rod after completion of all external heat processes used to cure or bond component parts.
 
The insulator are  provided load limiting bases that will deform under longitudinal loading of more than 100% of the rated design cantilever load. 
Performance Characteristics
 
The Polymeric Insulators are meet the under listed performance characteristics.
 

 
           ITEM
 
              11kV
 
              33KV
 
Dry Flashover Withstand
 
              90kV     
 
              180kV
 
Wet flashover withstand
 
              70kV
 
              165kV
 
Positive Impulse Critical flashover
 
             145kV
 
               300kV
 
Maximum Radio Interference Voltage
 
Below 1micro volt
 
  Below 1 micro volt        
 
Design Tension Strength
 
              100kN
 
               100kN
 
Residual Strength after Power Arc
 
                80kN
 
                80kN
 
Mechanical Proof Test Load
 
               45kN
 
                 45kN
 
Maximum Sustained Load
 
               34kN
 
                 34kN
 
Design Torque Rating
 
              83 Nm
 
                 83 Nm

 
 

The insulator are suitable for accepting both aluminium and copper conductors having cross-sectional areas ranging from 35mm2 to 265mm2. The insulators are designed for mounting on the angle and channel crossarms specified in Specification E14
 
All exposed ferrous part shall be treated against corrosion. Treatment by hot dip galvanizing is preferable.
 
 

DIMENSIONS
A 110mm D1 18mm
D 70mm T 5mm
E 32mm L 100mm
F 40mm D2 12mm
View More  

Not exactly what you want?

Post Sourcing Request

Hot Searches

Socket Pin
High Voltage Ceramic
Voltage Insulator
Rubber Insulator
Composite Insulator
Silicon Insulator
View More 

We are China Turn-Buckles Cat manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Ball Socket Products

Ball Socket

Al-Cu Transition Connectors Type Syg, Compression Type, Group C

Popular jgtrade1 Products

15kv Porcelain Lightning Arrester Bushing

Clevis Tongues Type Zs

Lightning Electricity Testing Earthing Ring (Piercing / Non-piercing)

Tubular Bus-Bar Joints Type Mj, Inside

Weight for Each Part:

Ball Socket

Popular Porcelain Insulator Products

ANSI 53-5 Spool Insulators /Linear Insulator/Porcelain Insulator for High Voltage

Porcelain Pin Insulator Ceramic Insulator Line Post 33kv 5kn 10kn

Overhead Line Transmission Line ANSI 57-1 Series Porcelain Line Post Insulator

IEC C10-325-III High Voltage Ceramic/Porcelianstation Post Insulator

Shf-10g Pin Ceramic Insulator for Kazakhstan Johnson Ceramic Insulator Factory

IEC C6-250 Ceramic/ Porcelain Station Post Insulator

Popular Tension Type: Products

Ball Socket

Al-Cu Transition Connectors Type Syg, Compression Type, Group C

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION